
Central control module of automatic voice announcement system RECOR CMU-200
Bulk pricing available
FOB, CIF & EXW terms available
Key Highlights
- Made in Russia - engineered for durability
- Suitable for challenging environments
- Lower cost of ownership than European alternatives
- Bulk orders available with volume discounts
- Documentation and customs clearance assistance provided
Technical Specifications
Number of fire alarm and activation inputs | 10 pc |
---|---|
Number of connected public address lines (not including duty personnel line) | 2 pc |
Type of supported non-volatile memory (memory card types) | MMC, SD, SDHC |
Maximum memory card capacity | 32 |
Rated output power | 200 W |
Nonlinear distortion at rated output power, not more than | 1 % |
Line output voltage at rated output power | 100 V |
Amplifier bandwidth, 3 dB level | 70...20000 |
Duty personnel line load capacity | 10 W |
Nominal signal level on line inputs | 0.2 V |
Input impedance rating for line inputs | 600 ohm |
Number of stages of microphone headset sensitivity adjustment | 10 pc |
Number of stages of volume control in broadcast mode | 10 pc |
Number of regulation steps independently for each zone | 4 pc |
Number of contact groups for connection of fire evacuation actuators type ?? "dry contact" | 2 pc |
Number of contact groups for connection of fire evacuation actuators of type NC "dry contact". | 2 pc |
Switching load limit for switching on of fire evacuation actuators | 5A, 240V |
Switching load limit when switching on the external line of light boards | 5A, 240V |
Type of external contactor for activation of fire alarm inputs and triggering of CS notification | "dry contact" |
Power consumption from 220 V power supply in standby mode, not more than | 10 |
Power consumption from 220 V power supply in the mode of sound signal broadcasting, not more than | 250 |
Rated voltage of the backup power supply | NZ-150-14,5 V |
Current consumption from the backup power supply in the standby mode, not more than | 0.2 A |
Maximum current consumption from the backup power source | 5 A |
Open-circuit and short-circuit monitoring of input fire alarm loops, integrity monitoring of broadcast lines, connected | availability |
The unit automatically switches to the backup power supply when the main power supply fails and automatically returns to the bac | availability |
Resistance between the protective earth clamp and every metallic part of the device which can be touched. | 0.1 ohm |
Insulation resistance of power supply circuits from the earthed parts of the device, not less than | 50 megohms ohm |
Electrical insulation between mains circuits and earthed parts of the device withstands without breakdown for 1 m | 1.5 kV Ampl. |
Level of acoustic noises not more than | 25 dBA |
Designs of component parts of the device comply with the requirements of GOST 28601.3, and provides its installation in 19-inch | Compliance |
Overall dimensions (length x height x depth) of the device components do not exceed | 483 x 88.5 (2U) x 430 mm |
Weight of the device does not exceed | 10 kg |
Assignment | Automatic control of speech warning and evacuation control system RECOR |
Note: All specifications are provided by the manufacturer and may be subject to change. Please contact us to confirm the latest specifications before placing your order.
Shipping & Payment Information
Shipping Terms
- FOB: Novorossiysk, Russia
- CIF: Available to major ports worldwide
- EXW: Manufacturer's facility, Russia
Delivery Time
- Sea freight: 30-60 days (depending on destination)
- Air freight: 14-21 days (for urgent orders)
- Production lead time: 30-90 days (depending on order size)
Payment Methods
- Letter of Credit (L/C)
- Wire Transfer (T/T)
- Escrow Services
Order Minimums
- We work with orders starting from 1 container
- You can mix different products in one container
- Volume discounts available for larger orders
Customs & Documentation Support
We provide comprehensive assistance with all export documentation, customs clearance, and logistics arrangements. Our team has extensive experience facilitating international trade with businesses in Africa, Middle East, Asia, and Latin America.
Contact Our Import Specialists
WhatsApp (Recommended)
For fastest response and immediate assistance with pricing, availability, and ordering.
+971 58 657 4796For detailed inquiries, documentation requests, and formal communications.
Send Email Inquiry info@tonzar.comRequest Call Back
Schedule a consultation with our import specialists at your convenience.
Business Hours
We're available to assist you during the following hours:
- Monday - Friday: 9:00 AM - 6:00 PM (GMT+4)
- Saturday: 10:00 AM - 2:00 PM (GMT+4)
- Sunday: Closed
Our WhatsApp support is available outside business hours for urgent inquiries.
Similar Products You May Be Interested In

Light siren Mars 12-24-SP
View Details
DC-F Indication and control unit
View Details
LPM-2-IP30 RS-485 line protection device
View Details
Redut-Net-GSM" alarm control panel VDEK.425511.001
View Details
Speech ceiling siren "Verb PN-5"
View Details
AMK-IP30 Address module
View Details
Fire control device S-KLD-2
View Details
Local communication unit "Trombon SORS-LBS" version C
View Details
Combined alarm and fire alarm siren MAYAK-220-K
View Details
AMC-DIN Address module
View Details
Light siren Mars 12-24-SP-M1
View Details
AMZ-8-IP30 Address module
View DetailsVerified Suppliers
All products are sourced directly from authorized Russian manufacturers
Quality Assurance
Products meet international quality standards with proper certification
Global Shipping
Reliable logistics solutions to deliver products to your location
Secure Payments
Multiple secure payment options to facilitate international transactions