Товары — Кабели и проводка

Low-Flame Power Cable ABVGEng(A) 0.66/1 kV

Кабель силовой АВВГЭнг(А)

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
High Voltage Power Cable AПвПу2г 1*240(гж)/95-87/150

Кабель АПвПу2г 1*240(гж)/95-87/150

₽150-250
АО "ИРКУТСККАБЕЛЬ" 🇷🇺
Power Cable APvKV - Aluminum Conductors with XLPE Insulation

Кабель АПвКВ

₽250-1 500
ООО "ЭМ-КАБЕЛЬ" 🇷🇺
Power Cable AПвЭБПнг(А)-HF with Aluminum Conductors

Кабель силовой АПвЭБПнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Power Cable for Voltage 0.66; 1kV, Model APvBГ

Кабель силовой на напряжение 0,66; 1кВ марки АПвBГ

₽150-300
АО "Самарская Кабельная Компания" 🇷🇺
Halogen-Free Power Cable APvPGb(HF)

Кабель силовой АПвПГЭнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Power Cable with Aluminum Conductor AABLSHN-G6 3x240

Кабель силовой с алюминиевой жилой ААБЛШНГ-6 3х240

₽1 500-2 500
ООО "КАМСКИЙ КАБЕЛЬ" 🇷🇺
Power Cable for Voltage up to 1kV AПвВГ

Кабель силовой на напряжение до 1кВ АПвВГ

₽150-500
ООО "ККЗ "ЕВКАБЕЛЬ" 🇷🇺
PVC Insulated Power Cable up to 1kV AVVGng(A)

Кабель силовой на напряжение до 1кВ АВВГнг(А)

₽100-300
ООО "ККЗ "ЕВКАБЕЛЬ" 🇷🇺
Low-Flame Power Cable AПвВГнг(А)-ХЛ

Кабель силовой АПвВГнг(А)-ХЛ

₽100-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺

Часто задаваемые вопросы

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.