Тауарлар — Кабельдер және сымдар

OLFLEX FLAT RU кабелі

OLFLEX FLAT RU кабелі

₸427.50-1,710
LAPP RUSSIA LLC 🇷🇺
Кабельдер күштік (А)ВВГ

Кабельдер күштік (А)ВВГ

₸570-8,550
TATKABEL LLC 🇷🇺
Күштік кабель КГВВЭнг(А)-LS-2

Күштік кабель КГВВЭнг(А)-LS-2

₸142.50-855
Alyur Cable Plant LLC 🇷🇺
Кабель КПГТнг(А)-HF

Кабель КПГТнг(А)-HF

₸427.50-2,850
SARANSKKABEL LLC 🇷🇺
KIS-RP-KShpng(A)-FRHF 1х2х1,38

KIS-RP-KShpng(A)-FRHF 1х2х1,38

₸427.50-1,710
TPD PARITET LLC 🇷🇺
Kabel PvPng(A)–HF

Kabel PvPng(A)–HF

₸427.50-1,710
EM-KABEL LLC 🇷🇺
Күштік кабель ВБШвнг(А)-FRLS

Күштік кабель ВБШвнг(А)-FRLS

₸570-2,850
KAVKAZKABEL LLC 🇷🇺
Кабель ДПС-нг(А)-FRHF

Кабель ДПС-нг(А)-FRHF

₸4,275-17,100
INKAB LLC 🇷🇺
Күштік кабель ВБШв

Күштік кабель ВБШв

₸285-1,710
EKZ OJSC 🇷🇺
Кабельдер КуВВнг(А)-LS

Кабельдер КуВВнг(А)-LS

₸285-2,850
KIRSKABEL OJSC 🇷🇺
51H1A4 қосқыш кабелі

51H1A4 қосқыш кабелі

₸1,425-8,550
GTLAB LLC 🇷🇺
EPREM АРэБВ күштік кабельдер

EPREM АРэБВ күштік кабельдер

₸4,275-17,100
EM-KABEL LLC 🇷🇺
Kabel KIS-RP-Kng(A)-FRHF 1х2х0,50

Kabel KIS-RP-Kng(A)-FRHF 1х2х0,50

₸427.50-1,710
TPD PARITET LLC 🇷🇺
Кабель КГТП-ХЛ 3*2,5+1*1,5-0.38

Кабель КГТП-ХЛ 3*2,5+1*1,5-0.38

₸199.50-712.50
Irkutskkabel OJSC 🇷🇺
Кабель АВКШв-ХЛ

Кабель АВКШв-ХЛ

₸427.50-2,850
EM-KABEL LLC 🇷🇺
Күш кабелі (А)РвКаПнг(А)2г-FRHF

Күш кабелі (А)РвКаПнг(А)2г-FRHF

₸4,275-28,500
TATKABEL LLC 🇷🇺
Кабель күшті икемді КГ

Кабель күшті икемді КГ

₸142.50-1,710
EKZ OJSC 🇷🇺

FAQ

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.