
Static Milur 307 TSCYA.411152.007-01.???
Manufacturer:
Price:
Request Quote
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Description
"Static, unidirectional three-phase multitariff universal transformer or direct inclusion meter, with built-in microcontroller and with a variety of interfaces counting mechanism to exchange information with external devices.
The meter of direct inclusion is designed for accounting of active and reactive electric energy in four-wire AC networks with nominal voltage of 3x230/400V. The basic (maximum) current is 5(100) A. The meter, switched on through a current transformer, is designed for accounting of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x230/400V. Rated (maximum) current is 5(10)A. The meter, included through current and voltage transformers, is designed for metering of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x57.7/100V. Rated (maximum) current is 5(10)A.
The meter is produced in the case:
- 9mTN35 - mounting on the rail TN35 according to GOST R IEC 60715 (DIN-rail), width 157 mm (9 modules of 17.5 mm), IP51.
For each modification of the counters there is a release of versions containing the following additional devices or functions:
- additional communication interface (RS-485, RF868, PLC, PLC.G3/RF868, ZigBee);
- programmable load switching on/off control output.
Display of consumed electrical energy is carried out on the liquid crystal display (hereinafter - LCD) of the meter.
The meter displays readings directly in kilowatt-hours (kWh) when measuring active energy and in kilovar-hours (kvar-h) when measuring reactive energy.
reactive energy measurement. The amount of stored electricity is displayed as eight digits, with the three or two lower digits separated by a comma, representing thousandths or hundredths of kWh (kvarh) for transformer or direct current meters, respectively.
The LCD displays:
- values of accumulated cumulative total of active and reactive energy
for each (up to 8) tariffs with indication of the tariff number;
- total (for all tariffs) value of accumulated cumulative total active and reactive energy
consumed active and reactive energy;
- current active, reactive and total power for each phase and
total value (reference value);
- voltage and current for each phase (reference value);
- mains frequency (reference value);
- power factor per phase and total value (reference value); power factor per phase and total value (reference value); power factor per phase and total value (reference value).
value);
- phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value).
value);
- phase shift between phase voltages (reference value);
- absence of phase voltage (flashing symbol for phase A, B or C);
- open key symbol (if the terminal block cover is not fitted);
- backup battery voltage (reference value);
- current time and date;
- network address of the meter;
- software version;
- software numeric identifier;
- date and time of the last access to the optional interface.
Meters provide registration and storage in non-volatile memory
the following information:
- values of metered active and reactive energy accumulated cumulatively from the moment of manufacture
total and for each (up to 8) tariffs;
- values of metered active and reactive energy by tariffs for each month of the year;
- values of metered active and reactive energy per day according to tariffs for the last 123 days;
- values of metered active and reactive energy, as well as maximum active and reactive power
half-hourly power slices for the last 123 days;
- instantaneous values of active, reactive and full load power
phase by phase and total value (reference value);
- instantaneous values of effective voltage and current for each phase
(reference value);
- clock calibration factor;
- voltage of the built-in battery of the backup power supply (reference value); voltage of the built-in battery of the backup power supply (reference value)
reference value);
- annual tariff schedule and exceptional (public) days;
- modification and serial (factory) number of the meter;
- serial number of the printing unit;
- software version number (identification number);
- digital identifier (checksum) of the software;
- time and date of opening of terminal covers;
- power on/off time;
- time and date of the start and end of magnetic field exposure."
The meter of direct inclusion is designed for accounting of active and reactive electric energy in four-wire AC networks with nominal voltage of 3x230/400V. The basic (maximum) current is 5(100) A. The meter, switched on through a current transformer, is designed for accounting of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x230/400V. Rated (maximum) current is 5(10)A. The meter, included through current and voltage transformers, is designed for metering of active and reactive electrical energy in four-wire AC networks with nominal voltage of 3x57.7/100V. Rated (maximum) current is 5(10)A.
The meter is produced in the case:
- 9mTN35 - mounting on the rail TN35 according to GOST R IEC 60715 (DIN-rail), width 157 mm (9 modules of 17.5 mm), IP51.
For each modification of the counters there is a release of versions containing the following additional devices or functions:
- additional communication interface (RS-485, RF868, PLC, PLC.G3/RF868, ZigBee);
- programmable load switching on/off control output.
Display of consumed electrical energy is carried out on the liquid crystal display (hereinafter - LCD) of the meter.
The meter displays readings directly in kilowatt-hours (kWh) when measuring active energy and in kilovar-hours (kvar-h) when measuring reactive energy.
reactive energy measurement. The amount of stored electricity is displayed as eight digits, with the three or two lower digits separated by a comma, representing thousandths or hundredths of kWh (kvarh) for transformer or direct current meters, respectively.
The LCD displays:
- values of accumulated cumulative total of active and reactive energy
for each (up to 8) tariffs with indication of the tariff number;
- total (for all tariffs) value of accumulated cumulative total active and reactive energy
consumed active and reactive energy;
- current active, reactive and total power for each phase and
total value (reference value);
- voltage and current for each phase (reference value);
- mains frequency (reference value);
- power factor per phase and total value (reference value); power factor per phase and total value (reference value); power factor per phase and total value (reference value).
value);
- phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value); phase shift between current and voltage in each phase (reference value).
value);
- phase shift between phase voltages (reference value);
- absence of phase voltage (flashing symbol for phase A, B or C);
- open key symbol (if the terminal block cover is not fitted);
- backup battery voltage (reference value);
- current time and date;
- network address of the meter;
- software version;
- software numeric identifier;
- date and time of the last access to the optional interface.
Meters provide registration and storage in non-volatile memory
the following information:
- values of metered active and reactive energy accumulated cumulatively from the moment of manufacture
total and for each (up to 8) tariffs;
- values of metered active and reactive energy by tariffs for each month of the year;
- values of metered active and reactive energy per day according to tariffs for the last 123 days;
- values of metered active and reactive energy, as well as maximum active and reactive power
half-hourly power slices for the last 123 days;
- instantaneous values of active, reactive and full load power
phase by phase and total value (reference value);
- instantaneous values of effective voltage and current for each phase
(reference value);
- clock calibration factor;
- voltage of the built-in battery of the backup power supply (reference value); voltage of the built-in battery of the backup power supply (reference value)
reference value);
- annual tariff schedule and exceptional (public) days;
- modification and serial (factory) number of the meter;
- serial number of the printing unit;
- software version number (identification number);
- digital identifier (checksum) of the software;
- time and date of opening of terminal covers;
- power on/off time;
- time and date of the start and end of magnetic field exposure."
Specifications
Nominal voltage
3×57,7/100 or 3×230/400 V
Set operating voltage range
0.9 to 1.1 Unom V V
Extended operating voltage range
0,8 to 1,15 Unom V V
Base (maximum) current (for directly connected meter)
5 (100) A
Rated (maximum) current (for a meter switched through a current or voltage transformer)
5 (10) A
Rated mains frequency
SBVVBG
Accuracy class
0,2S/0,5 according to GOST 31819.22/TU or 0,5S/1 according to GOST 31819.22/GOST 31819.23 or 1/2 GOST 31819.21/GOST 31819.23
Number of tariffs, not less
8
Number of tariff zones, not less than
16
Type of inclusion
Through current and voltage transformers or through current transformer or direct connection
Direction of metered energy
Unidirectional
Housing type
9mTN35
Protection class
IP51
Temperature
minus 40 to plus 70 °C
Average MTBF, not less than
220000
Average service life, at least
30 a
Warranty period of operation
42
Operating conditions
Indoors
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Electric energy meters three-phase multifunctional "MIRTEK-32-RU". Case SP31
View Details
MIR S-05 type electricity meter
View Details
Electricity meters three-phase multifunctional MIRTEK-32-RU-W37-1
View Details
Static three-phase multifunctional static electricity meters ATOM 3 R34
View Details
M2M-1 single-phase multifunctional energy meter
View Details
Multifunctional electric energy meter SET-4TM.02MT
View Details
Electricity meter static three-phase FOBOS 3 230V 5(100)A IQORT(16)LM-D 4G(LTE) SMA
View Details
Milur 307S.52-GRR-2-D static energy meter
View Details
Electric energy meters EMIS-ELEKTRA 971 version "C"
View Details
Electricity meter KVANT ST2000-12-W-230*5(10)-0,5S/1-RUxxI2O2xxxxDM
View Details
Electric energy meters three-phase multifunctional CE308 S34
View Details
DC power metering device SKVT-F610
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions