Maximum output power of X-ray power supply unit, kW
至少50
Maximum allowable patient weight, kg
至少135
Length of the X-ray table deck, cm
超过220
Length of the X-ray table deck, cm
超过220
Detector No. 2
内置于成像支架(选择检测器 #1 时可用 - 便携式内置于成像台)
Maximum allowable patient weight, kg
至少135
Nominal size of small focal spot of X-ray radiator with beam forming device, mm
不超过 0.6
Maximum output power of X-ray power supply unit, kW
至少50
Maximum anode voltage, kV
至少 150
Emergency switch on the system control unit or on the apparatus tripod
是
Transmitter movement in longitudinal direction
是
Minimum focal length for vertical radiography stand, cm
不超过 100
Possibility of shooting without rasterization
是
Moving the deck of the radiography table in transverse direction, cm
至少22
Pixel size of X-ray image receiver, µm
不超过150
Maximum focal length to the center of the receiver for the image table, cm
不少于160
Rotating the X-ray image receiver (setting the receiver parallel to the floor surface) of the image stand for the vertical
是
Minimum focal length to the center of the receiver for the image table, cm
不超过 100
Nominal size of the large focal spot of X-ray radiator with beam forming device, mm
不超过 1.2
Detector No. 4 (optional)
否
Availability of X-ray dosimeter clinical
是
Transmitter rotation angle, deg
超过150
Angle of rotation of the detector, deg
至少90
Spatial resolution, line pairs/mm
超过2.5
Automated workplace of X-ray laboratory technician with specialized software
是
X-ray transparency table of images
固定
Width of the X-ray table deck, cm
超过75
Availability of an elevator for the deck of the imaging table
是
Movement of the X-ray table deck in longitudinal direction, cm
至少80
Range of longitudinal movement of the tube, cm
不小于140
Maximum permissible weight of the patient (if a table is available), kg
至少135
Intercom system for the exam operator to communicate with the patient
是
Transverse movement of the transmitter
是
Automated doctor's workstation with specialized software
是
Availability of an elevator for the deck of the imaging table
是
X-ray transparency table of images
固定
Intercom system for the exam operator to communicate with the patient
是
Automated workplace of X-ray laboratory technician with specialized software
是
Possibility of shooting without rasterization
是
Rotating the X-ray image receiver (setting the receiver parallel to the floor surface) of the image stand for the vertical
是
Minimum focal length for vertical radiography stand, cm
不超过 100
Maximum focal length to the center of the receiver for the image table, cm
不少于160
Minimum focal length to the center of the receiver for the image table, cm
不超过 100
Transverse movement of the transmitter
是
Moving the deck of the radiography table in transverse direction, cm
至少22
Movement of the X-ray table deck in longitudinal direction, cm
至少80
Width of the X-ray table deck, cm
超过75
Detector No. 2
内置于成像支架(选择检测器 #1 时可用 - 便携式内置于成像台)
Automated doctor's workstation with specialized software
是
Detector No. 4 (optional)
否
Range of longitudinal movement of the tube, cm
不小于140
Availability of X-ray dosimeter clinical
是
Transmitter movement in longitudinal direction
是
Nominal size of the large focal spot of X-ray radiator with beam forming device, mm
不超过 1.2
Nominal size of small focal spot of X-ray radiator with beam forming device, mm
不超过 0.6
Maximum anode current, mA
至少500毫安
Maximum anode voltage, kV
至少 150
Image Receiver Type
固定平面探测器