Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±15% ±2 EMR in measuring range 0.02-2.00 A at AM signals with carrier frequencies 4545 Hz, 5000 Hz, 5555 Hz (TRC4)
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-2.00 A at FM signals with carrier frequencies 475 Hz, 525 Hz, 575 Hz, 625 Hz, 675 Hz, 725 Hz, 775 Hz, 825 Hz, 875 Hz, 925 Hz.
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR over a measurement range of 0.02-2.00 A at AM signals with carrier frequencies of 420 Hz, 480 Hz, 580 Hz, 720 Hz, 780 Hz (TRCZ)
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-EN signals with carrier frequency 174.38Hz
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-N signals with frequency 25Hz, 50Hz, 75Hz, measured without taking into account pauses between pulses
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±12% ±2 EMR over the measuring range 20.0-200 A at continuous AC signals of 25Hz, 50Hz, 75Hz frequency
Limits of permissible basic errors of the device when measuring AC RMS using a current converter (current meter)
±10% ±2 EMR over a measuring range of 0.02-20.0 A at continuous AC signals of 25Hz, 50Hz, 75Hz
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range 0.02-2.00 A at AM signals with carrier frequencies 4545 Hz, 5000 Hz, 5555 Hz (TRC4)
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-2.00 A at FM signals with carrier frequencies 475 Hz, 525 Hz, 575 Hz, 625 Hz, 675 Hz, 725 Hz, 775 Hz, 825 Hz, 875 Hz, 925 Hz.
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR over a measurement range of 0.02-2.00 A at AM signals with carrier frequencies of 420 Hz, 480 Hz, 580 Hz, 720 Hz, 780 Hz (TRCZ)
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-EN signals with carrier frequency 174.38Hz
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR in the measuring range of 0.02-20.0 A for ALS-N signals with frequency 25Hz, 50Hz, 75Hz, measured without taking into account pauses between pulses
Tolerance limit of the basic error of the device when measuring AC RMS by superimposing it on the rail head of P65 type with ?
±10% ±2 EMR over a measuring range of 0.02-20.0 A at continuous AC signals of 25Hz, 50Hz, 75Hz
The device, when connected to the AC converter (current measuring clamps), provides the ability to
Measurements in rail jumpers, without breaking the electric circuit, of alternating current of sinusoidal form with frequency 25Hz, 50Hz, 75Hz in the range from 0,02 to 200A, at frequency 175Hz in the range from 0,02 to 20A, and at frequencies higher than
The device provides status indication
autonomous power supply (when the device is switched on), its charging process, selection frequency, input signal AC values, presence of input signal manipulation, value of permanent magnetic field induction and overload of input measuring devices
The device has the function of displaying spectrogram of signal levels of working frequencies in logarithmic scale of amplitude
0.02...20 ?
The device has the function of decoding ALSN-EN codes.
At the frequency 174.38 Hz with twofold fachoraznostnyh modulation in the form of modified Bauer code. In this case the decoded code in hexadecimal system of calculation on the first and second subchannels is displayed on the screen of the device, the numb
The device has the function of decoding and displaying the type of transmitter used.
KPT-5(8), KPT-7(9) and KPT-11
The device has a function of decoding and displaying codes
"?", "?" and "??" ALSN signals
The device has the function of rail magnetisation control by indication of permanent magnetic field induction on the rail surfac
In the range of ± 20 mT and resolution of 0.1 mT with measurement error ± 3 mT
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
In the range from 60 ms to 240 ms with an error of ± 12 ms
Operating frequencies of the device, bank 1 contains frequencies
5555
Operating frequencies of the device, bank 2 contains frequencies
925
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
in the range from 60 ms to 240 ms with error ± 8 ms
The device has the function of measuring the duration of the first interval between the pulses of codes "Z" and "Zh" of ALSN sig
In the range from 60 ms to 240 ms with error ±12 ms
The device has the function of measuring the pause duration between the pulses of the code "KZh" at the signal frequency of 25,
60...1200
The instrument is powered by a lithium-polymer battery with rated voltage
3.7 V
Continuous operation time from a fully charged battery at ambient temperature from 0 to 40°C, not less than
B1/B8 2100/900 MHz
Average lifetime of the device
8 a
Average MTBF, not less than
30000
Overall dimensions
160x90x42 mm
Weight of the device, not more
0.55 kg
Range of signalling currents in the rail line at input frequency 25, 50, 75 Hz
0.2...20 A
Range of signalling currents in the rail line at an input signal frequency of 175 Hz
0.02...20 A
Range of signalling currents in the rail line at input signal frequency 420, 480, 580, 720, 780, 4545, 5000, 5555 Hz
0.02...2 A
Range of signal currents in the rail line at input signal frequency 475, 525, 575, 625, 675, 725, 775, 825, 875, 925 Hz
0.02...2 A