Standby time after power on or power failure:not more than 2s
Power consumed from the "27 V" power supply network:No more than 10 W
Description
The TC-429R interface converter is designed for installation on air vehicles. The product provides conversion of information from ARINC 429 format to RS-422 format and vice versa.
Specifications
Continuous operation time
at least 15 h
Overall dimensions
151 × 66 × 31 mm
Standby time after power on or power failure
not more than 2s
Power consumed from the "27 V" power supply network
No more than 10 W
Increased temperatures
operating - plus 55 °C, short-term operating - plus 70 °C, limiting - plus 85 °C
Lowered temperatures
operating - minus 40 °C, limiting - minus 60 °C
Weight
0,280 ±0,028kg
Information exchange
The product provides conversion of information from ARINC 429 format to RS-422 format and its output via 5 parallel channels, as well as from RS-422 format to ARINC 429 format.
Питание в диапазоне температур
In the operating temperature range from minus 40 to plus 55 °C, the product functions normally when powered from the secondary power supply system of the aircraft at steady-state "27 V" network voltages from 18.0 to 31.5 V.
Related Products
Data Interface Converter RA-20 for CAN Networks
$90-$300 USD
Overall dimensions (DxWxH):
38
Weight:
0.08
ZAVOD PRIBOROV LLC 🇷🇺
Interface Conversion Unit 2.2
$90-$300 USD
Overall dimensions:
146×109×41 mm
Power supply voltage:
220
RANK 2 LLC 🇷🇺
RS-485 Interface Repeater-Splitter NLS-485C Ex
$90-$300 USD
Dimensions (H x W x D):
109x22.5x113
Power consumption:
0.5
NIL AP LLC 🇷🇺
Interface Conversion Module BPI RS-I
$90-$300 USD
Overall dimensions of the device:
110 x 32 x 38 mm
Power supply voltage:
9...27
ARGUS-SPEKTR LLC 🇷🇺
Interface Conversion Block for Distributed Control Point (RKP-PI-03)