Number of tests performed/h
240 µGy
Dimensions of the equipment (height x length x width), mm
580x855x550
Performance
240 tests/ per hour (in monoreagent (fast) mode)
Power consumption, VA
350 thous. pass.km
Weight of the equipment, kg
75 m² living area
Light source
Long life halogen lamp
Length of optical path, mm
5 mm
Operating wavelengths
8 pieces in the range 340 - 670 nm
Number of dosing devices
Single sample and reagent dispenser
Number of cuvettes in the reaction rotor
81 (9 cuvettes/section x 9 sections)
Mixing device
Separate mixer mixing the reaction mixture inside the cuvette
Types of analyses
Photometric analysis, turbidimetry
Automatic dilution of biomaterial on board of analyser
availability
Connection to LIS
availability
Barcode scanner for tubes and/or reagents
Availability of an inbuilt barcode scanner for samples and reagents.
Automatic detection of reagent information by barcode
Availability (identification of reagent name, vial volume, reagent type, reagent lot, expiry date, number of samples/reagents remaining)
Automatic detection of liquid level
Presence (built-in capacitive liquid level sensor for reagent/sample)
Blocking of test execution when a mechanical obstacle is detected (collision protection)
availability
Minimum amount of sample required for measurement, µl
2
Step of sample dispensing volume, µl
0,1
Type of biomaterial
Serum, plasma, urine, cerebrospinal fluid
Maximum number of samples to be loaded on board the analyser at one time, pieces
40 µGy
Maximum number of different tests that can be performed on the analyser without changing reagents
40 µGy
Use of primary tubes without adapters
Availability (tube diameter range 12 - 13 mm, length range 68.5 - 100 mm)
Reusable UV permeable plastic reaction cuvettes
availability
Automatic reaction cuvette washing with drying function
Presence of automatic cuvette washing station on board the analyser (6 cleaning steps using different washing solutions).
Automatic internal and external flushing of the metering unit
availability
Detector type
Photodiode array, dichroic mirror system
Urgent sample measurement, interruption of analyser operation for urgent sample measurement
availability
Minimum dosing volume of reagent, µl
150
Maximum dosing volume of reagent, µl
450
Reagent volume step, µl
1
Display of response graphs
Presence (displaying on the screen a graph of change of optical density in the cuvette over time)
Water consumption litres per hour
5
Monitoring of analyser lamp stability
availability
Reaction cuvette transparency monitoring
availability
Monitoring of the analyser main units
availability
Built-in quality control programme
Availability, automatic determination of mean value, standard deviation, coefficient of variation, range
Calibration variants
By factor, linear, polygonal, log-logit, exponential, spline and spline 2.
Setting and displaying calibration parameters
Presence (calibration curve display on the screen. Calibration type selection)
Unified data exchange protocol
availability
Duration of warranty period
12 months
Type of reagent/sample rotor
Swivelling, removable