Automatic road weather station INEI

Manufacturer:
Price: Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Key Highlights

  • Made in Russia - engineered for durability
  • Suitable for challenging environments
  • Lower cost of ownership than European alternatives
  • Bulk orders available with volume discounts
  • Documentation and customs clearance assistance provided

Description

Automatic road meteorological station INEY is designed for automatic measurements of meteorological parameters: air temperature, roadbed temperature, ground temperature, relative humidity, speed and direction of air flow, atmospheric pressure, thickness of water layer, snow, ice on the road surface, meteorological optical range, amount and intensity of precipitation, as well as for local collection, processing and transmission of monitoring parameters to external users.
Automatic road meteorological station INEI is able to analyse the condition of the road surface to determine the amount and concentration of anti-icing agent, the amount of snow, water or moisture on the surface and the freezing temperature, as well as to warn about the presence of ice, snow and precipitation.

Specifications

Atmospheric pressure measuring range 26-126
Absolute error tolerance limits of atmospheric pressure measurements ± 0.03
Measuring range of air temperature -60 to +85 °C
Limits of permissible absolute error of air temperature measurements in the range from -60 ºC to +20 ºC on: ±(0.17-0.0028?t); in the range from +20 ºC to +85 ºC: ±(0.07+0.0025?t), where t is the measured temperature value without taking into account the sign. °C
Ground Temperature Measurement Range -50 to +60 °C
Limits of permissible absolute error of ground temperature measurements ±0,2 °C
Measuring range of road surface temperature -50 to +80 °C
Limits of permissible absolute error of road surface temperature measurements in the measuring range from -50 ºC to -15 ºC inclusive: ±0.7; in the measuring range from -15 ºC to +80 ºC: ±0.2 °C
Road surface temperature measurement range at a depth of 5 cm -50 to +80 °C
Limits of permissible absolute error of road surface temperature measurements at a depth of 5 cm in the measuring range from -50 ºC to -15 ºC inclusive: ±0.7; in the measuring range from -15 ºC to +80 ºC: ±0.2 °C
Measuring range of road surface temperature -50 to +70 °C
Limits of permissible absolute error of road surface temperature measurements in the range from -50 ºC to 0 ºC inclusive: ±(0,8-0,05?t); in the range from 0 ºC to +70 ºC: ±(0,8+0,08?t), where t is the measured temperature value without taking into account the sign. °C
Water, snow, ice layer thickness measurement range For water: 1 to 10; For snow: 1 to 20; For ice: 1 to 10 mm
Limits of permissible absolute error of water, snow, ice layer thickness measurements ±0,4 mm
Measurement range of Water layer thickness 0.5 to 3 mm
Limits of permissible absolute error of water layer thickness measurements ±0,5 mm
Measuring range of relative air humidity From 1 to 100 %
Absolute error tolerance limits of relative humidity measurements in the range of temperature from -40 to +55 ? in the measuring range from 1 % to 90 % inclusive: ±2; in the measuring range from 90 % to 100 %: ±3 %
Measuring range of meteorological optical range 10 to 10000 m
Limits of permissible relative error of measurements of meteorological optical range ±10 m
Measurement range of air velocity 0,5 to 60
Limits of permissible absolute error of air velocity measurements In the range from 0.5 m/s to 5 m/s incl.: ±0.5
Limits of permissible relative error of air velocity measurements In the range from 5 m/s to 60 m/s: ±10 %
Measuring range of air flow direction 0º to 360º
Limits of permissible absolute error of airflow direction measurements ±2º
Minimum measurable amount of precipitation 0,1 mm
Limits of permissible absolute error of measurements of atmospheric precipitation quantity ±(0.1 + 0.05-X), where X is the measured value of the amount of precipitation mm
Measuring range of atmospheric precipitation intensity 0.2 to 200 mm/h.
Limits of permissible absolute error of measurements of atmospheric precipitation intensity ±(0,2+0,05-I), where I is the measured value of intensity of atmospheric precipitation, mm/hour
Electrical power supply from AC source 220±22 V
Electrical power supply from DC source 12 to 14 V
Communication interfaces USB, GSM, LAN SDI-12, RS-485, RS-232
Average service life 10 years
Weight, not more 50,5 kg

Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.

Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, Russia CIF Available to major ports worldwide EXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C) Wire Transfer (T/T) Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.