Rated output power
200 واط
Number of fire alarm and activation inputs
10 قطعة
Number of connected public address lines (not including duty personnel line)
2 قطعة
Type of supported non-volatile memory (memory card types)
MMC, SD, SDHC
Maximum memory card capacity
32
Nonlinear distortion at rated output power, not more than
1 ٪
Line output voltage at rated output power
100 فولت
Amplifier bandwidth, 3 dB level
70...20000
Duty personnel line load capacity
10 واط
Nominal signal level on line inputs
0.2 فولت
Input impedance rating for line inputs
600 ohm
Number of stages of microphone headset sensitivity adjustment
10 قطعة
Number of stages of volume control in broadcast mode
10 قطعة
Number of regulation steps independently for each zone
4 قطعة
Number of contact groups for connection of fire evacuation actuators type ?? "dry contact"
2 قطعة
Number of contact groups for connection of fire evacuation actuators of type NC "dry contact".
2 قطعة
Switching load limit for switching on of fire evacuation actuators
5أ, 240ف
Switching load limit when switching on the external line of light boards
5أ, 240ف
Type of external contactor for activation of fire alarm inputs and triggering of CS notification
"جهد جاف"
Power consumption from 220 V power supply in standby mode, not more than
10
Power consumption from 220 V power supply in the mode of sound signal broadcasting, not more than
250
Rated voltage of the backup power supply
NZ-150-14,5 فولت
Current consumption from the backup power supply in the standby mode, not more than
0.2 أمبير
Maximum current consumption from the backup power source
5 أمبير
Open-circuit and short-circuit monitoring of input fire alarm loops, integrity monitoring of broadcast lines, connected
توافر
The unit automatically switches to the backup power supply when the main power supply fails and automatically returns to the bac
توافر
Resistance between the protective earth clamp and every metallic part of the device which can be touched.
0.1 ohm
Insulation resistance of power supply circuits from the earthed parts of the device, not less than
50 مΩ ohm
Electrical insulation between mains circuits and earthed parts of the device withstands without breakdown for 1 m
1.5 كيلوفولت فعلي
Level of acoustic noises not more than
25 ديسبل A
Designs of component parts of the device comply with the requirements of GOST 28601.3, and provides its installation in 19-inch
امتثال
Overall dimensions (length x height x depth) of the device components do not exceed
483 × 88.5 (2U) × 430 مم
Weight of the device does not exceed
10 كغ
الغرض
التحكم التلقائي في نظام الإنذار الصوتي وإدارة الإخلاء RECHOR