MPA-KD Gas Fire Suppression Modules (50-XX-33)

MPA-KD Gas Fire Suppression Modules (50-XX-33)

Brand: Brandsis
$180 - $1,800 USD
MOQ: 5 pieces

Key Features

Minimum pressure in the module at which it remains operable: 1 thous. t storage
Test pressure: 7.5 thous. t storage
LPS actuation pressure range: 6.37...7.35 thous. t storage
The mass of GOTV that remains in the module after its actuation, not more than: 0.3 m² living area

Description

Modules of gas fire extinguishing MPA-KD (50-XX-33) for working pressure of 5,0 MPa are manufactured according to technical conditions TU 28.29.22-009-09214033-2018 revision 2. The modules use: Brandsys 0421 (DN 33 mm) with electromagnetic, pneumatic and/or manual starting methods with cylinders with capacity from 6 litres to 150 litres: MPA-KD (50-6-33); MPA-KD (50-8-33); MPA-KD (50-10-33); MPA-KD (50-16-33); MPA-KD (50-20-33); MPA-KD (50-25-33); MPA-KD (50-28-33); MPA-KD (50-32-33); MPA-CD (50-51-33); MPA-CD (50-52-33); MPA-CD (50-81-33); MPA-CD (50-106-33); MPA-CD (50-142-33); MPA-CD (50-147-33); MPA-CD (50-150-33).

Modules correspond to climatic execution UHL, placement category 4 according to GOST 15150-69, in the temperature range from minus 20 C to plus 50 ?. Modules meet the requirements for seismic resistance, strength and resistance to external influencing factors.

Modules are certified for use with GOTV Brandsis 1230 (FK-5-1-12), Chladon 227.

Specifications

Minimum pressure in the module at which it remains operable
1 thous. t storage
Test pressure
7.5 thous. t storage
LPS actuation pressure range
6.37...7.35 thous. t storage
The mass of GOTV that remains in the module after its actuation, not more than
0.3 m² living area
Equivalent length of the module, not more
3.7 m
Module pneumatic start pressure (minimum/maximum)
0.8...6.4 thous. t storage
Diameter of the nominal bore of the plug-in module/siphon tube
33 mm
Operating pressure (maximum at +50C) of the module
5 thous. t storage
Mechanical (manual) start-up force of the module on the safety lock (hand force on the handle), not more than
150 thousand ct

Related Products

Gas Fire Extinguishing System UGP Eol 2P025

Gas Fire Extinguishing System UGP Eol 2P025

$90-$300 USD
Overall dimensions: L 192, D 76
Overall dimensions: L 192, D 76
SPT LLC 🇷🇺
CO2 Fire Suppression Gas Module M06 (150-100-16)

CO2 Fire Suppression Gas Module M06 (150-100-16)

$1,500-$4,800 USD
Module working pressure: 150
Cylinder capacity nominal: 100
PGA-ENGINEERING LLC 🇷🇺
Gas Fire Suppression Module MGPT 65-60-50-E-01-A eF5.887.004-26

Gas Fire Suppression Module MGPT 65-60-50-E-01-A eF5.887.004-26

$900-$3,000 USD
Cylinder capacity: 60?
Cylinder capacity: 60?
PJSC TENSOR 🇷🇺
Gas Fire Suppression Module ZARYA-22 (30-22.5-18)

Gas Fire Suppression Module ZARYA-22 (30-22.5-18)

$90-$300 USD
Vessel capacity: 22.5
Working pressure of GOTV in the vessel (at ambient temperature 20±2 °C), MPa (kgf/cm2), when filling with hladon 125, hladon 227: 1,6 (16)
ISP LLC 🇷🇺
CO2 Discharge Ramp for Three Cylinders PRU-3

CO2 Discharge Ramp for Three Cylinders PRU-3

$900-$3,000 USD
Highest inlet gas pressure: 20
Highest operating gas pressure at the reducer outlet: 0...15
SPTG LLC 🇷🇺
Gas Fire Extinguishing System UGP Eol 3A100

Gas Fire Extinguishing System UGP Eol 3A100

$90-$300 USD
Overall dimensions: L 386, D 89
Overall dimensions: L 386, D 89
SPT LLC 🇷🇺
Gas Fire Suppression Modules MGP-35

Gas Fire Suppression Modules MGP-35

$900-$3,000 USD
Operating pressure, MPa: 6.4...14.7
Diameter of nominal passage, mm: Built-in memory card slot, support microSD/SDHC/SDXC card (up to 256GB); manual recording/alarm recording
ARTSOK OJSC 🇷🇺
Gas Fire Suppression System UGP Eol 3R100

Gas Fire Suppression System UGP Eol 3R100

$90-$300 USD
Overall dimensions: L 328, D 89
Overall dimensions: L 328, D 89
SPT LLC 🇷🇺
High-Pressure Carbon Dioxide Discharge Ramp for Two Cylinders RRU-2

High-Pressure Carbon Dioxide Discharge Ramp for Two Cylinders RRU-2

$180-$720 USD
Highest inlet gas pressure: 20
Highest operating gas pressure at the reducer outlet: 0...15
SPTG LLC 🇷🇺
Automatic Gas Fire Suppression Modules (Halon 125HP, Halon 227ea, Novec 1230)

Automatic Gas Fire Suppression Modules (Halon 125HP, Halon 227ea, Novec 1230)

$900-$3,600 USD
Cylinder capacity: 100
Working pressure: 6.37
APS LLC 🇷🇺
Gas Fire Suppression Modules MPA-ULT

Gas Fire Suppression Modules MPA-ULT

$900-$3,600 USD
Capacity: 180
Working pressure, kgf/cm2: 65
SPECAVTOMATIKA OJSC 🇷🇺
Gas Fire Suppression Modules Type 2MP

Gas Fire Suppression Modules Type 2MP

$900-$3,000 USD
Module capacity: 100
Maximum working pressure of the module, kgf/cm2: 150
SpecialAutomatics CJSC 🇷🇺
Gas Fire Suppression Module MPA-KD 65-XX-50

Gas Fire Suppression Module MPA-KD 65-XX-50

$450-$1,800 USD
Operating pressure (maximum at +50C) of the module: 6.4
LPS actuation pressure range: 7.845...8.826
OSK HOLDING GROUP LLC 🇷🇺
Gas Fire Suppression Module Type 1MP

Gas Fire Suppression Module Type 1MP

$150-$540 USD
Module capacity: 2
Operating temperature range for mobile objects: minus 50 deg. C to plus 60 deg. ?
SpecialAutomatics CJSC 🇷🇺
Gas Fire Suppression Modules MPA-KD (65-XX-33)

Gas Fire Suppression Modules MPA-KD (65-XX-33)

$900-$3,600 USD
Test pressure: 9.8
Minimum pressure in the module at which it remains operable: 1
OSK HOLDING GROUP LLC 🇷🇺
Gas Fire Suppression System UGP Eol 2A025

Gas Fire Suppression System UGP Eol 2A025

$90-$300 USD
Overall dimensions: L 215, D 76
Overall dimensions: L 215, D 76
SPT LLC 🇷🇺
Gas Fire Suppression Modules and Batteries ATAKA MGP and B-MGP

Gas Fire Suppression Modules and Batteries ATAKA MGP and B-MGP

$180-$1,800 USD
Module scope: 2 to 150 litres
Working pressure: 6.5/14.7MPa
TECHNOS - M+ LLC 🇷🇺
Carbon Dioxide Discharge Ramp for Three Cylinders PPU-3-L

Carbon Dioxide Discharge Ramp for Three Cylinders PPU-3-L

$900-$3,000 USD
Highest inlet gas pressure: 20
Highest operating gas pressure at the reducer outlet: 0...15
SPTG LLC 🇷🇺
Gas Fire Suppression Modules MGP-16

Gas Fire Suppression Modules MGP-16

$900-$3,000 USD
Operating pressure, MPa: 14.7...19.6
Diameter of nominal passage, mm: 16
ARTSOK OJSC 🇷🇺
Gas Fire Suppression Modules MPA-NVC1230

Gas Fire Suppression Modules MPA-NVC1230

$150-$840 USD
Capacity: 180
Capacity: 180
POZHTECHNIKA LLC 🇷🇺
Request via WhatsApp