Товары — Кабели и проводка

Universal Fire-Resistant Installation Cable MKBShVng(A)-FRLS

Кабель монтажный МКБШВнг(А)-FRLS

₽150-300
ООО ПО "СЭК" 🇷🇺
Compact Installation Wires MPKMUE

Провода монтажные МПКМУЭ

₽50-200
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Flexible Copper Wiring Cable MKÉKSHVng(A)-FRLSLTx

Кабель монтажный МКЭКШВнг(А)-FRLSLTx

₽200-500
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Flexible PVC Insulated Installation Cable MKKSHV-HL

Кабель монтажный МККШВ-ХЛ

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Mounting Wires MGSHVE-OS for Electrical Installations

Провода монтажные МГШВЭ-ОС

₽150-300
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Universal Installation Cable MKESHPsng(A)-LS

Кабель монтажный МКЭШПснг(А)-LS

₽150-300
ООО ПО "СЭК" 🇷🇺
Flexible PVC Insulated Single-Conductor Cable MKESH-HL

Кабель монтажный МКЭШ-ХЛ

₽200-500
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Universal Fire-Resistant Installation Cable MKЭБШПснг(А)-FRLS

Кабель монтажный МКЭБШПснг(А)-FRLS

₽250-500
ООО ПО "СЭК" 🇷🇺
Control Cables KUPÉV-P-O

Кабели управления КУПЭВ-П-О

₽150-300
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Fire-Resistant Shielded Installation Cable HERDA-KVKng(A)-FRLS

Кабели монтажные ГЕРДА-КВКнг(А)-FRLS

₽150-300
ЗАО "КУБАНЬКАБЕЛЬ" 🇷🇺
Flexible PVC Insulated Mounting Cable MKKSHng(A)

Кабель монтажный МККШнг(А)

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Heat-resistant installation wires MPOU for electrical devices

Провода монтажные теплостойкие МПОУ

₽30-150
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Universal Installation Cable MKEKSHVng(A)

Кабель монтажный МКЭКШВнг(А)

₽150-500
ООО ПО "СЭК" 🇷🇺
Compact Insulated Installation Wires MPM-OS

Провода монтажные МПМ-ОС

₽30-80
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Flexible Halogen-Free Installation Cable MKSHng(A)-HF

Кабель монтажный МКШнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Flexible Installation Cable MKKSHVng(A)-HF

Кабель монтажный МККШВнг(А)-HF

₽150-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Universal Fire-Resistant Mounting Cable MKЭКШПснг(А)-FRLS

Кабель монтажный МКЭКШПснг(А)-FRLS

₽250-500
ООО ПО "СЭК" 🇷🇺
Flexible Halogen-Free Installation Cable MKSHng(A)-FRHF-ХЛ

Кабель монтажный МКШнг(А)-FRHF-ХЛ

₽100-300
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Flexible Halogen-Free Installation Cable MKESHng(A)-FRHF

Кабель монтажный МКЭШнг(А)-FRHF

₽200-500
ООО "КАВКАЗКАБЕЛЬ" 🇷🇺
Shielded Mounting Cable MKSHng(A)-FRHF

Кабель монтажный МКШнг(А)-FRHF

₽150-500
АО "КАБЕЛЬНЫЙ ЗАВОД "КАВКАЗКАБЕЛЬ ТМ" 🇷🇺
Universal Fire-Resistant Installation Cable MKKSHVng(A)-FRLS

Кабель монтажный МККШВнг(А)-FRLS

₽150-500
ООО ПО "СЭК" 🇷🇺
MPKMU-OS Insulated Installation Wires

Провода монтажные МПКМУ-ОС

₽50-150
АО "НП "ПОДОЛЬСККАБЕЛЬ" 🇷🇺
Universal Fire-Resistant Installation Cable MKESHVng(A)-FRLSLT

Кабель монтажный МКЭШВнг(А)-FRLSLTx

₽150-300
ООО ПО "СЭК" 🇷🇺
Fire-Resistant Installation Cables MKPsEI

Кабели монтажные МКПсЭИВ

₽150-500
ООО НПП "ИНТЕХ" 🇷🇺

Часто задаваемые вопросы

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.