Measured vibration velocity range, RMS
0 ... 10 mm/s
Operating frequency range of measured vibration velocity (AFC non-uniformity - 1 dB)
3 … 1,000 Hz
output
voltage 0 ... 10 V
Input/output connectors
screw terminal blocks
Measurement error in the operating temperature range
±2 %
Types of connected vibration transducers
IEPE, voltage output and negative power
Sensor supply voltage
IEPE + 24 ± 2 V
IEPE sensor supply current (±10 %)
5.7 mA
Dry contacts
for vibration speed control LIM1, LIM2
Parameters of built-in comparators
thresholds for activation of vibration speed 0.1 ... 100 mm/s
Conditions of signalling (closed or open) of "LIM1", "LIM2" relay contacts
Continuous exceeding of the informative signal of the set threshold value for 0-100 s
Mode of operation of relay contacts
blocking/self-recovery
Self-recovery condition
6% reduction in vibration from activation threshold
Delay of vibration control after establishing operation mode/self-recovery
0 or 20
Dry contact parameters
switching current < 2 A
Information displayed on the built-in display
vibration velocity, sensor conversion coefficient, set threshold values, error codes for cable break and sensor failure, threshold exceed time setting, relay contact status
Consumption current
< 200 mA
feature
parameter measurement via spectral analysis (FFT)
Step of setting the time of exceeding the vibration velocity threshold values
1
Supply voltage (±10 %)
18...36 V
Operating temperature range
-40...70 °C