Automatic Rectifiers for Cathodic Protection "Energomera" V-OPE
so'm 18,900,000-60,480,000
ENERGOMERA OJSC 🇷🇺
DC/DC Voltage Converter PN4-110-24 for Railways 110V to 24V 120W
so'm 226,800-756,000
SIBKONTAKT LLC 🇷🇺
Modular Inverter Power Supplies for Galvanic Baths - NEON Types "IPG", "IPT", "IVN", "MKS
so'm 37,800,000-2,268,000,000
ELECTRO INTEL OJSC 🇷🇺
Aviation Power Converter MN108 5kW and MN107 1.5kW
so'm 22,680,000-105,840,000
Derbent Scientific Research Institute "Volna" OJSC 🇷🇺
Rectifier V-TPPD-6.3k/0.2k-1k/3k-U2 for Passenger Locomotives
so'm 189,000,000-604,800,000
ELECTRORECTIFIER PJSC 🇷🇺
High Voltage Capacitive Voltage Transformer PVE-500 MS2.727.002 TU
so'm 113,400,000-378,000,000
MARS-ENERGO LLC 🇷🇺
SibVolt 2075JD DC/AC Inverter 75/220V 2000W for Railway Use
so'm 7,560,000-22,680,000
SIBKONTAKT LLC 🇷🇺
DC-DC Voltage Converter for Electric Vehicles RUBRUKS VCGI-600-14-3
so'm 11,340,000-37,800,000
RUBRUKS LLC 🇷🇺
Voltage Converter IDPV - Efficient Power Conversion
so'm 1,134,000-4,536,000
Sergo Ordzhonikidze SEZ OJSC 🇷🇺
FAQ
•Can distribution transformers be built for my national grid parameters?
Yes. Plants wind to your primary and secondary voltages, vector group, tap range and frequency, and apply the cooling and climatic execution your site needs. Provide the network one-line data and ambient conditions; the factory returns a technical proposal with losses, impedance and dimensions for approval before production, which typically takes 8–16 weeks.
•What testing documentation accompanies a transformer?
Every unit passes routine tests — winding resistance, ratio, insulation, applied and induced voltage, losses — documented in a protocol shipped with the transformer. Type test reports for the design are available for tender files. Utility buyers can witness factory acceptance in person or by video link, which suppliers arrange routinely.
•How are lithium batteries and UPS systems shipped internationally?
Lithium-ion batteries travel as Class 9 dangerous goods: UN-certified packaging, state-of-charge limits and dangerous goods declarations, which suppliers prepare. Sea freight is the standard mode; air carries tighter restrictions. Lead-acid and VRLA batteries ship with simpler paperwork. Factor 1–2 extra weeks for DG documentation on first orders.
•Do UPS suppliers help size the system for my facility?
Yes — send the load list, required autonomy and site temperature, and the supplier proposes UPS rating, battery configuration and ventilation requirements. For data-centre and telecom projects, redundancy schemes and monitoring integration are specified at this stage. Sizing calculations are part of the quotation, not a paid extra.
•Is commissioning support available for packaged substations?
Packaged substations ship factory-assembled and tested, with installation and earthing drawings. Supervised commissioning by a factory engineer is a contract option many utility buyers take for the first units, then handle subsequent ones with their own crews. Remote support and spare-parts kits are agreed in the supply contract.
•What payment structure is usual for large electrical equipment?
Typical terms are 30–50 percent advance with the balance before shipment by bank transfer; letters of credit are workable with larger plants if banking channels are agreed early. For framework utility contracts, milestone payments tied to factory acceptance tests are common practice.