Number of input/output channels per one UCC
544 pcs
Number of arrows per UCC (one or first UCC)
up to 45
Overall dimensions of UCC, mm, not more
800 × 2000 × 600 mm
Logic programme construction
unified software blocks
Availability of direct wire mode
backup control mode, optional
Number of cascadable UCCs
4 pcs
kit
UKC, SHTK, ARM DSP, ARM SHN, SGP-MS
designation
ЕРКФ.424359.002
Weight of UCC, kg, not more
300 kg
Overall dimensions SHTK, mm, not more
600 × 2000 × 600 mm
Weight of trowels, kg, not more
200 kg
Overall dimensions of DSP ARM, mm, not more
1800 × 725-750 × 1000 mm
Overall dimensions of ARM SH, mm, not more
1200 × 725-750 × 750 mm
Weight of the SN ARM, kg, not more
150 kg
Class of accommodation conditions under the influence of climatic factors according to (GOST 34012-2016)
K1
Placement category (GOST 15150-69)
UHL4
Ambient temperature, °C
from +1 to +40 °C
Relative humidity at temperature plus 25 °C
no more than 80%
Class of placement conditions under mechanical loads (GOST 34012-2016)
MS1
Protection class against access to hazardous parts and harmful effects caused by penetration of solid objects into the enclosure
IP30
Power supply unit
Guaranteed power supply system
Power supply voltage, V
24 ± 10 %
Maximum power consumption of UCC, W, no more
650 - peak value W
Maximum power consumption of the SHTK, W, not exceeding
900 - peak value W
Maximum power consumption of the DSP APM , W, max.
960 W
Maximum power consumption of ARM SN, W, not more than
480 W
Type of safety system
24 ± 10 %
Type of control system
centralized
Control programme execution cycle time, ms, not more
100
Time of reaction to external influences, s, not more
1
Method of interrogation of objects of control
cyclic
Method of forming control actions
cyclic
Method of input of control commands
sporadic
Number of relays per switch (for shunting areas)
from 6 to 8
Number of relays per switch (for stations with train operation)
from 14 to 15
Communication channel capacity at remote control of stations, Mbit/s, not less than
2
Type of LAN formed between stations when remote control is used
peer-to-peer
Type of redundant communication channels between remote stations
automatic
Number of connection points for connecting communication equipment of the SHTK when organising LAN for remote control of station
2 - physical
Time of provision of information on change of control objects at the control panel (remote control of stations) to the operating
6
Time of transmission of TOU commands from the PU to the control centre (remote control of stations), s, not exceeding
1
Transportation conditions in terms of mechanical loads (GOST 23216-78)
group L
Transportation conditions in terms of exposure to climatic factors (GOST 15150-69)
group 5 (OЖ4)
Storage conditions in terms of exposure to climatic factors (GOST 15150-69)
group 1 (L)
Warranty period of operation, one year, not less
3 year
Service life, year, not less
20 year