Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, grade GERDA-KPsKng(A)-FRHF

Manufacturer:
Price: Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Key Highlights

  • Made in Russia - engineered for durability
  • Suitable for challenging environments
  • Lower cost of ownership than European alternatives
  • Bulk orders available with volume discounts
  • Documentation and customs clearance assistance provided

Available Models

Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPsBng(A)-HF Installation cable, pair twisted, flame retardant, with copper or copper tinned conductors, mark GERDA-KVKVng(A)-FRLS Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, markGERDA-KVBng(A)-FRLSLTx Installation cable, pair twisted, flame retardant, with copper or copper tinned conductors, mark GERDA-KVng(A)-FRLSLTx Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPKng(A)-FRHF
Installation cable, pair twisted, fireproof, with copper or copper tinned conductors, mark GERDA-KVBng(A)-FRLS. Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, grade GERDA-KPSBng(A)-FRLS Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPsKng(A)-HF Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KV Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPsng(A)-LS Installation cable, pair twisted, flame retardant, with copper or copper tinned conductors, mark GERDA-KVKKng(A)-FRLSLTx Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVng(A)-LS Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVBng(A). Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPsng(A)-FRHF Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVB Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPsng(A)-HF Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVBng(A)-LS Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KVKVng(A)-LSLTx Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPKng(A)-HF Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPKng(A)-FRHF Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KVKng(A)-FRLS Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KVKKng(A)-LSLTx Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPKng(A)-HF Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVKng(A)-LS. Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPBng(A)-HF Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KVBng(A)-LSLTx Installation cable, pair twisted, with copper or tinned copper conductors, grade GERDA-KPsKng(A)-LS Installation cable, pair twisted with copper or tinned copper conductors, mark GERDA-KVKVng(A). Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, grade GERDA-KPsKng(A)-FRLS Installation cable, pair twisted, with copper or tinned copper conductors, mark GERDA-KPsBng(A)-LS Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPsBng(A)-FRHF Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPBng(A)-FRHF Installation cable, pair twisted, flame retardant, with copper or tinned copper conductors, mark GERDA-KPSng(A)-FRLS

Description

Mounting cables, twisted pair with tinned copper cores, shielded, with the number of pairs up to 44 inclusive, nominal cross-section of cores from 0,35 to 2,5 mm², operating at a voltage of up to 500 V AC 50 or 60 Hz or up to 750 V DC, including places exposed to stray currents.

Specifications

Fire hazard class P1b.1.1.1.2.1.
Sheath material Polymer compositions; halogen-free
Insulation material crosslinked polyolefin
Design feature wire-armored
Index "FR" fireproof
Minimum cable installation temperature minus 15 °C
Operating temperature -50 to +70 °C
Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, Russia CIF Available to major ports worldwide EXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C) Wire Transfer (T/T) Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.