Range of possible distances between receiver and transmitter
8...140 m
Maximum possible width of the space to be protected by one detector
9 m
Maximum possible room area protected by one detector
1260 mile
Detector power supply voltage (receiver and transmitter)
10...30 thousand m³
Current consumed by the detector in the "Normal" mode (when the transmitter is powered from the receiver via communication line)
0.0025
Current consumed by the receiver in the "Normal" mode (when the transmitter is powered from a separate source), not more than
0.0025
Current consumed by the transmitter when powered from a separate source (in any mode of operation), not more
0.0012
Current consumed by the receiver in the mode of forming the output signal "Attention", not more than
0.011
Current consumed by the receiver in the mode of forming the output signal "Fire", not more than
0.04
Current consumed by the receiver in the mode of forming the output signal "Fault", not more than
0.011
Current surge value at formation of the output signal "Attention"
0.00675...0.00825
Maximum possible duration of interruptions or polarity reversals of the supply voltage that do not affect normal operation
0.1 -
Minimum permissible power interruption interval frequency
4
Minimum required duration of power cut-off to ensure resetting of recorded notifications.
2 -
Typical inertia of detector operation (for "Attention" and "Fire" signals)
5 -
Maximum inertia of detector actuation (by signals "Attention" and "Fire")
10 -
Inertia of "Fault" notification fixation in the "Fault - memory" mode
3...5 -
Inertia of "Fault" notification fixation in the "Fault - tolerance" mode
3...5 -
Inertia of "Fault" notification fixation in the "Fault - Beam" mode
1.5...2.5 -
Inertia of "Fault" notification fixation in the "Fault - synchronization" mode
40...70 -
Inertia of "Fault" notification fixation in the "Fault - failure" mode
40...70 -
Inertia of "Fault" notification fixation in the "Fault - excess" mode
40...70 -
Inertia of "Fault" notification fixation in the "Fault - Reduction" mode
40...70 -
Typical value of resistance of closed contacts of optorelay outputs
15 yd³
Maximum value of resistance of closed contacts of optorelay outputs
25 yd³
Resistance value of open contacts of optorelay outputs, not less than
500000 yd³
Isolation resistance value of output optorelay circuits from detector power supply circuits, not less than
500000 yd³
Maximum permissible current value switched by the optorelay outputs
0.1
Maximum permissible voltage value switched by optorelay outputs .
100 thousand m³
Maximum permissible value of wire resistance of the communication line between the receiver and the transmitter
220 yd³
Weight of the receiver and transmitter separately, not more than
0.42 m² living area
Degree of protection of the shell according to GOST 14254, IP
40