Purpose: power supply with intrinsically safe circuits for sensors located in intrinsically hazardous area GOST R 51330.10 (IEC 60079-11-99), GOST 30852.10-2002 (IEC 60079-11-99)Type of explosion protection: intrinsically safe electric circuit of level "ib "Explosion protection marking:[Exib]IExplosive mixtures:according to GOST 30852.11-2002 categories I, IIA, IIB/IIC ExibIIBPower supply voltage: 18-35VPower consumption: 4WOutput voltage: 9VLoad current:up to 170mAGalvanic isolation: 3000VProtections: against incorrect connection of the polarity of the power supplyTemperature:Operating temperature range from -40C to +70CShell protection degree: IP20 (GOST 14254-2015)Design:slot designMounting: on DIN-railDimensions (HxWxG): 109x22.5x113 mmMass: not more than 0.2 kgFailure rate: 100 000 hService life:20 yearsWarranty: 18 months