Output power, kVA
1600...3000
AC input voltage
3000...11000 V
Earthquake-proof version according to MSK-64 scale
最多9分(包括)
Output voltage
0...11000 V
Degree of protection
根据GOST 9.032不低于IV级
Isolation monitoring of load output circuits
可用
Thermal compensation of battery recharge voltage
不需要
Input power factor corrector
可用
Isolation transformer of the standby input and rectifier
不需要
Isolation transformer at the rectifier input
可用
RFI interference level filter
不需要
Protection against reverse current
可用
Nominal voltage
3000...11000 V
Speed, rpm in 1 s: speed decrease of speed during braking of EA, including at idle speed (1500 rpm)
50...75
Speed, r/min per 1 s: speed, r/min for 1 s: change of speed of the EA shaft rotation during regulation process, including idling
35...50
Absolute error of positioning the speed of rotation of the ED shaft in the whole range, r/min, not more than
3
Absolute error of positioning of ED shaft rotation speed in the whole range, not more than
3
Reaction time of the IF (the moment of the beginning of the change of the speed of the EA shaft) from the moment of receiving th
0.05
Measurement discreteness of the speed of the EA shaft rotation, not more than
0.05
Rated total power of IF
2000...3000
Overload capacity, for 90 s
120 %
Overload capacity, for 3 s
150 %
Measurement discreteness of the speed of the EA shaft rotation, not more than
1
Efficiency in nominal mode, not less
96.5 %
Voltage of operating power supply circuits, at frequency 50 Hz
220...380 V
IF control inputs and outputs
模拟;数字;离散
Interface language of the IF control panel
俄语
Network protocols
ModbusRTU
Protection degree of the block container according to GOST 14254, not less than
IP54
Climatic version according to GOST 15150 for closed heated premises
UHL4
Climatic version according to GOST 15150 For outdoor installation as part of block containers
U1; UHL1
Cable entry into the IF
顶部;侧面;底部
Method of inverter cooling, at IF power, kV-A up to 8000 inclusive
空气
Method of inverter cooling, at IF power, kV-A over 8000 to 17200
空气;液体
Electromagnetic compatibility GOST R 51524
C1 类
Electromagnetic compatibility GOST 30804.6.2
按质量性能标准 A
Rated supply voltage
6 kV
Deviation of frequency ?f, measured in time interval of 10 s. according to GOST 32144, during 95% of time interval of one week
5
Deviation of frequency ?f measured in time interval of 10 s according to GOST 32144, during 100 % of time interval of one week
8
Degree of protection (IP)
21
Power factor at the IF input, not less than
0.95
Pulsatility of rectification circuit on the basis of voltage inverter, not less than 6 kV
30
Voltage inverter based rectification circuit pulsatility, not less than 10 kV
48
Number of phases of mains voltage
3
Permissible deviation of supply voltage from nominal value, %
-15...10