产品 — 电缆与布线

Flexible PVC Insulated Wire 2x0.75mm

Flexible PVC Insulated Wire 2x0.75mm

¥0.86-3.46
SEVERSKKABEL LLC 🇷🇺
Flexible PVC Electric Cable 3x0.5 mm²

Flexible PVC Electric Cable 3x0.5 mm²

¥1.08-3.46
SEVERSKKABEL LLC 🇷🇺
PVC Insulated Low Smoke Copper Cable 1x16(N)-450/750

PVC Insulated Low Smoke Copper Cable 1x16(N)-450/750

¥3.02-10.80
SEVERSKKABEL LLC 🇷🇺
PVC Insulated Copper Wire 3x1.5mm

PVC Insulated Copper Wire 3x1.5mm

¥1.08-3.46
SEVERSKKABEL LLC 🇷🇺
Flexible PVC Insulated Copper Wire 4x1

Flexible PVC Insulated Copper Wire 4x1

¥1.08-3.89
SEVERSKKABEL LLC 🇷🇺
Copper Wire with PVC Insulation 3x4

Copper Wire with PVC Insulation 3x4

¥2.16-12.96
SEVERSKKABEL LLC 🇷🇺
PVC Insulated Copper Wire 1x6 (RE) 450/750V

PVC Insulated Copper Wire 1x6 (RE) 450/750V

¥1.08-3.46
SEVERSKKABEL LLC 🇷🇺
Low Fire Hazard PVC Insulated Copper Wire 1x4(N)-450/750

Low Fire Hazard PVC Insulated Copper Wire 1x4(N)-450/750

¥1.08-3.46
SEVERSKKABEL LLC 🇷🇺
Low Fire Hazard PVC Insulated Copper Wire 1x10(N)-450/750

Low Fire Hazard PVC Insulated Copper Wire 1x10(N)-450/750

¥2.16-12.96
SEVERSKKABEL LLC 🇷🇺
Flexible PVC Insulated Copper Wire 4x0.75 mm²

Flexible PVC Insulated Copper Wire 4x0.75 mm²

¥0.86-3.46
SEVERSKKABEL LLC 🇷🇺
PVC Insulated Copper Wire 1x1.5(N) - 450/750V

PVC Insulated Copper Wire 1x1.5(N) - 450/750V

¥1.08-3.46
SEVERSKKABEL LLC 🇷🇺
Low Smoke PVC Insulated Copper Wire 1x4(RE)-450/750

Low Smoke PVC Insulated Copper Wire 1x4(RE)-450/750

¥2.16-12.96
SEVERSKKABEL LLC 🇷🇺

发布您的采购需求

从认证供应商获取报价

节省时间
Power Cable KGT-P-HL 4x0.75 (PE) 220/380-2

Power Cable KGT-P-HL 4x0.75 (PE) 220/380-2

¥2.16-8.64
SEVERSKKABEL LLC 🇷🇺
Power Cable KGT-P-HL 1x50 220/380-2 for Mobile Machines

Power Cable KGT-P-HL 1x50 220/380-2 for Mobile Machines

¥4.32-17.28
SEVERSKKABEL LLC 🇷🇺

常见问题

How do Russian cable types correspond to IEC designations?
Construction principles match: VVG corresponds to copper PVC-insulated power cable of the IEC 60502-1 type, AVBbShv to armoured aluminium cable, and SIP to aerial bundled conductor. Cross-sections follow the same square-millimetre series. Suppliers issue comparison sheets and full construction drawings so your engineers can approve equivalence against project specifications.
What is the minimum order — can I buy less than a full drum?
The drum is the practical unit: cutting opens a factory length and most plants avoid it for small remnants. However, plants will wind custom lengths to order — say, 12 drums of 350 metres to match your feeder runs — which is more useful than buying standard lengths and generating offcuts. Project lots start around 5–10 km total.
Are fire-rated and halogen-free executions available?
Yes. Most power and control families come in low-smoke halogen-free (ng-LS, ng-HF) and fire-resistant (FR) executions, tested for flame spread, smoke density and circuit integrity under fire. State the fire performance class your code requires and the plant will match it and attach the corresponding test protocols.
What documentation supports a utility tender submission?
Plants provide type test protocols, routine test certificates per drum, EAC conformity declarations, construction drawings and ISO 9001 factory certification. For medium voltage cable, partial discharge and voltage test records are included. This package normally satisfies tender technical files; specific national homologation, where required, is discussed case by case.
How is cable shipped and how long does it take?
Drums load into containers or open wagons; a 40-foot container carries roughly 15–25 tonnes of cable depending on drum sizes. Production of non-stock positions takes 2–5 weeks. Trucking to Central Asia adds 7–14 days; sea freight from Novorossiysk or St. Petersburg to the Gulf or East Africa runs 25–45 days.
Can conductors be supplied in aluminium to cut project cost?
Yes, and this is a major lever: aluminium low voltage cable, with 531 listings here, prices well below copper for distribution feeders where the larger cross-section is acceptable. Suppliers will recalculate your copper schedule into aluminium equivalents, showing the cross-section conversion and the cost difference per kilometre, so you can decide line by line.