Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with automatic switching of arms (2 arms for 10 cylinders)

Manufacturer:
Price: Request Quote

Bulk pricing available

FOB, CIF & EXW terms available

Key Highlights

  • Made in Russia - engineered for durability
  • Suitable for challenging environments
  • Lower cost of ownership than European alternatives
  • Bulk orders available with volume discounts
  • Documentation and customs clearance assistance provided

Available Models

Nitrous oxide bypass double-arm gas ramp CADUCEUS with mechanical arm changeover (2 arms of 14 cylinders) Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with mechanical arm changeover (2 arms of 8 cylinders) Gas ramp CADUCEUS double-shoulder bypass for nitrous oxide with mechanical arm changeover (2 arms of 12 cylinders) Gas ramp CADUCEUS double-shoulder bypass ramp for carbon dioxide with mechanical switching of arms (2 arms for 3 cylinders) Gas ramp CADUCEUS double-shoulder bypass for oxygen with mechanical arm changeover (2 arms of 9 cylinders)
Nitrous oxide bypass double-arm gas ramp CADUCEUS with mechanical arm changeover (2 arms of 8 cylinders) Gas ramp CADUCEUS double-shoulder bypass for oxygen with mechanical arm changeover (2 arms with 4 cylinders) Nitrous oxide bypass double-shoulder CADUCEUS gas ramp with automatic arm changeover (2 arms of 17 cylinders) Gas ramp CADUCEUS double-shoulder by-pass for oxygen with automatic switching of arms (2 arms for 1 cylinder), exec. CADUCEUS single arm nitrous oxide gas discharge ramp (1 arm for 7 cylinders) Nitrous oxide bypass double-arm gas ramp CADUCEUS with mechanical arm changeover (2 arms of 18 cylinders) Gas ramp CADUCEUS double-shoulder bypass ramp for carbon dioxide with mechanical switching of arms (2 arms for 2 cylinders). CADUCEUS single arm gas discharge ramp for oxygen (1 arm for 3 cylinders) Gas ramp CADUCEUS double-shoulder bypass for nitrous oxide with automatic arm changeover (2 arms of 11 cylinders) CADUCEUS single arm gas discharge ramp for oxygen (1 arm for 2 cylinders) Gas ramp CADUCEUS double-shoulder bypass for nitrous oxide with mechanical arm changeover (2 arms of 9 cylinders) Nitrous oxide bypass double-arm CADUCEUS gas ramp with automatic arm changeover (2 arms of 18 cylinders) Gas ramp CADUCEUS double-shoulder bypass ramp for carbon dioxide with automatic switching of arms (2 arms for 3 cylinders) CADUCEUS single-shoulder gas discharge ramp for oxygen (1 arm for 4 cylinders), enclosure version Nitrous oxide bypass double-arm gas ramp CADUCEUS with automatic arm switching (2 arms of 7 cylinders) CADUCEUS single-shoulder gas discharge ramp for oxygen (1 arm for 6 cylinders), cabinet version Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with automatic arm changeover (2 arms of 8 cylinders) Gas ramp CADUCEUS double-shoulder bypass ramp for oxygen with mechanical arm changeover (2 arms of 7 cylinders) CADUCEUS single arm nitrous oxide gas discharge ramp (1 arm for 9 cylinders) Nitrous oxide bypass double-arm gas ramp CADUCEUS with mechanical arm changeover (2 arms with 4 cylinders) Nitrous oxide bypass double-shoulder CADUCEUS gas ramp with automatic arm changeover (2 arms with 5 cylinders) CADUCEUS gas ramp double-shoulder bypass for nitrous oxide with automatic arm changeover (2 arms of 15 cylinders) Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with automatic arm switching (2 arms with 4 cylinders) Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with automatic switching of arms (2 arms for 2 cylinders) Gas ramp CADUCEUS double-shoulder overflow ramp for oxygen with automatic switching of arms (2 arms with 3 cylinders), exec. CADUCEUS single arm gas discharge ramp for oxygen (1 arm for 8 cylinders), cabinet version

Description

The CADUCEUS two-shoulder ramps for cylinders are distribution systems designed for uninterrupted supply of gas to consumers. It is used as both primary and backup source of therapeutic gases in the medical field, as well as for working with technical oxygen, nitrous oxide or carbon dioxide in various industries.

CADUCEUS bypass ramps are designed with two independent manifolds, one of which is a priority manifold and the other one is a backup manifold. In case of pressure drop in the priority manifold, switching to the backup battery will take place. Automatic or mechanical switching units can be connected to a signalling panel informing the technical staff about the need to change the cylinders in one of the manifolds.

CADUCEUS double arm ramps are designed to connect from 1 to 40 cylinders, depending on the gas used. Depending on the technical possibilities, they can be installed in a cabinet.

Specifications

Inlet pressure, MPa
20 MPa
Output pressure, MPa
0.4...0.6 MPa
Material of parts in contact with oxygen
Brass
Safety valve actuation pressure, MPa
1.5 MPa
Save Your Time

Share your requirements for a quick response!

Instant response in 15 minutes
Best wholesale prices guaranteed
Direct from manufacturer

Delivery & Payment

Shipping Terms

FOB Novorossiysk, Russia CIF Available to major ports worldwide EXW Manufacturer's facility, Russia

Delivery Time

Sea freight: 30-60 days (depending on destination) Air freight: 14-21 days (for urgent orders)

Payment Methods

Letter of Credit (L/C) Wire Transfer (T/T) Escrow Services

Similar Products You May Be Interested In

Verified Suppliers

All products are sourced directly from authorized Russian manufacturers

Quality Assurance

Products meet international quality standards with proper certification

Global Shipping

Reliable logistics solutions to deliver products to your location

Secure Payments

Multiple secure payment options to facilitate international transactions

Your callback request has been received. We'll contact you shortly.