Length of warranty period
12 months from shipping date.
Waste class according to SanPiN 2.1.7.2790-10
A and B.
Software security class
B
Characteristics of a dedicated medical LCD monitor
Anti-glare coating; user-adjustable monitor settings (brightness, contrast); screen size diagonal of at least 21.5 inches; resolution of at least 1980x1080 pixels; frame rate 60 Hz; viewing angle: 120° left/right; 90° up/down
Characteristics of the touchmonitor
Number of pixels - 1280 x 800; 10.1-inch LCD monitor (with LED backlight, hereinafter referred to).
External signal connections (ports)
hdmi (output); usb (for connecting peripheral usb devices); network connector (for connecting to a local area network lan, patient data can be transferred to other servers via dicom); s-vhs (output for connecting s-vhs video recorder); audio output; port
Working part type
Ultrasound sensors - type BF; ECG leads - type CF with defibrillation protection.
Physiological signal detection channel
Input voltage range from 0.2 to 5 mV; input impedance not less than 10 MΩ.
Number of tricks
1-4 focuses
Maximum scanning depth
38 cm
Adjusting the signal gain
overall and 1 - 8 zones
When operating in the Doppler spectrum mode, ensuring simultaneous audio playback in the selected resolution strobe
Available.
Dynamic range of received signals
from 30 to 256 dB
Power adjustment
from 2 to 100 %
Performing a self-test to verify operation at power-on
available
Mode of operation
Продолжительный (более 8-ми часов).
Time to establish operating mode
less than 3 minutes.
Degree of safety for use in the presence of flammable anesthetics with air, oxygen or nitrous oxide
not intended
Sound power level generated by the system
does not exceed 55 dB
Protection against electric shock
class I
Rated power consumption value
620
Rated mains frequency
SBVVBG
Rated mains voltage
220 V
Operating conditions
from 10 to 35°C and relative humidity not more than 80% at 25°C
Storage conditions
In storage rooms at a temperature from -50 to 40 °C and relative humidity not exceeding 75% at 15 °C.
Transportation conditions
From -50 to 50 °C, relative humidity 75% at 15 °C in covered vehicles: by road up to 1000 km; by rail up to 10000 km; by plane, in heated sealed compartments.
Climatic version according to GOST R 50444
UHL 4.2
Resistance to mechanical effects during operation according to GOST R 50444
group 2
Rated mains voltage
220 V
Potential consumer
medical treatment and preventive care institutions
Scope of application
examination of abdominal organs; heart examination; gynecological examination; musculoskeletal system examination; obstetric examinations; pediatric examinations; small organ examination; transcranial Doppler; urological
Echogram generation modes
2D mode; M-mode; Color M-mode; Anatomical mode; Color Doppler mode (CD); Pulsed-wave spectral Doppler mode (PW); Continuous-wave Doppler mode (CW); Tissue Doppler mapping mode (TDM); Tissue pulse mode