ADC digit capacity
B1/B8 2100/900 MHz
Type of construction
modular (DIN rail)
Current consumption on the internal power supply bus
0.15 A
Maximum number of expansion modules in a system with additional remote I/O modules
100
Power redundancy
built-in supercapacitor for saving current parameters and proper shutdown of the computing module
DC overvoltage protection
yes
Galvanic isolation of external sensor circuits and internal power supply circuits of computing components
yes
Installation dimensions (WxHxH), max.
B1/B8 2100/900 MHz mm
Installation dimensions (WxHxH), max.
B1/B8 2100/900 MHz mm
Installation dimensions (WxHxH), max.
B1/B8 2100/900 MHz mm
Installation dimensions (WxHxH), max.
B1/B8 2100/900 MHz mm
Installation dimensions (WxHxH), max.
B1/B8 2100/900 MHz mm
Installation dimensions (WxHxH), max.
55 mm
OS
Linux based on Ubuntu distribution with Real Time Patch
interfaces
1x RS-485, 1x Ethernet
Time synchronization
via NTP/SNTP server
Video output
1xHDMI 1.4 with HDCP 1.2
Audio input
dupont 2.54 connector on pcb for external microphone (optional)
Audio output
3.5 mm jack (optional), hdmi
Power supply voltage, direct current
24 V
ADC digit capacity
B1/B8 2100/900 MHz
Nominal range
0...1600 ohm
Galvanic insulation
500 V
Module consumption via 5 V bus
1 W
Module consumption via 24 V bus
8 W
Resolution of serial approximation ADCs
16
Polling time of all channels
0.1
thermoresistance
PT100 (2-, 3-, 4-wire) PT1000 (2-, 3-, 4-wire)
Presence of polarity reversal alarm
Yes, indication on module
Measuring current
0.0004 A
ADC digit capacity
B1/B8 2100/900 MHz
Galvanic insulation
500 V
Module consumption via 5 V bus
1 W
Module consumption via 24 V bus
8 W
Resolution of serial approximation ADCs
16
Polling time of all channels
0.1
Input resistance of current measurement channels, kOhm, not less
100000 ohm
Galvanic insulation
500 V
Module consumption via 5 V bus
1 W
Module consumption via 24 V bus
8 W
Input resistance of current measurement channels
100 ohm
Resolution of serial approximation ADCs
16
Presence of polarity reversal alarm
Yes, indication on module
Polling time of all channels
0.1
Sensor type
passive with external power supply
Sensor type
passive with external power supply
Sensor type
passive with external power supply
Permissible supply range
21...30 V
DAC resolution
B1/B8 2100/900 MHz
Module consumption via 5 V bus
1 W
Module consumption via 24 V bus
8 W
LED indication of the module status
available
Short-circuit and overcurrent protection
yes
Module consumption via 5 V bus
1 W
Module consumption via 24 V bus
8 W
LED indication of channels status
available
LED indication of the module status
available
Software contact bounce filtering
Yes, module firmware
Maximum current consumption
0.00052 A
Short-circuit and overcurrent protection
yes
Operating atmospheric pressure
84...106.7
Dielectric strength of insulation under sinusoidal AC currents
500 V
Current on buses of potential distribution, power supply of sensors and actuators (field supply)
8 A
Power supply voltage
20.4...28.8 V
Degree of protection
IP20
Maximum number of I/O modules on the CAN bus
32
Power consumption, max.
250 W
Average service life
15 year
mean time between failures
1000000
Relative humidity of the room, without condensation, not more than
95 %
Storage temperature range
-40...70 °C
Operating temperature range
-10...60 °C