Signal input module for load cells NL-1SGPurpose:for measuring signals of bridge strain gaugesConnection:1 analogue input with the possibility of connection (four or six-wire circuit) up to 6 sensors connected in parallel with resistance not less than 350 Ohm at excitation voltage 10 VExcitation setting:software setting of strain gauge excitation voltage, in the range of 0 to 10 V with a discreteness of 1 mVVVoltage and current rangesVoltage and current ranges:seven (7) input software switchable ranges: six for voltage 15 mV, 50 mV, 100 mV, 500 mV, 1 V, 2.5 V and one for current 20 mAnalogue inputs: 1 analogue output, voltage output range 0-10 V, maximum output current 170 mAdiscrete inputs:4 discrete outputs based on 35 V 0.75 A/channel smart keys and two discrete dry contact or TTL inputsGalvanic isolation:Galvanic isolation strength with respect to power supply and RS-485 interface:...