Full power
50000...240000
type
double conversion UPS
Parallel operation function
yes
Rated output voltage
415 V
Nominal input frequency
60
Rated output frequency
60
Maximum permissible nominal voltage of rechargeable batteries
600 V
Communication interface
RS232, RS485, SNMP, CAN
Minimum battery life at design load
5
Possibility to connect external batteries
yes
Uninterruptible power supply form factor
standalone
Type of batteries used
lead-acid, nickel-cadmium, lithium-ion
Display availability
touchscreen LCD
Presence of terminal output
yes
Earthquake-proof design
optional
Rated power
50000...216000 W
Active power
50000...216000 W
Uninterruptible power supply efficiency
97 %
Minimum permissible nominal voltage of batteries
360 V
Reducing input voltage without switching to battery use
305 V
Increasing the input voltage without switching to battery use
485 V
Permissible operating time at overload 110%
60
Permissible operating time at overload 125%
10
Permissible operating time at overload 150 %
1
Current input nonlinear distortion factor (THDi)
3 %
Output voltage nonlinear distortion coefficient (THDv)
1 %
Output power factor
0.9...1
Maximum ambient temperature
40 °C
Maximum ambient relative humidity
95 %
Estimated load power relative to nominal load power in kW for selecting the autonomous operation time
100 %
Number of battery rooms
1...10 pcs
Height of one battery cabinet
1000...2500 mm
Width of one battery cabinet
500...1500 mm
Depth of one battery cabinet
500...1500 mm
Lower limit of input voltage range (phase-to-neutral) without switching to battery operation mode
138 V
Upper limit of input voltage range (phase-to-neutral) without switching to battery operation mode
485 V
Charger power at rated load power relative to the rating of the uninterruptible power supply, not less than
16 %
Availability of a network card as part of the uninterruptible power supply unit
Yes
Space for uninterruptible power supply maintenance
front 800mm, back 0 to 500mm
Integrated N+1 redundancy (module level) for modular uninterruptible power supplies
yes
Model architecture of uninterruptible power supply power section
yes
Availability of advanced monitoring when using modular batteries
optional
Supports plug-n-play technology when using modular batteries
yes
Uninterruptible power supply phase (input:output)
3:3
Input connection
depending on configuration
Output connection
depending on configuration
Nominal input voltage
415 V
Battery arrangement
inside/outside UPS
Type of battery cabinet design
built-in/free-standing
Modular uninterruptible power supply battery architecture
yes
Redundancy in parallel operation
yes
Availability of high energy efficiency mode
yes
Charging batteries in high energy efficiency mode
yes
Interference correction in high power efficiency mode
yes
Zero (0ms) switching time from high energy efficiency mode
yes
Uninterruptible power supply load self-test mode with no load connected
yes
Power supply voltage
415 V