Universal power cable KRUEL-SK-(E)V(E)(B,K,S)-(c)-ng(A)-LSLTx
Manufacturer:
Price:
Request Quote
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Available Models
Description
Power universal cable not spreading combustion, with reduced smoke and gas emission and low toxicity of combustion products, with cores of copper, or copper coated, or aluminium, or aluminium coated wires, with the number of cores from 1 to 10, nominal cross-section of cores from 1.0 to 1000 mm2, with insulation made of polyvinylchloride plasticate of reduced fire hazard and low toxicity of combustion products, shielded or unshielded, armoured or unarmoured, for rated voltage of 660 V and 1000 V AC 50 Hz or DC 1000 V and 1500 V, designed for transmission and distribution of electrical energy in networks and electrical installations.
Cables are used for connection of stationary consumers, as well as power connection of mobile equipment.
Cables are allowed to be used in explosive environments and at underground facilities, provided they meet the requirements for design and technical characteristics.
Cables are used for connection of stationary consumers, as well as power connection of mobile equipment.
Cables are allowed to be used in explosive environments and at underground facilities, provided they meet the requirements for design and technical characteristics.
Specifications
Mark
KRUEL-SK-(E)V(E)(B,K,S)-(c)-ng(A)-LSLTx
Design
Multiconductor TWAs (m), single wire TWAs (o), round TWAs (k), sector or segmental TWAs (c)
Cable shape
Round, flat
Core material
Copper, tinned copper(l), aluminum (A), aluminum alloy (As)
Insulation material
Polyvinyl chloride plasticate with reduced fire hazard and low toxicity of combustion products (B)
Sheath material
Water-absorbing elements (c), filled with silicone compound (pz)
Core diameter
1.13...41.6 mm
Sheath material
according to cable version
Insulation material
Polyvinyl chloride plasticate with reduced fire hazard and low toxicity of combustion products (B)
Presence of individual and/or shared metal shielding
No shield, copper tape shield (E), copper wire shield (Em), tinned copper wire shield (El), combined, aluminofoil composite material and tinned copper wire shield (Ek)
Availability of reservations
No armor, armor made of galvanized steel bands (B), aluminum alloy bands (Ba), corrugated tape laminated with polymer (Bg), galvanized steel wires (K), galvanized steel wires over outer sheath (Kg), wires of
Fire hazard class
P1b.8.2.2.1.2.
Climatic version
UHL, UHL1, CHL, CHL1, AHL, T
Operational filling
M, X, UV, Tc (Tc125, Tc200)
Ambient temperature during cable operation
-60...50 °C
Size (Number of cores x Cross-section)
1x1.0 - 1x1000; 2x1.0 - 2x240; 3x1.0 - 3x400; 4x1.0 - 4x400; 5x1.0 - 5x240; 6-10x1.0-16
Operating voltage
1 kV
Core cross section
1...1000 mm2
Number of cores
1...10 pc
Number of wires in the core
1...53 pc
Number of conductive cores
1...10
Nominal cross-section of conductive cores
1...1000 mm2
Rated AC voltage
0.66...1 kV
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Power cable VVG-Png(A)-LS 2x10
View Details
Power cable with plastic insulation for voltage 0, 66; 1kV of VBSHV brand
View Details
Fire-resistant power cable with copper conductors, with cross-linked polyethylene insulation for rated voltage of 1 kV of PvPGng
View Details
Power cable of EPRon® type with copper conductors, insulation made of ethylene propylene rubber for voltage 0,66, 1 kV of ???- b
View Details
Fire-resistant power cable VVGng(A)-FRLS-XL
View Details
Conductors of reduced fire hazard for electrical installations with voltage up to 450/750 V inclusive PUGPng(A)-NF
View Details
Power cables VVG-Png(A)-LS
View Details
Power cables with copper conductors, with insulation and sheathing made of PVC plasticate of reduced fire hazard, with reduced t
View Details
Cable VVGEng(A)-LS 2 x 10 kr (0,66) OOO "KKF" GOST
View Details
Power cable for voltage up to 1kV BCPGng(A)-HF
View Details
Power cable VBShvng(A)-FRLS
View Details
Power cable with copper conductors, with impregnated paper insulation, for voltage of 1 kV of SB grade according to TU 16.K71-26
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions