Output voltage range
380...720 V
Voltage of supplying traction (T) network
300...720 V
Alternating (P) current distribution network supply voltage
340...420 V
AC mains frequency
SBVVBG
Output current range
10...500 A
Output current setting accuracy
10 %
efficiency, at least
95 %
Minimum utilised energy capacity (UEC) of BTA, not less
70000
BTA charging mode
continuous
Rated voltage of control circuits, heating, cooling converters, ventilation grille drives, lighting and signalling circuits, vol
220 V
Network frequency of control circuits, heating, cooling converters, ventilation grille drives, lighting and external lighting
SBVVBG
Rated voltage of automatic circuits, direct current
24 V
Rated voltage of current and voltage sensor circuits, direct current
15 V
Rated voltage of fire alarm circuits, direct current
B1/B8 2100/900 MHz V
ZS control scheme
Microprocessor
Climatic version and placement category
U1
Operating limits of ambient air temperature
-40...40 °C
Permissible height of operation of the sounder
up to 1500 m above sea level
Degree of protection
IP54, IK-10
Facing material for centre console and support
stainless steel
Overall dimensions of the support with contact dome
depending on the location of the zs
Height between the contact surface of the contact tyre and the carriageway, mm
4600 +/-100
Weight, not more
18000 kg
?????????????? ???-500?(?)
joint
Current transmitting device
Schunk SLS 101
ZSE-500T(P) electric bus communication system
communication channel via PLC standard ISO 15118
Backup communication channel ZSE-500T(P) with electric bus
Wi-Fi
Communication with higher level systems
2 GSM channels, Modbus TCP
Ventilation system
Available
Fire extinguishing system
availability
Protection against lightning
available
Service life, at least
15 year