Presence of biofeedback (biofeedback).
可用
Presence of motivating 3D game environments
Наличие
Video recording of evaluation and training procedures
有
Appointment of the device
用于:1) 分析生物力学/神经肌肉步态功能,使用专业设备;2) 基于患者互动的各解剖区域的神经肌肉康复治疗
Method of motion registration
生物识别传感器
Automatic calculation of walking time parameters, walking phases, spatial parameters of walking, kinematic parameters of walking
有
Ability to pre-assess walking function prior to training.
有
Possibility to select any recorded walking parameter (temporal, spatial, EMG or kinematic) as B
有
Ability to change the complexity of training tasks during training.
有
Possibility of carrying out training in automatic mode (automatic selection of training difficulty)
有
Possibility to control other (not selected as parameters of the EBS) parameters of the patient's walking during training
有
Automatic generation of evaluation and training protocol
有
Saving completed assessments and drills, as well as their protocols in the database
可用
Possibility to change the list of calculated parameters for biomechanical/neuromuscular function analysis
有
Ability to view previously completed walking function assessments/trainings and their protocols.
有
Ability to create custom templates for walking function assessment and training protocols
有
Built-in protocol template editor
有
Ability to edit evaluation and training protocols
可用
Ability to include graphs, figures and tables in the protocols
可用
Availability of a consolidated protocol to track the dynamics of rehabilitation
可用性
Base of medical norms on basic parameters of walking (phases of walking, temporal parameters, spatial parameters, kinematics)
有
Monitoring the condition of equipment during evaluations and drills
可用
Types of registration channels
加速度计,陀螺仪,肌电图
Sensor weight
不超过40(± 4)克
Dimensions of the sensor
不超过 60×40×17 (± 2) 毫米
Wireless communication with PC
有
communication range
视距不小于 10 米
Maximum number of sensors simultaneously linked to one PC
不少于12个
Sensor synchronization accuracy
差异不超过 0.005 秒
Quantization frequency
至少200赫兹
Input range of measured accelerations in each of the three axes
不小于 ±16g
Permissible error of acceleration measurement in each of the three axes
不超过±(0.04 g + 5%测量值)
Input range of angular velocities in each of the three axes
不小于 ± 2000 度/秒
Permissible error of angular velocity measurement in each of the three axes
不超过±(0.5度/秒 + 2%测量值)
Total number of differential channels per 1 sensor
至少2
In-phase noise reduction (CMRR)
至少100分贝
Lower bandwidth limit at level (-3 ± 0.5) dB in EMG measurement mode
不超过5 Hz
Upper limit of the bandwidth at the level of (-3 ± 0.5) dB in the EMG measurement mode
不小于 500 赫兹
Natural noise level in EMG measurement mode
不超过 2 微伏 RMS
Input differential resistance
不小于 100 兆欧
EMG signal input range
不窄于 0.07 微伏 – 20 毫伏
EMG signal measurement error in the input range from 0.07 µV to 20 mV and at the bandwidth from 5 to 500 Hz
不超过±(7微伏 + 5%测量值)
Suppression of mains interference by a switchable tap selector filter
至少40分贝
Function for determining the sub-electrode impedance
可用