Operating temperature range
From -40 to +50 °C (relative humidity 95% at +35 °C)
Overall dimensions, mm
96×24×86
LED indication
1 block of seven-segment indicators (4 indicators per block) for displaying voltage or current values
Height of indicator sign, mm
9,9
Input signal
60 mV, 75 mV, 100 mV, 150 mV, 200 mV, 250 mV, 500 mV, 1000 mV, 2000 mV; 1 V, 2 V, 5 V, 10 V, 2....10 V, 20 V, 50 V, 100 V, 150 V, 200 V, 250 V, 300 V, 500 V; 2 mA, 5 mA, 10 mA, 20 mA, 4...20 mA, 50 mA, 100 mA, 200 mA, 500 mA, 1000 mA, 2000 mA; 1 A, 2 A. Po
Maximum reading range
From -9999 to +9999
Basic error
Current and voltage: ±0.1, ±0.2 %; analogue output: ±0.5 %
Galvanic isolation of output circuits, power supply circuits
Got it
RS485 communication interface
Quantity: 0 or 1; Modbus RTU protocol
Analog outputs
Quantity: 0, 1, 2; Ranges (reprogrammable): 0...5 mA, 4...20 mA, 0...20 mA, 0...2.5...5 mA, 4...12...20 mA, 0...10...20 mA
Discrete outputs
Quantity: 0; 1; 2; DC voltage 300 V, 100 mA or AC voltage 200 V, 100 mA
Power supply voltage
5V - (5 ± 0.25) Vdc; 12V - (12 ± 0.6) Vdc; 24V - (24 ± 1.2) Vdc
Power consumption from the power supply circuit, not more
2,7 V-A
Reprogramming
Via "Configurator" program (RS485 interface); via front panel button
Degree of protection
IP50
Resistance to mechanical influences
Group 4 according to GOST 22261-94
Electromagnetic compatibility
GOST R 51317.6.5-2006 for class A equipment
Interference immunity
Functioning quality criterion A according to GOST R 51317.6.5-2006
Industrial noise level
GOST 30805.22-2013 for class A equipment
Performances
General industrial; for operation at NPPs (safety class 4 according to NP-001-2015)
Inspection interval
10 years
Warranty period of operation
36 mos.
Average service life, at least
20 years