Description
Fire-resistant cable, not spreading combustion, with low smoke and gas emission, designed for transmission and distribution of electrical energy and electrical signals in stationary electrical installations at nominal AC voltage of 380, 500, 660 and 1000 V with frequency up to 100 Hz or at DC voltage of 500, 750, 1000 and 1500 V respectively.
Specifications
The cables are designed for
Cable lines for power supply of safety systems equipment, wiring of fire safety systems circuits (fire alarm circuits, power supply of fire extinguishing pumps, lighting of emergency exits and escape routes, smoke extraction and supply ventilation systems)
Permissible heating temperatures of cable cores
long-term permissible - not more than 70°?; in overload mode - not more than 90°?; short-circuit limit - 160°?; under the condition of short-circuit non-fire - not more than 350°?. °C
Installation conditions
Cables may be laid without limitation of level difference along the route of laying, including vertical sections. Permissible tension forces of cables during laying shall not exceed 50 N/mm2. The permissible bending radius of multicore cables during laying
Conditions of safe operation
Cables are designed for operation at ambient temperature from -50°? to +50°? and relative humidity up to 98% at temperature up to 35°?.
Cable storage period in closed rooms
Not more than 10 yrs.
Period of cable storage under a shelter
no more than 5 years
Cable storage period in open areas
no more than 2 years
Conditions of transportation and storage of cables in terms of exposure to climatic factors of external environment
must comply with group OZh2 according to GOST 15150-69
Transportation and storage of cables shall comply with the following requirements
GOST 18690-2012 and GOST 31996-2012
Areas of application
For group laying of cable lines in the air if there is no danger of mechanical damage during operation; in dry or damp rooms (tunnels), channels, cable half floors; in mines, collectors, industrial premises, partially behind
Accommodation category
1-5 (GOST 15150-69)
Climatic version
UHL and T
Nominal cross-section
1.5 to 400 mm2
Number of conductive cores
1 to 5 pc
Structural design
Power cables with copper conductive cores, with thermal barrier made of mica-containing tapes, with insulation and sheathing made of polyvinylchloride plasticate of reduced fire hazard, single-wire or multi-wire, round or sector shape.
Purpose
Intended for transmission and distribution of electric energy and electric signals in stationary electrical installations at rated alternating voltage of 380, 500, 660 and 1000 V, frequency up to 100 Hz or at direct voltage of 500, 750,1
Main features
Cables flame retardant, non-combustible, low smoke and gas emissions
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Flame retardant, non-combustible, low smoke and gas emission cable, KMTBVng(A)-FRLS grades
View Details
Flexible power cables for voltage up to 220 V KOG1
View Details
Power cable VBSHV-XL for rated voltage 0,66 and 1 kV
View Details
Power cables with copper conductors with plastic insulation for rated voltage of 1 kV brand PvBShp(d)
View Details
Power cables with plastic insulation at voltage 0,66 kV of VKaShvng(A) type.
View Details
Power cables, not spreading combustion, with insulation and sheathing made of polymer composites, halogen-free type BCPN
View Details
Power cables with plastic insulation, not spreading combustion, with low smoke and gas emission for voltage 0,66 and 1 kV
View Details
Power cables of TOFLEX trade mark, rated voltage 1 kV, alternating current frequency 50 Hz, TOFLEX RERng(A)-FRHF
View Details
Polymer-insulated, flame-retardant, cold-resistant, up to 1 kV, KRIOSIL VAGSHVng( grade).
View Details
Flexible fire-resistant cable, grade: KGVEVng(A)-FRLSLTx
View Details
Power cable with copper conductors insulated with cross-linked polyethylene for voltage 1 kV of PvVVGng(A)-LS grade
View Details
Power cables, fire-resistant, not spreading combustion, with copper conductors with plastic insulation for rated voltage e
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions