Overall dimensions, mm
48×24×86
Basic error
Current and voltage: ±0.1, ±0.2 %
Operating temperature range
From -40 to +50 °C (relative humidity 95% at +35 °C)
LED indication
1 block of seven-segment indicators (4 indicators per block) for displaying voltage or current values
Height of indicator sign, mm
9,9
Input signal
60 mV, 75 mV, 100 mV, 150 mV, 200 mV, 250 mV, 500 mV, 1000 mV, 2000 mV; 1 V, 2 V, 5 V, 10 V, 2...10 V, 20 V, 50 V, 100 V, 150 V, 200 V, 250 V; 2 mA, 5 mA, 10 mA, 20 mA, 4...20 mA, 50 mA, 100 mA, 200 mA, 500 mA, 1000 mA, 2000 mA; 1 A, 2 A. Connection possib
Maximum reading range
-1999 to +9999
Galvanic isolation of output circuits, power supply circuits
Yes (no galvanic isolation on RS interface circuit)
RS485 communication interface
Quantity: 0 or 1; Modbus RTU protocol (Shch00Ps do not have galvanic isolation on RS interface circuit)
Power supply voltage
5V - (5 ± 0.25) VDC; 12V - (12 ± 0.6) VDC; 24V - (24 ± 1.2) VDC; external 5V stabilised power supply unit
Power consumption from the power supply circuit, not more
1,7 V-A
Reprogramming
Via "Configurator" programme (RS485 interface); via front panel push button
Degree of protection
IP50
Resistance to mechanical influences
Group 4 according to GOST 22261-94
Electromagnetic compatibility
GOST R 51317.6.5-2006 for class A equipment
Interference immunity
Functioning quality criterion A according to GOST R 51317.6.5-2006
Industrial noise level
GOST 30805.22-2013 for class A equipment
Performances
General industrial; for operation at NPPs (safety class 4 according to NP-001-2015)
Inspection interval
10 years
Warranty period of operation
36 mos.
Average service life, at least
20 years