1
Request Details
2
Contact Info
What do you need?

Describe the product or service you are looking for

Your Contact Information

We will contact you as soon as possible

Request Submitted!

Thank you! We will contact you soon with the best offers.

Continuous Patient Monitoring System MAIT-02 "Danko®", TУ 9441002-48262933-2008, Version 3

Continuous Patient Monitoring System MAIT-02 "Danko®", TУ 9441002-48262933-2008, Version 3 — MEDICAL SYSTEMS LLC

Brand: Danko
$900 - $3,000 USD
MOQ: 2 pieces

Key Features

Heart rate (HR) display range, beats/minute: 15...300
Direct current in the patient's circuit flowing through any electrode: no more than 0.1 µA
Screen Color Palette: 24-bit TrueColor
Cuff pressure measurement range: 0...280

Description

Designed for continuous monitoring of patients (adults, children and newborns) who are in critical condition.

It is used in intensive care units, in operating units during anaesthesia, therapeutic and cardiology departments of hospitals of various profiles. It can be used in military medicine, ambulance, disaster medicine.

It has a unique compactness, mobility, low power consumption. Absolutely not tippable from any working position.

High "survivability" in case of accidental fall. It is possible to change the angle of inclination of the monitor, as well as its fixation to a shelf or rack.

It has a convenient window graphic interface with a touch screen. Large digits mode provides readability of physiological parameters at a considerable distance from the monitor.

Quick access buttons on the front panel of the monitor.

The monitor has an optimal combination of price and quality and is designed for all types and levels of medical institutions.

Specifications

Heart rate (HR) display range, beats/minute
15...300
Direct current in the patient's circuit flowing through any electrode
no more than 0.1 µA
Screen Color Palette
24-bit TrueColor
Cuff pressure measurement range
0...280
Temperature measuring range (normalized)
32...42 °C
Temperature display range
25...50 °C
Screen backlighting
LED with adjustable brightness
Heart rate (HR) measurement range, beats/minute
30...240
Heart rate (HR) measurement range (error normalised), beats/min.
30...240
Input voltage range of ECG channel signals, mV
0.1...5
Display range of respiratory rate (RR) by ECG channel (impedance method)
3...150
Accuracy class
Not applicable
length
220 mm
width
260 mm
height
120 mm
type
patient vital signs monitor
Overall dimensions,mm
not more than 260x120x220 mm
Power supply voltage
198...242 V
Electromagnetic compatibility
GOST R IEC 60601-1-2
Defibrillator discharge protection
GOST R IEC 60601-1
Type of working parts (degree of protection of the patient against electric shock when electrodes are applied to the patient)
CF
Electrical safety protection class
class II
Compliance with SAFETY standards
GOST R IEC 60601-1, GOST R IEC 60601-2-49
Computer software that allows the collection, processing, storage and visualization of monitored data,
availability
Integrated electronic help system
available
Displaying the current date and time on the screen
available
Quickly set audible alarm limits using the touch screen without navigating through submenus
available
Virtual AD Quick Start button on the touch screen
available
BP measurement quick start button on the front panel of the device
availability
Screen type
touch TFT LCD
Configuration of monitoring parameters by the user (enabling and disabling measurement channels at the user's choice)
available
Monitoring mode on the screen at least 6 ECG leads simultaneously
availability
Number of displayed curves in standard mode
at least 5
Number of displayed curves in the "large digits" mode
at least 2
Big Digit Mode
available
Saves all settings including operating modes and trends in the monitor memory in case of power failure
available
Blocking the alarm sound for 4 minutes and resuming it after the specified time has elapsed
alarm sound blocking for 4 min and its resumption after the specified time
Prohibitions of audible alarms
available
Visual indication and audible signaling in case of ECG electrode breakage or poor quality electrode placement
available
Visual indication and audible signaling in case of cardiac arrest (asystole) for a time exceeding (5 ± 0.3) s
available
Visual indication and audible signaling in case of measured values of physiological parameters exceeding the set limits
available
Setting the upper and lower alarm limits for all monitored parameters
availability
Permissible absolute error of temperature measurement in the range from 32 to 42 C
-0.2...0.2 °C
Number of temperature measurement channels
2 pcs
Temperature measurement method
thermistor
TRAINING mode for automatic adjustment of the breathing channel to recognize breathing cycles
available
Selecting the breath sampling leads: RF or RL
available
Range of values of variable component of impedance at which pneumogram registration in the range of respiratory frequency is pro
1...10 ohm
Range of basic impedance values at which pneumogram registration is provided in the respiratory rate range from 3 to 9
500...1000 ohm
Changes the vertical size of the PG within the limits (display scale)
1...10
Permissible absolute error of PD measurement
± 2 min-1
Breathing frequency (BF) measurement range by ECG channel (impedance method)
3...90
Displaying the time of the last BP measurement on the screen
available
Display on the screen the remaining time until BP measurement (at the set measurement interval)
available
Display the measurement mode (adult, pediatric, or neonatal) on the monitor screen
available
Continuous BP measurement mode (user selectable)
available
Automatic detection of the inflation level in the cuff (referenced to the previous measurement)
available
Manual neonatal inflation level setting
60...120
Manual inflation level setting in adult mode
100...180
Automatic cuff inflation level setting from 100 to 280 mmHg.
available
Starting the BP meter at any time at the user's initiative
available
Automatic start-up of the BP meter with adjustable time interval between starts of 3, 5, 10, 15, 30 and 60 minutes
available
Relative permissible error of cuff pressure measurement in the range from 150 to 280 mmHg.
-2...2 %
Absolute permissible error of cuff pressure measurement in the range from 20 to 150 mmHg.
-3...3
Measurement of SpO2 and HR at low perfusion levels
available
Audible pulse accompaniment via photoplethysmogram channel (user-activated)
availability
Display of photoplethysmogram with automatic switching of sensitivity.
available
Permissible absolute error of PD measurement
within ± 2 rev/min
Screen size
5
Carrying handle
available
Permissible absolute error of SpO2 measurement in the range of SpO2 values from 50 to 69 %
-3...3 %
Permissible absolute error of SpO2 measurement in the range of SpO2 values from 70 to 100%
-2...2 %
Saturation (SpO2) measurement range
50...100 %
ECG Isolation Stabilization Filter
presence
Using 3 electrodes (R,L,N) without connecting other electrodes to the ECG cable to capture only one ECG lead.
Availability
Removable electrode holders in the ECG cable
available
Selection of the lead for HR calculation: I, II or III.
available
ECG channel protection against defibrillator pulses
availability
ECG QRS complex audio (user-activated)
available
ECG waveform sweep speed
12.5, 25, 50 mm/s
Time for measuring and displaying new HR values
no more than 20 seconds
Permissible absolute error of HR measurement (at R-beat amplitude from 0.2 to 4 mV)
within ± 1 beats/min
ECG signal vertical display scale (sensitivity equivalent)
4 levels: 5, 10, 20, and 40 mm/mV
Output of ECG, PG, FPG curves and measured values of HR, BP, SpO2, HR, HR, HR, , T to a personal computer or central station.
available
Entering, saving patient data (name, ID number, gender, age, bed number, onset and duration of observation), and storing patient
available
Display of values (trends) of measured parameters in tabular form with intervals of 1, 5, 10, 15, 30 or 60 min (optional)
availability
Displaying values (trends) of measured parameters in graphical form
availability
Memorization of values (trends) of measured parameters for at least 24 hours with an interval of 1 minute
available
Setting of alarm limits and alarms for all measured ??????????? causing an alarm condition
available
Displaying a photoplethysmogram (PPG) on the display screen
available
Displaying a pneumogram (PG) on the display screen
available
Display of electrocardiogram (ECG) in six leads (I, II, III, aVR, aVL, aVF) on the display screen
available
Measure and display patient body temperature values (T1 and T2) on two channels
available
Impedance method measurement and display of respiratory rate (RR) values
available
Measurement and display of saturation (SpO2) and heart rate (HR) values by photoplethysmography
available
Measurement and display of non-invasive systolic (CAD), diastolic (DBP) and mean (MAP) blood pressure values
available
Ability to select the lead for ECG HR measurements
available
Measuring and displaying heart rate (HR) values from the ECG
available
Type of backup power supply
built-in batteries
Backup power supply operation in case of external power supply failure
available
Weight (with built-in batteries)
2.5 kg
Weight (without built-in batteries)
1.5 kg
Power consumption of the monitor from AC mains power supply
30
Monitor mount type
screw mounting holes in the electronic unit housing
Mounting the monitor on a shelf, rack, in the car interior
availability
Mechanism for changing the tilt angle of the monitor when mounted on a flat surface
retractable legs
Auxiliary controls (audible alarm blocking, start-stop BP measurement, call up trend view, call up menu of basic functions, call
buttons on front panel
Basic control (all monitor functions)
touchscreen
User Interface
fully graphical, windowed, interactive
Screen resolution
at least 800x480 dots
Housing material
impact-resistant plastic
Electronic unit design
version 3
Design solution
Electronic unit
Age contingent of patients
adults, children, newborns
Monitoring standard
Pulse oximetry, non-invasive blood pressure, electrocardiography, respiratory rate, body temperature

Related Products

Neonatal Ventilator for Newborns SLE 2000

Neonatal Ventilator for Newborns SLE 2000

$9,000-$30,000 USD
Industrial equipment
Factory direct from Russia
UOMZ OJSC 🇷🇺
Baby Nasal Aspirator for Mucus Removal - ROXY-KIDS

Baby Nasal Aspirator for Mucus Removal - ROXY-KIDS

$1.80-$7.20 USD
Industrial equipment
Factory direct from Russia
ROXY LLC 🇷🇺
Oxygen Discharge Ramp for Three Cylinders RPK-3

Oxygen Discharge Ramp for Three Cylinders RPK-3

$450-$1,800 USD
Industrial equipment
Factory direct from Russia
SPTG LLC 🇷🇺
Caduceus Medical Gas Control and Shut-off Device SU-5

Caduceus Medical Gas Control and Shut-off Device SU-5

$450-$1,800 USD
Industrial equipment
Factory direct from Russia
WESTMEDGROUP LLC 🇷🇺
Anesthesia Complex "PHAZA - 23" for Inhalation Anesthesia

Anesthesia Complex "PHAZA - 23" for Inhalation Anesthesia

$15,000-$48,000 USD
Industrial equipment
Factory direct from Russia
UPZ OJSC 🇷🇺
Oxygen Pressure Regulator Caduceus SKO-250

Oxygen Pressure Regulator Caduceus SKO-250

$90-$300 USD
Industrial equipment
Factory direct from Russia
WESTMEDGROUP LLC 🇷🇺
Anesthesia Set KAN for Anesthesiology and Intensive Care

Anesthesia Set KAN for Anesthesiology and Intensive Care

$1,500-$4,800 USD
Industrial equipment
Factory direct from Russia
Energiya LLC 🇷🇺
Respiratory Protection Gear - RIM (PSH-10C) Breathing Apparatus

Respiratory Protection Gear - RIM (PSH-10C) Breathing Apparatus

$90-$300 USD
Industrial equipment
Factory direct from Russia
RIM PLANT LLC 🇷🇺
Oxygen Compressor for Medical and Industrial Use

Oxygen Compressor for Medical and Industrial Use

$15,000-$60,000 USD
Industrial equipment
Factory direct from Russia
TEGAS LLC 🇷🇺
Oxygen Generator for Medical Use - Oxymedic 1500

Oxygen Generator for Medical Use - Oxymedic 1500

$15,000-$48,000 USD
Industrial equipment
Factory direct from Russia
ONHS LLC 🇷🇺
Infant-NPCP Pneumatic Drive Manual Ventilation Device

Infant-NPCP Pneumatic Drive Manual Ventilation Device

$900-$3,000 USD
Industrial equipment
Factory direct from Russia
AO "NPCAP" 🇷🇺
Medical Oxygen Concentrator "Provita 330" - Adsorption Technology

Medical Oxygen Concentrator "Provita 330" - Adsorption Technology

$15,000-$48,000 USD
Industrial equipment
Factory direct from Russia
PROVITA LLC 🇷🇺
Autonomous Compressed Air Breathing Apparatus "Fenist

Autonomous Compressed Air Breathing Apparatus "Fenist

$150-$540 USD
Industrial equipment
Factory direct from Russia
ELINA-T LLC 🇷🇺
SLE 5000 Neonatal Ventilator for Lung Support

SLE 5000 Neonatal Ventilator for Lung Support

$9,000-$30,000 USD
Industrial equipment
Factory direct from Russia
UOMZ OJSC 🇷🇺
Centralized Oxygen Supply Station KSS-2

Centralized Oxygen Supply Station KSS-2

$1,500-$4,800 USD
Industrial equipment
Factory direct from Russia
RESPIRATOR OJSC 🇷🇺
Medical Respirator for Respiratory Protection FFP1 NR D Model 1010

Medical Respirator for Respiratory Protection FFP1 NR D Model 1010

$0.15-$0.60 USD
Industrial equipment
Factory direct from Russia
FARMSERVICE LLC 🇷🇺
Ultrasonic Inhaler Vulkan-3

Ultrasonic Inhaler Vulkan-3

$150-$480 USD
Industrial equipment
Factory direct from Russia
UKBP OJSC 🇷🇺
Ultrasonic Inhaler Musson-2-03

Ultrasonic Inhaler Musson-2-03

$15-$48 USD
Industrial equipment
Factory direct from Russia
Almaz OJSC 🇷🇺
Inhalational Anesthesia Machine for Anesthesia and Ventilation "Orpheus-M-01

Inhalational Anesthesia Machine for Anesthesia and Ventilation "Orpheus-M-01

$15,000-$48,000 USD
Industrial equipment
Factory direct from Russia
Krasnogvardeets OJSC 🇷🇺
Oxygen Generator for Medical Use, Model Oxymedic 50

Oxygen Generator for Medical Use, Model Oxymedic 50

$9,000-$30,000 USD
Industrial equipment
Factory direct from Russia
ONHS LLC 🇷🇺
Request via WhatsApp