Milur 107 static electricity meter TSKYA.411152.006-01.XXX
Manufacturer:
Price:
Request Quote
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Description
One-phase, direct inclusion, multi-tariff static electricity meter Milur 107 with built-in microcontroller is designed for measuring and metering of electric active and reactive energy in two-wire AC networks with voltage 230 V and frequency 50 Hz. The basic (maximum) load current is 5(80) A. The meter can be operated both autonomously and as part of automated systems of commercial electricity metering ASKUE with a pre-set programme and the ability to set (correct) the appropriate schedule.
The meter is available in versions containing the following additional devices or functions:
- additional communication interface (RS-485, PLC, RF868, ZigBee);
- hardware load switching on/off;
- additional current sensor in the "zero" wire.
The meter is available in the case:
- 7mTN35 - mounting on the rail TN35 according to GOST R IEC 60715 (DIN-rail), width 123 mm (7 modules of 17.5 mm), IP51.
Display of consumed electrical energy is carried out on the liquid crystal display (hereinafter - LCD) of the meter.
The counting mechanism indicates readings directly in kilowatt-hours (kW?h) when measuring active energy and in kilowar-hours (kvar?h) when measuring reactive energy. The value of the stored electricity is displayed as eight-digit numbers, where the two lower digits separated by a comma represent tenths and hundredths of kWh (kvar-h).
The LCD, in the appropriate operating modes, displays the following information:
- active and reactive energy consumed in total and according to the established tariffs;
- active tariff number;
- date and time;
- network address of the meter;
- software version number (identification number);
- digital identifier (checksum) of the software.
Additional parameters, for reference:
- current active power;
- current reactive power;
- current total power;
- voltage and current;
- power factor of energy;
- frequency;
- date (date and month) and time (hours, minutes) of the last access to the meter via the interface;
- the "grid" symbol, which detects an attempt to steal electricity;
- voltage of the built-in battery.
The meters provide registration and storage in non-volatile memory (depending on the modification):
- values of metered active and reactive energy in cumulative total from the moment of manufacture for all tariffs;
- values of metered active and reactive energy as of the beginning of each month for all tariffs for twelve months;
- values of metered active and reactive energy at the beginning of each day for all tariffs for the last 123 days;
- values of metered active and reactive energy, as well as maximum active and reactive power of half-hourly power slices for the last 123 days;
- tariff schedule;
- serial (factory) number of the meter;
- software version number (identification number);
- digital identifier (checksum) of the software;
- time and date of opening the terminal and interface covers.
During operation, the meters provide:
- maintaining an event log with the date and time of power on/off, opening of the terminal block cover and interface cover, clock correction and tariff schedule;
- maintenance of a load power profile array with programmable integration time;
- control of the load by generating a control signal on a configurable test output or by means of an inbuilt relay.
All measured parameter values are stored in the non-volatile memory of the meters.
The meter is available in versions containing the following additional devices or functions:
- additional communication interface (RS-485, PLC, RF868, ZigBee);
- hardware load switching on/off;
- additional current sensor in the "zero" wire.
The meter is available in the case:
- 7mTN35 - mounting on the rail TN35 according to GOST R IEC 60715 (DIN-rail), width 123 mm (7 modules of 17.5 mm), IP51.
Display of consumed electrical energy is carried out on the liquid crystal display (hereinafter - LCD) of the meter.
The counting mechanism indicates readings directly in kilowatt-hours (kW?h) when measuring active energy and in kilowar-hours (kvar?h) when measuring reactive energy. The value of the stored electricity is displayed as eight-digit numbers, where the two lower digits separated by a comma represent tenths and hundredths of kWh (kvar-h).
The LCD, in the appropriate operating modes, displays the following information:
- active and reactive energy consumed in total and according to the established tariffs;
- active tariff number;
- date and time;
- network address of the meter;
- software version number (identification number);
- digital identifier (checksum) of the software.
Additional parameters, for reference:
- current active power;
- current reactive power;
- current total power;
- voltage and current;
- power factor of energy;
- frequency;
- date (date and month) and time (hours, minutes) of the last access to the meter via the interface;
- the "grid" symbol, which detects an attempt to steal electricity;
- voltage of the built-in battery.
The meters provide registration and storage in non-volatile memory (depending on the modification):
- values of metered active and reactive energy in cumulative total from the moment of manufacture for all tariffs;
- values of metered active and reactive energy as of the beginning of each month for all tariffs for twelve months;
- values of metered active and reactive energy at the beginning of each day for all tariffs for the last 123 days;
- values of metered active and reactive energy, as well as maximum active and reactive power of half-hourly power slices for the last 123 days;
- tariff schedule;
- serial (factory) number of the meter;
- software version number (identification number);
- digital identifier (checksum) of the software;
- time and date of opening the terminal and interface covers.
During operation, the meters provide:
- maintaining an event log with the date and time of power on/off, opening of the terminal block cover and interface cover, clock correction and tariff schedule;
- maintenance of a load power profile array with programmable integration time;
- control of the load by generating a control signal on a configurable test output or by means of an inbuilt relay.
All measured parameter values are stored in the non-volatile memory of the meters.
Specifications
Nominal voltage
230 V
Set operating voltage range
207...253 V
Extended operating voltage range
184...265 V
Base (maximum) current
5 (80) A
Rated mains frequency
SBVVBG
Number of tariffs, not less
4
Number of tariff zones
8
Type of inclusion
Direct inclusion
Housing type
7mTN35
Protection class
IP51
Temperature
minus 40 to plus 70 °C
Average MTBF, not less than
220000
Average service life, at least
30 a
Warranty period of operation
42
Operating conditions
Indoors
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Electricity meter single-phase intellectual NARTIS-I100-W112-2
View Details
Three-phase electric energy meters NEVA SP3
View Details
Electricity meter three-phase smart NARTIS-I300-W133-2
View Details
Three-phase static electricity meter FOBOS 3T 230V 5(10)A IQORLM-A
View Details
Electric energy meter KVANT ST1000-9-C-5(80)N-1/1-Bxxxxxxx
View Details
Electricity meter static three-phase FOBOS 3 230V 5(100)A IQORG(2)G(6)L(1)-D
View Details
Three-phase electricity meters RIM 489.48
View Details
Static three-phase electricity meter FOBOS 3 230V 5(100)A IQOG(4)LS-C
View Details
Electric energy meters three-phase multifunctional "KASKAD-32-MT". Case W32.
View Details
Electric energy meter type MIR S-04
View Details
Milur 107S.22-KRZ-1L-DT static energy meter
View Details
Electric energy meters three-phase multifunctional "MIRTEK-32-RU". Case W32.
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions