Products — Smoke Detectors
Optical-Electronic Linear Smoke Detector IP212-75Ex-Yastreb
US$90-300
Maximum possible room area protected by one detector:
900
Range of possible distances between the transceiver and the reflector-reflector:
8...100
IVS LLC 🇷🇺
Optical-Electronic Linear Addressable Smoke Detector IP212-C6500-XX
US$90-300
Maximum possible room area protected by one detector:
1080
Range of possible distances between the transceiver and the reflector-reflector:
8...120
IVS LLC 🇷🇺
Optical-Electronic Linear Smoke Detector IPD-75CMD
US$90-300
Range of possible distances between the transceiver and the reflector-reflector:
8...120
Maximum possible width of the area to be protected by one detector:
9
IVS LLC 🇷🇺
Optical-Electronic Smoke Detector IП212-44Ex DIP-44Ex
US$9-36
Sensitivity of detectors corresponds to smoke environment with optical density, dB/m:
0.05...2
Inertia of detectors triggering from the in-built test device, not more:
5
IVS LLC 🇷🇺
Optical Smoke Detector IP212-44 with MS-01 Model DIP-44 with MS-01
US$3-18
Sensitivity of detectors corresponds to smoke environment with optical density, dB/m:
0.05...0.2
Power supply voltage (from DC source):
9...15
IVS LLC 🇷🇺
Linear Optical-Electronic Smoke Detector IP212-75Ex
US$90-300
Range of possible distances between the transceiver and the reflector-reflector:
8...100
Maximum possible width of the space to be protected by one detector:
9
IVS LLC 🇷🇺
Optical-Electronic Linear Smoke Detector IPD-52 Model IP212-52
US$90-300
Range of possible distances between receiver and transmitter:
8...100
Maximum possible width of the space to be protected by one detector:
9
IVS LLC 🇷🇺
Optical-Electronic Smoke Detector IP212-54T “DIP-54T”
US$3-18
Detector supply voltage:
8...36
Sensitivity of the detector corresponds to the smoke environment with optical density, dB/m:
0.05...0.2
IVS LLC 🇷🇺
Optical Smoke Detector IP212-43 Antishock Model DIP-43
US$3-12
Sensitivity of the detector corresponds to the smoke environment with optical density, dB/m:
0.05...0.2
Inertia of detector operation from the built-in test device, not more than:
5
IVS LLC 🇷🇺
Optical-Electronic Linear Smoke Detector IP212-52C
US$90-300
Range of possible distances between receiver and transmitter:
8...140
Maximum possible width of the space to be protected by one detector:
9
IVS LLC 🇷🇺
Optical-Electronic Smoke Detector IP212-44Ex V1 for Hazardous Areas
US$9-30
Sensitivity of detectors corresponds to smoke environment with optical density, dB/m:
0.05...0.2
Inertia of detectors operation from the inbuilt test device, not more:
5
IVS LLC 🇷🇺
Optical Electronic Smoke Detector DIP-43MK Model IP212-43MK
US$3-12
Power supply voltage:
4.5...6.5
Sensitivity of the detector corresponds to the smoke environment with optical density, dB/m:
0.05...0.2
IVS LLC 🇷🇺
Post your Buy Requirement
Get Quotes from Verified Suppliers
Save Your Time
Optical-Electronic Smoke Detector IP212-44 "DIP-44
US$3-18
Degree of protection of the shell against penetration of solid bodies in accordance with GOST 14254:
40
Degree of rigidity in terms of resistance to electromagnetic interference:
4
IVS LLC 🇷🇺
Linear Optical-Electronic Smoke Detector IP212-S300 IPDL
US$15-60
Range of possible distances between the transceiver and the reflector-reflector:
8...120
Maximum possible width of the area to be protected by one detector:
9
IVS LLC 🇷🇺