Description
Fire smoke detector linear explosion-proof. Distinctive features of this modification: single-position version; operating distance from 8 to 60, to 80, to 100 metres; the detector has the explosion protection marking "0Ex ia II CT6 Ga" and intrinsic safety parameters: "Li: 1 µGn, Ci: 1000 pF, Ui: 30 B, Ii: 25 mA, Pi: 0.75 W"; reflector IPDL-Ex has the explosion protection marking "II Ga T6 X". ??212-75?? is a single-position linear explosion-protected fire detector consisting of a transceiver, hermetic enclosure and reflector reflector. In the transceiver, the optical channels are separated and isolated in a two-chamber optical system. As a reflector-reflector in ??212-75?? a highly effective cataphone (light-reflector) is used, which is able to fulfil its functions even if its surface is deflected relative to the optical beam by 10 - 15 degrees. The output pads and the switch for setting the tactics of operation are located in the hermetic box.
Specifications
Range of possible distances between the transceiver and the reflector-reflector
8...100 m
Maximum possible width of the space to be protected by one detector
9 m
Maximum possible room area protected by one detector
900
Detector supply voltage
10...30 V
Current consumed by the detector in the "Normal" mode,not more than
0.001 A
Current consumed by the detector in the "Attention" signaling mode, max.
0.01 A
Current consumed by the detector in the "Fire" signal generation mode, not more than
0.025 A
Current consumed by the detector in the "Fault" signaling mode, not more than
0.001 A
Current surge value at formation of the output signal "Attention"
0.00675...0.00825 A
Maximum possible duration of interruptions or polarity reversals of the supply voltage that do not affect normal operation
100
Minimum permissible power interruption interval frequency
4
Minimum required duration of power failure to ensure resetting of recorded notifications
2
Maximum inertia of detector actuation (by signals "Attention" and "Fire")
10
Typical inertia of detector operation (for "Attention" and "Fire" signals)
5
Inertia of "Fault" notification fixation in the "Fault - memory" mode
3...5
Inertia of "Fault" notification fixation in the "Fault - tolerance" mode
3...5
Inertia of "Fault" notification fixation in the "Fault - Beam" mode
6.5...7.5
Inertia of "Fault" notification fixation in the "Fault - excess" mode
40...60
Inertia of "Fault" notification fixation in the "Fault - Reduction" mode
40...60
Weight of the transceiver, not more than
0.42 kg
Weight of a standard reflector-reflector, not more than
0.45 kg
Weight of the reduced reflector-reflector, not more than
0.07 kg
Degree of protection of the shell according to GOST 14254, IP
65
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Share your requirements for a quick response!
Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer
Delivery & Payment
Shipping Terms
Delivery Time
Sea freight: 30-60 days (depending on destination)
Air freight: 14-21 days (for urgent orders)
Payment Methods
Similar Products You May Be Interested In

Radio channel addressable manual fire detector IP 513-08-A "Astra-Prime-4551"
View Details
Fire smoke detector optical-electronic IP 212-141
View Details
Maximum-differential addressable radio-channel thermal point fire detector IP101-04-A1R "Astra-Prime-4351"
View Details
Fire thermal point detector Spektron-101-R-Exd-A-Modbus
View Details
Fire smoke detector optical-electronic autonomous IP 212-50M
View Details
Non-addressable smoke detector IP 212-78 Aurora-DN
View Details
Maximum differential addressable analogue thermal fire detector (black) IP 101-102-A1R/Bl "RUBETEK"
View Details
Fire smoke detector IP 212-64
View Details
Spectron-804-Modbus fire flame detector
View Details
Fire smoke detector optical-electronic addressable analogue IP 212-149
View Details
Fire detector manual addressable radio channel IP 506-1-A IPR-PRO sp. L
View Details
Switching module MK-1 "RUBETEK"
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions