Automatic road weather station INEI
Manufacturer:
Price:
Request Quote
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Description
Automatic road meteorological station INEY is designed for automatic measurements of meteorological parameters: air temperature, roadbed temperature, ground temperature, relative humidity, speed and direction of air flow, atmospheric pressure, thickness of water layer, snow, ice on the road surface, meteorological optical range, amount and intensity of precipitation, as well as for local collection, processing and transmission of monitoring parameters to external users.
Automatic road meteorological station INEI is able to analyse the condition of the road surface to determine the amount and concentration of anti-icing agent, the amount of snow, water or moisture on the surface and the freezing temperature, as well as to warn about the presence of ice, snow and precipitation.
Automatic road meteorological station INEI is able to analyse the condition of the road surface to determine the amount and concentration of anti-icing agent, the amount of snow, water or moisture on the surface and the freezing temperature, as well as to warn about the presence of ice, snow and precipitation.
Specifications
Atmospheric pressure measuring range
26-126
Absolute error tolerance limits of atmospheric pressure measurements
± 0.03
Measuring range of air temperature
-60 to +85 °C
Limits of permissible absolute error of air temperature measurements
in the range from -60 ºC to +20 ºC on: ±(0.17-0.0028?t); in the range from +20 ºC to +85 ºC: ±(0.07+0.0025?t), where t is the measured temperature value without taking into account the sign. °C
Ground Temperature Measurement Range
-50 to +60 °C
Limits of permissible absolute error of ground temperature measurements
±0,2 °C
Measuring range of road surface temperature
-50 to +80 °C
Limits of permissible absolute error of road surface temperature measurements
in the measuring range from -50 ºC to -15 ºC inclusive: ±0.7; in the measuring range from -15 ºC to +80 ºC: ±0.2 °C
Road surface temperature measurement range at a depth of 5 cm
-50 to +80 °C
Limits of permissible absolute error of road surface temperature measurements at a depth of 5 cm
in the measuring range from -50 ºC to -15 ºC inclusive: ±0.7; in the measuring range from -15 ºC to +80 ºC: ±0.2 °C
Measuring range of road surface temperature
-50 to +70 °C
Limits of permissible absolute error of road surface temperature measurements
in the range from -50 ºC to 0 ºC inclusive: ±(0,8-0,05?t); in the range from 0 ºC to +70 ºC: ±(0,8+0,08?t), where t is the measured temperature value without taking into account the sign. °C
Water, snow, ice layer thickness measurement range
For water: 1 to 10; For snow: 1 to 20; For ice: 1 to 10 mm
Limits of permissible absolute error of water, snow, ice layer thickness measurements
±0,4 mm
Measurement range of Water layer thickness
0.5 to 3 mm
Limits of permissible absolute error of water layer thickness measurements
±0,5 mm
Measuring range of relative air humidity
From 1 to 100 %
Absolute error tolerance limits of relative humidity measurements in the range of temperature from -40 to +55 ?
in the measuring range from 1 % to 90 % inclusive: ±2; in the measuring range from 90 % to 100 %: ±3 %
Measuring range of meteorological optical range
10 to 10000 m
Limits of permissible relative error of measurements of meteorological optical range
±10 m
Measurement range of air velocity
0,5 to 60
Limits of permissible absolute error of air velocity measurements
In the range from 0.5 m/s to 5 m/s incl.: ±0.5
Limits of permissible relative error of air velocity measurements
In the range from 5 m/s to 60 m/s: ±10 %
Measuring range of air flow direction
0º to 360º
Limits of permissible absolute error of airflow direction measurements
±2º
Minimum measurable amount of precipitation
0,1 mm
Limits of permissible absolute error of measurements of atmospheric precipitation quantity
±(0.1 + 0.05-X), where X is the measured value of the amount of precipitation mm
Measuring range of atmospheric precipitation intensity
0.2 to 200 mm/h.
Limits of permissible absolute error of measurements of atmospheric precipitation intensity
±(0,2+0,05-I), where I is the measured value of intensity of atmospheric precipitation, mm/hour
Electrical power supply from AC source
220±22 V
Electrical power supply from DC source
12 to 14 V
Communication interfaces
USB, GSM, LAN SDI-12, RS-485, RS-232
Average service life
10 years
Weight, not more
50,5 kg
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Road surface condition sensor "DSPD", modification DSPD-M
View Details
Integrated atmospheric parameters sensor IWS, modification IWS-1
View Details
Small-size MRZ-3MK radiosonde
View Details
Air temperature and humidity sensor DTV-05
View Details
Wind speed and direction sensor DSNV ISAT.416136.005
View Details
Anemorumbometer SOKOL-A
View Details
Meter Sokol-TDV
View Details
Meter of medium parameters IPSES-1
View Details
Wind direction sensor DVN-03
View Details
Hardware-software complex "POZNAIKINO - Monitoring" (PAKPM)
View Details
Modular extractable perforator PMI90-02
View Details
Corrosion rate indicator KontKorr TU 3435-021-93719333-2015 (three types are produced: KontKorr-TST-ISK, KontKorr-TST-IIS, Co
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions