Товары — Кабели и проводка

Power Cable up to 1 kV APvBShv

Кабель силовой на напряжение до 1кВ АПвБШв

₽200-1 000
ООО "ККЗ "ЕВКАБЕЛЬ" 🇷🇺
Power Cable AVVGng(A) - Non-Armored, PVC Insulation

Кабель силовой АВВГнг(А)

₽100-200
ООО "КАБЕЛЬНЫЙ ЗАВОД "АЛЮР" 🇷🇺
Power Cable for Voltage up to 1kV AПвВГнг(А)

Кабель силовой на напряжение до 1кВ АПвВГнг(А)

₽150-400
ООО "ККЗ "ЕВКАБЕЛЬ" 🇷🇺
Armored Power Cable AVBShv

Кабель силовой бронированный АВБШв

₽150-500
ООО "ВИМ-КАБЕЛЬ" 🇷🇺
Power Cable AVBShvng(A) with Aluminum Conductors

Кабель силовой АВБШвнг(А)

₽150-300
ООО "КАБЕЛЬНЫЙ ЗАВОД "АЛЮР" 🇷🇺
Power Cable AABLE-110 1x50 with Aluminum Conductor

Кабель силовой с алюминиевой жилой ААБЛЭ-110 1х50

₽150-250
ООО "КАМСКИЙ КАБЕЛЬ" 🇷🇺
Power Cable with Aluminum Conductors and Enhanced Protection, APvPugzh

Кабель АПвПугж

₽150-300
ООО "ЭМ-КАБЕЛЬ" 🇷🇺
Power Cable AПвПу - Aluminum Conductor with Cross-Linked Polyethylene Insulation

Кабель АПвПу

₽150-300
ООО "ЭМ-КАБЕЛЬ" 🇷🇺
Power Cable APvPngg-HF 127-220 kV

Силовой кабель АПвПнгг-HF 127-220 кВ

₽15 000-30 000
ООО "ЭСТРАЛИН ЗВК" 🇷🇺
Power Cables for Cold Climate Regions AВВГнг(А)-ХЛ

Кабели силовые для районов с холодным климатом АВВГнг(А)-ХЛ

₽80-200
АО "Самарская Кабельная Компания" 🇷🇺
Armored Power Cable APvBShv - Aluminum Conductors

Кабель силовой бронированный АПвБШв

₽150-500
ООО "ВИМ-КАБЕЛЬ" 🇷🇺
Power Cable APvPGng(A)-HF with Aluminum Conductors

Кабель силовой АПвПГнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Low Fire Hazard Power Cable AVVGng(A)-LSLTx

Кабель силовой АВВГнг(А)-LSLTx

₽100-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺

Часто задаваемые вопросы

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.