The purpose of electrical training is to provide a load equal to or less than the maximum permissible load during operation, or to provide such equivalent test conditions that allow the maximum number of potentially unreliable products in the tested batch to be identified in a short time.
Features:
Designed for electrical training of vacuum devices such as travelling wave lamps (VWL).
It allows simultaneous training of up to six devices.
It is equipped with a multi-level protection system against electric shock.
It has a load equivalent for periodic control of the stand output parameters.
TECHNICAL DATA
2.1 General information
2.1.1 The number of items to be trained simultaneously is six.
2.1.2 Warm-up time of the system before the start of operation not less than 30 minutes.
2.1.3 The system provides continuous operation mode for 16 hours with a subsequent break of at least 8 hours.
2.1.4 The system is powered from a single-phase AC mains voltage...