Товары — Кабели и проводка

Flexible Power Cables with Alkendiol Elastomer Insulation, KGN Type

ELKANORD тип КГН, КГНЭ

₽150-500
ООО "ОКП "ЭЛКА-КАБЕЛЬ" 🇷🇺
Compact Copper Insulated Cable KMP-EV

Кабель малогабаритный КМПЭВ

₽50-200
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Flexible Cable KGVEV/ng(A)/ng(A)-LS/ng(A)-FRLS

Кабель КГВЭВ/нг(А)/нг(А)-LS/нг(А)-FRLS

₽200-800
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Fire-resistant installation cable KUPPng(A)-FRHF

Кабель установочный КуППнг(А)-FRHF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Flexible Power Cable KGPПнг(А)-HF

Кабель силовой гибкий КГППнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Digital Access Cable TCPPt 2x2x0.52 FE Long

Кабель ТЦППт 2х2х0,52 FE Long

₽150-300
ООО "НПП "ИНФОРМСИСТЕМА" 🇷🇺
Flexible Power Cable KGVVEng(A)-LS 380/660

Кабель силовой гибкий КГВВЭнг(А)-LS 380/660

₽150-300
ООО "АЛЬФАКАБЕЛЬ" 🇷🇺
Flexible Power Cable KGVV for Mobile Equipment

Кабель КГВВ

₽50-200
АО "ЛИДЕР-КОМПАУНД" 🇷🇺
Flexible Shielded Power Cable KGE-6 for Excavators

Кабель КГЭ-6

₽150-500
ООО "КАМСКИЙ КАБЕЛЬ" 🇷🇺
Power Cable PvPug 3x95mk/95-6kV

Кабель ПвПуг 3х95мк/95-6кВ

₽1 500-2 500
АО "ЭКЗ" 🇷🇺
Flexible PVC Insulated Cable KGVBBV-HL/ng(A)-HL

Кабель КГВБбВ-ХЛ/нг(А)-ХЛ

₽150-500
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Structured Cable KSP 5e 2x2x0.5 for External Installation

Кабель КСП 5е 2х2х0,5

₽20-50
ООО "НПП "ИНФОРМСИСТЕМА" 🇷🇺
Low-Flame Hazard Power Cables VVG-Png(A)-LS

Силовые кабели ВВГ-Пнг(А)-LS

₽100-300
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Low Flame Hazard Power Cable VVГ-Pнг (A) -LS 3x4

Кабель силовой ВВГ-Пнг (А) -LS 3х4

₽30-60
ООО "АКЗ" 🇷🇺
Compact Copper Cable KMVVE for Fixed Installation

Кабель малогабаритный КМВВЭ

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Signal-Blocking Cable SBZPBbShp for Secure Communication

Кабели сигнально-блокировочные СБЗПБбШп

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺

Часто задаваемые вопросы

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.