Addressable analogue combined fire alarm control and monitoring device PPK-02-250-2 "RUBETEK"
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Technical Specifications
Power supply from a DC source with voltage | 24 V |
---|---|
Probability of failure-free operation in 1000 h | 0.98 |
Average MTBF | 60000 |
Average service life | 10 a |
Weight | 0.7 kg |
Dimensions (L x W x H), mm | 245 x 197 x 32 |
Degree of enclosure protection | IP20 |
Relative humidity at + 40 deg. ? | 0...93 % |
Operating temperature range | -10...55 °C |
Maximum communication range (in open terrain) | SBVVBG m |
Operating frequency of the Wi-Fi interface | 2400 |
Maximum switched current at each output "OUT1" and "OUT2" | 0.45 A |
Output voltage | 24 V |
Number of outputs with line open-circuit and short-circuit monitoring | 2 pc |
Maximum switched current at the "Dry contact" output | 2 A |
Maximum voltage at the SC output | 220 V |
Number of controlled dry contact outputs | 2 pc |
Maximum line monitoring current of a freely programmable input | 0.005 A |
Maximum voltage at the freely programmable input | 20 V |
Number of freely programmable inputs | 2 pc |
Types of valves to be connected | Electromagnetic, Reversible, With return spring |
Maximum switched current of the remote control valves, OPC valves | 2 A |
Maximum communication range between CCPs and radio-channel ODRs via RF 868 MHz interface, in open terrain | 900 m |
Radiation power | Not more than 25 mW |
Channel encryption | XTEA 128bit |
Number of channels within the frequency range | 5 pc |
Operating frequency of the radio channel interface | 868 |
Number of addressable devices connected to the control panel via PLC and RF 868 MHz interface | 250 pc |
Maximum length of the PLC interface | 3000 m |
Maximum PLC load current per channel | 0.35 A |
Number of PLC interfaces | 2 pc |
Maximum interface length between RS-485 segments | 100 m |
Number of RS-485 interfaces | 2 pc |
Maximum length of the CAN interface, excluding repeaters | 100 m |
Number of control panels in the control panel system connected via CAN interface | 250 pc |
Number of occupied addresses in the CAN network | 1 pc |
Communication interface | CAN, RF 868 MHz, RS-485, PLC, Wi-Fi |
Own current consumption in "Fire" mode | Not more than 0.32 A |
Own current consumption in standby mode | Not more than 0.22 A |
Number of valves to be connected | 2 pc |
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Shipping & Payment Information
Shipping Terms
- FOB: Novorossiysk, Russia
- CIF: Available to major ports worldwide
- EXW: Manufacturer's facility, Russia
Delivery Time
- Sea freight: 30-60 days (depending on destination)
- Air freight: 14-21 days (for urgent orders)
- Production lead time: 30-90 days (depending on order size)
Payment Methods
- Letter of Credit (L/C)
- Wire Transfer (T/T)
- Escrow Services
Order Minimums
- We work with orders starting from 1 container
- You can mix different products in one container
- Volume discounts available for larger orders
Customs & Documentation Support
We provide comprehensive assistance with all export documentation, customs clearance, and logistics arrangements. Our team has extensive experience facilitating international trade with businesses in Africa, Middle East, Asia, and Latin America.
Contact Our Import Specialists
WhatsApp (Recommended)
For fastest response and immediate assistance with pricing, availability, and ordering.
+971 58 657 4796For detailed inquiries, documentation requests, and formal communications.
Send Email Inquiry info@tonzar.comRequest Call Back
Schedule a consultation with our import specialists at your convenience.
Business Hours
We're available to assist you during the following hours:
- Monday - Friday: 9:00 AM - 6:00 PM (GMT+4)
- Saturday: 10:00 AM - 2:00 PM (GMT+4)
- Sunday: Closed
Our WhatsApp support is available outside business hours for urgent inquiries.
Similar Products You May Be Interested In

Spectron-535-Exd-N-IPR-A manual fire detector
View Details
Fire detector combined smoke optical-electronic thermal maximum-differential addressable analogue IP 212/1
View Details
Fire flame detector with video module Spektron-901-Exd-N-V-HART
View Details
Fire smoke detector optical-electronic point detector explosion-proof model IP 212-116.2 Trion MK
View Details
Spectron-401-Exd-A fire flame detector
View Details
IPP-07e-330-1/2 "Helios-2 IR" explosion-proof fire flame detector
View Details
Non-addressable smoke detector IP 212-78 Aurora-DN
View Details
Fire flame detector ERIS IP-330
View Details
????????-535-Exi-???-? ???.01
View Details
Fire smoke detector optical-electronic addressable analogue IP 212-149
View Details
Thermal fire detector IP 103- 5/1-V---
View Details
IP101-07vt Fire thermal explosion-proof programmable high-temperature detector
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions