AC voltage test with a nominal frequency of 50 Hz for 10 minutes between conductors for power cables with alternating voltage he:3500 thousand m³
AC voltage test with nominal frequency of 50 Hz for 10 minutes between conductors for power cables with alternating head:3000 thousand m³
Rated AC voltage of flexible and power cables:660...1000 thousand m³
Rated AC control voltage:660 thousand m³
More from REZHKA-BEL
Fire-Resistant Control Cable KVBbShvng(A)-LS for Safety Applications
$0.90-$3.60
Telephone Communication Cable KTAПВT with Copper Wires
$0.90-$3.60
Low Smoke Flame Retardant Power Cable VBSHvng(A)-LS
$0.90-$4.20
Low Smoke Zero Halogen Control Cable KVVGzng(A)-LS
$0.60-$3.60
Signal and Locking Cable with Polyethylene Insulation, Model: [Insert Model Code]
$0.90-$3.60
Multi-core Signal and Locking Cable, SBMVBepPBbShp
$0.90-$3.60
Signal and Locking Cables with Polyethylene Insulation and Hydrophobic Filling, m
$0.90-$6
Multi-Core Thermoelectric Cable KMTVng(A)-LS
$0.90-$3.60
Low Smoke Non-Combustible Control Cable KVBbShvzng(A)-LS
$0.90-$3.60
Industrial Automation Cable KUMP-OEBsng(A)-FRLS
$0.90-$6
Signal and Locking Cable with Enhanced Electromagnetic Protection
$9-$42
Thermoelectric Multi-Core Cable with Single-Conducting Wires, KMTVEVT
$0.90-$6
Description
Cable control fire-resistant with copper conductive cores with cross-section from 0,75 to 10,0 mm2, with the number of cores from 3 to 61, with a thermal barrier of mica-containing tapes, with a common screen of alumoflex, with insulation and sheathing of polyvinylchloride plastic not spreading combustion in group laying, with reduced smoke and gas emission. Designed to extend the electrodes of thermocouples and their connection to measuring devices; and cables designed for the transmission and distribution of electrical energy and electrical signals in stationary electrical installations, at rated AC voltage of 380, 660 and 1000 V frequency 50Hz or at DC voltage of 500, 1000 and 1500V respectively.
KRUINv-(M)RpEmfzng(A)-FRHF Cable - U* (1-37) x (2, 3, 4) x (0.2-2.5)
$0.90-$3.60 USD
Rated operating voltage:
1000
Operating temperature:
-50...85
LLC "NPO "PZSK" 🇷🇺
Fire-Resistant Cable KPSng(A)-FRHF for Safe Wiring Solutions
$0.90-$3.60 USD
Working capacity:
5500000000
Test voltage between conductors:
1
ENTE LLC 🇷🇺
Fire-Resistant Low Smoke Zero Halogen Cable up to 1kV VVGng(A)-FRLS
$1.80-$7.20 USD
Permissible heating temperatures of cable cores:
long-term permissible - not more than 70°?; in overload mode - not more than 90°?; short-circuit limit - 160°?; under the condition of short-circuit non-fire - not more than 350°?.
Installation conditions:
Cables may be laid without limitation of level difference along the route of laying, including vertical sections. Permissible tension forces of cables during laying shall not exceed 50 N/mm2. The permissible bending radius of multicore cables during laying
GOSTKABEL LLC 🇷🇺
Flexible Armored Fire-Resistant Data Transmission Cable KPIGSKng(A)-FRLS