1
Request Details
2
Contact Info

What do you need?

Describe the product or service you are looking for

Your Contact Information

We will contact you as soon as possible

Request Submitted!

Thank you! We will contact you soon with the best offers.

Optical-Electronic Linear Smoke Detector IPD-75CMD

Optical-Electronic Linear Smoke Detector IPD-75CMD

$90 - $300 USD
MOQ: 20 pieces

Key Features

Range of possible distances between the transceiver and the reflector-reflector: 8...120 m
Maximum possible width of the area to be protected by one detector: 9 m
Maximum possible room area protected by one detector: 1080 mile
Detector supply voltage: 10...30 thousand m³

Description

Linear smoke detector for the protection of premises of large area or length. Distinctive features of this modification: single-position design (transceiver + reflector-reflector); working distance from 8 to 60, to 80, to 100, to 120 metres; accurate screw alignment mechanism.

IP212-75SMD - single-position linear fire detector, consisting of a transceiver and reflector-reflector. In the transceiver, the optical channels are separated and isolated in a two-chamber optical system.

As a reflector-reflector in IP212-75SMD a highly effective cataphone (retroreflector) is used, which is able to fulfil its functions even if its surface is deflected relative to the optical beam by 10 - 15 degrees. On the sides of the transceiver housing under the mounting covers are located terminal blocks for external connections, software switch tactics detector and connection connector tester IPDL-75.

Specifications

Range of possible distances between the transceiver and the reflector-reflector
8...120 m
Maximum possible width of the area to be protected by one detector
9 m
Maximum possible room area protected by one detector
1080 mile
Detector supply voltage
10...30 thousand m³
Current consumed by the detector in the "Normal" mode, not more than
0.001
Current consumed by the detector in the "Attention" signaling mode, max.
0.01
Current consumed by the detector in the "Fire" signal generation mode, not more than
0.035
Current consumed by the detector in the "Fault" signaling mode, not more than
0.001
Current surge value at formation of the output signal "Attention"
0.005...0.006
Maximum possible duration of interruptions or polarity reversals of the supply voltage that do not affect normal operation
100 visit
Minimum permissible power interruption interval frequency
4
Minimum required duration of power failure to ensure resetting of recorded notifications
2 -
Typical inertia of detector operation (for "Attention" and "Fire" signals)
5 -
Maximum inertia of detector actuation (by signals "Attention" and "Fire")
10 -
Inertia of "Fault" notification fixation in the "Fault - memory" mode
3...5 -
Inertia of "Fault" notification fixation in the "Fault - tolerance" mode
3...5 -
Inertia of "Fault" notification fixation in the "Fault - Beam" mode
6.5...7.5 -
Inertia of "Fault" notification fixation in the "Fault - excess" mode
40...60 -
Inertia of "Fault" notification fixation in the "Fault - Reduction" mode
40...60 -
Weight of the transceiver, not more than
0.42 m² living area
Weight of a standard reflector-reflector, not more than
0.45 m² living area
Weight of the reduced reflector-reflector, not more than
0.07 m² living area
Weight of the remote device UV-PPD-PRM, not more than
0.04 m² living area
Degree of protection of the shell according to GOST 14254, IP
54

Related Products

Addressable Optical-Electronic Smoke Detector IP 212-64-R3

Addressable Optical-Electronic Smoke Detector IP 212-64-R3

$9-$30 USD
Operating temperature range: -20...55
Housing material: ABS
RUBEZH LLC 🇷🇺
Aspirating Smoke and Heat Fire Detector IPA v4

Aspirating Smoke and Heat Fire Detector IPA v4

$180-$600 USD
Dimensions: 211x237x99
Operating temperature: -20...+55
CJSC "PO "SPETSAVTOMATIKA" 🇷🇺
Optical-Electronic Linear Smoke Detector IP212-75Ex-Yastreb

Optical-Electronic Linear Smoke Detector IP212-75Ex-Yastreb

$90-$300 USD
Maximum possible room area protected by one detector: 900
Range of possible distances between the transceiver and the reflector-reflector: 8...100
IVS LLC 🇷🇺
Optical-Electronic Linear Addressable Smoke Detector IP212-C6500-XX

Optical-Electronic Linear Addressable Smoke Detector IP212-C6500-XX

$90-$300 USD
Maximum possible room area protected by one detector: 1080
Range of possible distances between the transceiver and the reflector-reflector: 8...120
IVS LLC 🇷🇺
Non-addressable Smoke Fire Detector IP 212-78 Aurora-DN

Non-addressable Smoke Fire Detector IP 212-78 Aurora-DN

$3-$18 USD
Average service life of the device: 10
Average MTBF of the device: At least 60,000 hrs.
ARGUS-SPEKTR LLC 🇷🇺
Optical-Electronic Addressable Smoke Detector IP 212-149

Optical-Electronic Addressable Smoke Detector IP 212-149

$9-$30 USD
Operating temperature range: -10...70
Housing material: ABS
RUBEZH LLC 🇷🇺
Optical-Electronic Addressable Smoke Fire Detector IП 212-149

Optical-Electronic Addressable Smoke Fire Detector IП 212-149

$9-$30 USD
Operating temperature range: -10...70
Degree of protection: IP40
KB POZHARNOY AVTOMATIKI LLC 🇷🇺
Optical-Electronic Linear Addressable Smoke Detector IP 212-118 Amur-I Model L

Optical-Electronic Linear Addressable Smoke Detector IP 212-118 Amur-I Model L

$15-$48 USD
Overall dimensions: 275x160x102
Operating range: 10...100
ARGUS-SPEKTR LLC 🇷🇺
Optical-electronic smoke fire detector A3DPI without base

Optical-electronic smoke fire detector A3DPI without base

$9-$30 USD
Operating temperature range: -40...60
Power supply: From the addressable loop
RISPA LLC 🇷🇺
Optical-Electronic Smoke Detector, Ex-proof Model IP 212-116.2 Trion MK

Optical-Electronic Smoke Detector, Ex-proof Model IP 212-116.2 Trion MK

$15-$48 USD
Operating temperature range: -40...+75
Supply voltage range: 10-30?
CMD LLC 🇷🇺
Optical-Electronic Point Smoke Detector IP 212-116 Trion VZ

Optical-Electronic Point Smoke Detector IP 212-116 Trion VZ

$9-$36 USD
Operating temperature range: -40...+75
Degree of protection of the shell: IP31/IP67
CMD LLC 🇷🇺
Addressable Analog Optical-Electronic Smoke Detector IP 212-108 MAX

Addressable Analog Optical-Electronic Smoke Detector IP 212-108 MAX

$9-$30 USD
Detector sensitivity: 0.05-0.2 dB/m
Protection degree of the detector shell: IP40
UNIMAX LLC 🇷🇺
Heat Detector for Fire Alarm Systems RUBETEK IP 101-102-A1R/Wh

Heat Detector for Fire Alarm Systems RUBETEK IP 101-102-A1R/Wh

$9-$30 USD
Overall dimensions, mm: 92x42
Operating temperature range: -25...55
RUBETEK RUS LLC 🇷🇺
Optical-Electronic Point Smoke Detector A2DPI Model 08

Optical-Electronic Point Smoke Detector A2DPI Model 08

$9-$30 USD
Power supply: From the addressable loop
Power supply: From the addressable loop
RISPA LLC 🇷🇺
Optical-Electronic Linear Addressable Smoke Detector IP 212-118/2 SPK-MAX-DL

Optical-Electronic Linear Addressable Smoke Detector IP 212-118/2 SPK-MAX-DL

$90-$300 USD
Average MTBF of the device: At least 60,000 hrs.
Overall dimensions of the unit (Transmitter and Receiver Unit): 270x160x105
ARGUS-SPEKTR LLC 🇷🇺
Combined Optical-Electronic Heat Smoke Fire Detector IP 212/1

Combined Optical-Electronic Heat Smoke Fire Detector IP 212/1

$9-$30 USD
Operating temperature range: -35...55
Detector operating temperature: 54...70
RUBEZH LLC 🇷🇺
Optical-Electronic Smoke Fire Detector IP 212-01

Optical-Electronic Smoke Fire Detector IP 212-01

$9-$36 USD
Diameter: 120
Height: 40
ZAVOD PRIBOROV LLC 🇷🇺
Maximal Differential Addressable Analog Heat Fire Detector IP 101-80/4-A1R SPK-MAX-T

Maximal Differential Addressable Analog Heat Fire Detector IP 101-80/4-A1R SPK-MAX-T

$15-$48 USD
Diameter: 107
Height: 47
ARGUS-SPEKTR LLC 🇷🇺
Optical-Electronic Smoke Detector IP 212-189A

Optical-Electronic Smoke Detector IP 212-189A

$3-$18 USD
Detector diameter: 85
Detector height: 48
ELEMENT LLC 🇷🇺
Wireless Heat Detector IP 101-3-PR (RO-R ASPZ) for Fire Alarm Systems

Wireless Heat Detector IP 101-3-PR (RO-R ASPZ) for Fire Alarm Systems

$150-$480 USD
Overall dimensions: 85 x 212 x 44 mm
Operating temperature: -20...60
SPBEX-MINING LLC 🇷🇺
Request via WhatsApp