Digital Multifunction Power Quality Measurement Device - SHM Model

Digital Multifunction Power Quality Measurement Device - SHM Model

Brand: ShchMK
$600 - $3,000 USD
MOQ: 2 pieces

Key Features

Overall dimensions, mm: 120?120?93 (without protective cover), 120?120?103 (with cover)
Average MTBF: 250000 ?
Power quality parameters: Voltage short-circuit; positive voltage deviation; negative voltage deviation; frequency; frequency deviation; short-term flicker dose; long-term flicker dose; voltage n-harmonic coefficient up to 50th order; summaries
Weight, kg, not more: 0,7

Description

The ShchMK120S device is designed for measurement, control and registration of the main parameters of electrical energy up to the 50th harmonic in single-phase two-wire and three-phase three-wire and four-wire electrical networks and AC power supply systems with a nominal frequency of 50 Hz; measurement, registration and metering of active and reactive electrical energy for specified time intervals in three-phase AC networks (including technical and commercial metering of active and reactive electricity) in accordance with the requirements of the Russian Federation State Register of Measuring Instruments No. 617-16-16.
ShchMK120S is included in the State Register of measuring instruments of the Russian Federation No. 60431-15. Interverification interval - 10 years.

Specifications

Overall dimensions, mm
120?120?93 (without protective cover), 120?120?103 (with cover)
Average MTBF
250000 ?
Power quality parameters
Voltage short-circuit; positive voltage deviation; negative voltage deviation; frequency; frequency deviation; short-term flicker dose; long-term flicker dose; voltage n-harmonic coefficient up to 50th order; summaries
Weight, kg, not more
0,7
LED indication
3 blocks of seven-segment indicators (4 indicators per block); single LED indicators for displaying units of measurement, distinctive indices and signs of displayed parameters; sign height: 20 mm; seven-segment indicators for displaying the current state o
Input signal
1 A, 5 A, I/1 A, I/5 A, 100 V, 400 V, U/100 V; voltage rating: 57.73/230 V - phase, 100/400 V - interphase; input measurement frequency: 42.5 to 57.5 Hz
Measurement time
0.2 sec (current and voltage), 1 sec (frequency)
Commercial electricity metering
Active energy received/released/summed at 8 tariffs; reactive energy received/released/summed/ by r-th quadrant (r = 1, 2, 3, 4) at 8 tariffs
Compliance of PCE measurements with the established Russian standards
GOST 30804.4.30-2013 ; GOST 32144-2013 ; GOST 30804.4.7-2013 (Class I) ; GOST R 51317.4.15-2012 ; GOST R 8.655-2009 ; GOST R 8.689-2009
Compliance with requirements for active and reactive energy meters
GOST 31819.22-2012 (Class 0,2S); GOST 31819.23-2012 (Class 1); GOST 31818.11-2012; GOST IEC 61107-2011
Galvanic isolation on the power supply circuit (main or backup) and on the input circuits
Got it
RS485 communication interface
Quantity: 2; protocols: Modbus RTU, IEC 60870-5-101 Interface exchange rate: 200, 300, 600, 1200, 1200, 2400, 4800, 4800, 9600, 19200, 38400, 57600, 115200 bits/sec.
Ethernet communication interface
Quantity: 2; Ethernet 10/100BASE-TX (RJ45 connector) or Ethernet 100BASE-FX (ST connector) Protocols: IEC 60870-5-104, Modbus TCP, IEC 61850-8-1 (MMS), IEC 61850-9-2 (SV) - optional
Remote human-machine interface
HTTP (embedded web interface) with access by device IP address
Integration into the system of control of power quality indicators
HTTP (integration into the software package for visualization and control of power quality indicators supplied with the device)
Integration into external systems: telemetering, telemechanics, automated process control systems, SM&KE, ASCUE
IEC 60870-5-104, IEC 61850-8-1 (MMS), Modbus TCP, IEC 60870-5-101, Modbus RTU
Time synchronization
NTP (RFC 5905)/PTP (IEEE `1588); clock error is not more than ±1 sec. per day; in the absence of external power supply, the clock can operate for at least 15 days.
Event logs
System event log - up to 1000 events with automatic overwriting of earlier events when the maximum is reached; power quality event log - up to 100 thousand events with automatic overwriting of earlier events when the maximum is reached.
Storage of measurement results
In the internal non-volatile memory of measured PCE values; cyclic buffer for storing profiles of all values with a storage depth of at least 90 days (2160 hours) with automatic overwriting of earlier records after the free space is exhausted.
Electricity test protocol
In accordance with GOST 32144-2013 for any time interval not less than 90 days.
Power supply voltage
Main: 220VU (from 90 to 264 V AC with frequency (50 ± 0.5) Hz or from 130 to 370 V DC); standby ("RESERVE"): 220VU (90 to 264 VAC with a frequency of (50 ± 0.5) Hz or 130 to 370 VDC)
Power consumption from the power supply circuit, not more
10 V?A (full power) when powered by 50 Hz single-phase AC power supply, 10 W when powered by DC power supply
Reprogramming
Via "Configurator" programme (RS485, Ethernet interface), via web-interface
Operating temperature range
-40 to +55 °C (relative humidity 90% at +30 °C)
Degree of protection
IP51
Resistance to mechanical influences
Group 4 according to GOST 22261-94
Industrial noise level
GOST 30805.22-2013 for class A equipment
Inspection interval
10 years
Warranty period of operation
36 mos.
Average service life, at least
30 years

Related Products

Multifunctional Measuring Converter ENIP-2 Modification 04

Multifunctional Measuring Converter ENIP-2 Modification 04

$300-$1,800 USD
Measurement range of AC current, % of Inom: 1...200
Voltage measurement range, % of Unom: 5...150
Energoservis Engineering Center LLC 🇷🇺
Power Meter for Continuous and Pulsed Signals M3-104

Power Meter for Continuous and Pulsed Signals M3-104

$900-$3,000 USD
Power, not more: 25
Frunze OJSC 🇷🇺
Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-20/50

Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-20/50

$150-$540 USD
Measured power range: ATT OFF: 10 nW ... 10 mW; ATT ON: 100 µW ... 20 W
Frequency range of measured power: 300 kHz ... 3 GHz
RTS LLC 🇷🇺
Waveguide Thermistor Wattmeter M3-122 for RF Power Measurement

Waveguide Thermistor Wattmeter M3-122 for RF Power Measurement

$900-$3,600 USD
Operating frequency range: 16.7...37.5
Time to establish operating mode: 30
VNIIFTRI SUE 🇷🇺
Average Power Meter M3-106 for Continuous and Pulsed Signals

Average Power Meter M3-106 for Continuous and Pulsed Signals

$900-$3,000 USD
Power, not more: 60
Frunze OJSC 🇷🇺
Power Meter M3M-18 for Measuring Continuous Microwave Signals

Power Meter M3M-18 for Measuring Continuous Microwave Signals

$900-$3,000 USD
Maximum value of the frequency range: 18
Maximum value of the frequency range: 18
MICRAN OJSC 🇷🇺
Digital Power Measurement Device for AC Current SHV02.1

Digital Power Measurement Device for AC Current SHV02.1

$90-$300 USD
Overall dimensions, mm: 96x48x148 (with protective cover), 96x48x121,5 (without cover)
Overall dimensions, mm: 96x48x148 (with protective cover), 96x48x121,5 (without cover)
ELECTROPRIBOR OJSC 🇷🇺
Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-100/50

Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-100/50

$270-$780 USD
Measured power range: ATT OFF: 10 nW ... 10 mW; ATT ON: 100 µW ... 100 W
Frequency range of measured power: 300 kHz ... 3 GHz
RTS LLC 🇷🇺
Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-500/50

Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-500/50

$600-$1,800 USD
Measured power range: ATT OFF:10 nW ... 10 mW; ATT ON: 300 kHz ... 2 GHz
Power measurement error: ATT OFF from 5 %; ATT ON from 8 %
RTS LLC 🇷🇺
Multifunctional Volt-Amperes-Phase Meter VFM-4

Multifunctional Volt-Amperes-Phase Meter VFM-4

$900-$3,000 USD
AC current measurement range: Up to 1000 A
AC and DC voltage measurement range: Up to 700 V
CHELENERGOINSTRUMENT LLC 🇷🇺
Power Meters for Absorbed Power M3-105

Power Meters for Absorbed Power M3-105

$900-$3,000 USD
Power, not more: 40
Frunze OJSC 🇷🇺
Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-1500/50

Power Meter for Absorbed Power M3-1-1500 "Narcissus", Modification M3-1500/50

$900-$3,000 USD
Measured power range: ATT OFF: 10 nW ... 10 mW; ATT ON: 10 mW ... 1500 W
Frequency range of measured power: ATT OFF: 300 kHz ... 3 GHz; ATT ON: 300 kHz ... 1.4 GHz
RTS LLC 🇷🇺
Digital Power Measurement Device for AC Current SHV96.1

Digital Power Measurement Device for AC Current SHV96.1

$90-$300 USD
Input signal: 0,5 A; 1 A; 2,5 A; 5 A; 100 V, 380 (400) V. Connection via 100V voltage transformer or 1A, 5A current transformer is possible.
Input signal: 0,5 A; 1 A; 2,5 A; 5 A; 100 V, 380 (400) V. Connection via 100V voltage transformer or 1A, 5A current transformer is possible.
ELECTROPRIBOR OJSC 🇷🇺
Digital Power Meter for AC Measurement SHV72.1

Digital Power Meter for AC Measurement SHV72.1

$90-$300 USD
Overall dimensions, mm: 72x72x103 (with protective cover), 72x72x75,6 (without cover)
Overall dimensions, mm: 72x72x103 (with protective cover), 72x72x75,6 (without cover)
ELECTROPRIBOR OJSC 🇷🇺
Power Meter for Absorbed Power PLS50-05M

Power Meter for Absorbed Power PLS50-05M

$900-$3,000 USD
Operating frequency range: 50...50000
Connector type: Output connector: type 2.4 mm (plug)
MICRAN OJSC 🇷🇺
Three-Phase Active and Reactive Power Measuring Converter E849

Three-Phase Active and Reactive Power Measuring Converter E849

$15-$48 USD
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
Mounting: possibility of mounting on t-rail tn-35-7;5 according to iec 60715-2013 or directly on the panel
ALEKTO-ELECTRONICS LLC 🇷🇺
Voltage, Current, and Power Measurement Converters for Three-Phase Electric Networks FE1892-AD

Voltage, Current, and Power Measurement Converters for Three-Phase Electric Networks FE1892-AD

$90-$300 USD
Type of primary transducer (PT): no
Type of primary transducer (PT): no
VIBRATOR OJSC 🇷🇺
Unified Thermistor Power Meter M3-121

Unified Thermistor Power Meter M3-121

$900-$3,000 USD
Time to establish operating mode: 15
Continuous operation time: 8
VNIIFTRI SUE 🇷🇺
Power Meter for Absorbed Power PLS26-03M

Power Meter for Absorbed Power PLS26-03M

$420-$1,200 USD
Frequency range: 50...26500
Connector type: Output connector: type IX, var 3 (plug)
MICRAN OJSC 🇷🇺
Energy Quality Measurement Device - Energomonitor 3.3T1

Energy Quality Measurement Device - Energomonitor 3.3T1

$900-$3,000 USD
Phase voltage measuring range: 6...360
Display: Available
MARS-ENERGO LLC 🇷🇺