Thermoindicator electronic for cold chain control "Termotest Extra" according to TU 9452-003-62672773-2016, in versions:
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Service life of Thermotest Extra/5; Thermotest Extra/5 bis versions is not less than 5 years.
Technical Specifications
Type of product according to PP RF 616 | Medical devices, including surgical, other, not included in other groupings |
---|---|
Shelf life before activation | 2 a |
Service life of the thermometer | 5 a |
Weight | 25 g |
Length | SBVVBG mm |
Width | 32 mm |
Height | 16 mm |
Polling frequency of the monitored temperature | one reading per 0.5 or 1 min (2; 1 unit/min) |
Time zone in which Thermotest operates | 0...23 |
Indication | Liquid crystal display |
Purpose of the thermal indicator | for real-time control in the controlled object of compliance with the directive temperature interval. to detect and unambiguously establish the facts of violations of the interval "norm". for visual display in the process of control of the results of con |
Thermotest is used | during storage and transportation of thermolabile preparations at all four levels of the cold chain |
Classification depending on perceived mechanical effects according to GOST R 50444 | group 5 |
Classification depending on the potential risk of use according to GOST R 31508 and according to the order of the Ministry of He | Class 1 |
Classification by safety requirements must comply with the requirements of GOST R 50444, GOST IEC 61010-1, in accordance with GO | class III |
Safety class of Thermotest software according to GOST R IEC 62304 by severity level | class A |
Accuracy characteristics | ±0,5 °C |
Classification depending on possible consequences of failure in accordance with GOST R 50444 | class B |
Number of temperature intervals "NORMA" in the operating temperature range in Thermotest | one |
Minimum value of the "NORM" interval | 3 °C |
Maximum value of the NORM interval | 110 °C |
Error of setting the temperature limits of the "NORMA" interval | ±0.5 °C |
Minimum value of temperature and time interval of violations by temperature parameter | 2.5 °C |
Maximum value of temperature and time interval of violations by temperature parameter | 107 °C |
Minimum value of temperature-time interval of violations by time parameter | 30 |
Maximum value of temperature-time interval of violations by time parameter | 99 |
Time reference measurement error | ± 0,001 % |
Number of temperature and time intervals of violations set in the operating temperature range in Thermotest | 0...9 |
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Shipping & Payment Information
Shipping Terms
- FOB: Novorossiysk, Russia
- CIF: Available to major ports worldwide
- EXW: Manufacturer's facility, Russia
Delivery Time
- Sea freight: 30-60 days (depending on destination)
- Air freight: 14-21 days (for urgent orders)
- Production lead time: 30-90 days (depending on order size)
Payment Methods
- Letter of Credit (L/C)
- Wire Transfer (T/T)
- Escrow Services
Order Minimums
- We work with orders starting from 1 container
- You can mix different products in one container
- Volume discounts available for larger orders
Customs & Documentation Support
We provide comprehensive assistance with all export documentation, customs clearance, and logistics arrangements. Our team has extensive experience facilitating international trade with businesses in Africa, Middle East, Asia, and Latin America.
Contact Our Import Specialists
WhatsApp (Recommended)
For fastest response and immediate assistance with pricing, availability, and ordering.
+971 58 657 4796For detailed inquiries, documentation requests, and formal communications.
Send Email Inquiry info@tonzar.comRequest Call Back
Schedule a consultation with our import specialists at your convenience.
Business Hours
We're available to assist you during the following hours:
- Monday - Friday: 9:00 AM - 6:00 PM (GMT+4)
- Saturday: 10:00 AM - 2:00 PM (GMT+4)
- Sunday: Closed
Our WhatsApp support is available outside business hours for urgent inquiries.
Similar Products You May Be Interested In

High-frequency electrosurgical instruments according to SHGID.942416.001TU. Holder (cable) of bipolar instruments (electrodes)
View Details
Medical isolating non-sterile clothing set
View Details
Modular robotic exoskeleton for medical use Remotion
View Details
"Sterile sorption napkin" according to TU 32.50.50-007-51276525-2019, size 35x65 mm
View Details
Disposable medical polymer sterile 60 ml container with screw cap.
View Details
Medical wall console Caduceus (CADUCEUS) CN1
View Details
Therapeutic multilayer device based on metallised film "RITM-ULM" / Shorts
View Details
Automatic apparatus for aerosol disinfection AERO-DEZ-"KRONT" according to TU 32.50.50-072-11769436-2018.
View Details
Disposable surgical gown sterile Eurostandard
View Details
Medical combined single-section mattress MMK-01 Comfort plus
View Details
Container for collection, storage, transport and disposal of cutaneous waste MK-01 according to TU 9398-001-44941910-2015, singl
View Details
Disposable polyethylene shoe covers
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions