产品 — 电源与配电

Current Transformer for Signal Transmission TSHLG-0.66

Current Transformer for Signal Transmission TSHLG-0.66

¥648-4,320
SZTT OJSC 🇷🇺
Laboratory Voltage Transformers NLL-15, NLL-35

Laboratory Voltage Transformers NLL-15, NLL-35

¥6,480-25,920
SZTT OJSC 🇷🇺
Current Transformers TSHL-0.66; TSHL-0.66-I; TSHL-0.66-II

Current Transformers TSHL-0.66; TSHL-0.66-I; TSHL-0.66-II

¥64.80-604.80
SZTT OJSC 🇷🇺
Current Transformers TShP-0.66 for Accurate Metering

Current Transformers TShP-0.66 for Accurate Metering

¥648-2,160
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOLPM(I)-6(10) kV

Grounding Voltage Transformers ZNOLPM(I)-6(10) kV

¥648-2,592
SZTT OJSC 🇷🇺
Non-Grounded Voltage Transformers NOL.08-6(10)M

Non-Grounded Voltage Transformers NOL.08-6(10)M

¥648-2,592
SZTT OJSC 🇷🇺
Non-Earthed Voltage Transformers NOL-3 kV

Non-Earthed Voltage Transformers NOL-3 kV

¥6,480-25,920
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL.01P(I)-20 kV

Grounding Voltage Transformers ZNOL.01P(I)-20 kV

¥648-2,592
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL.01PMI-35

Grounding Voltage Transformers ZNOL.01PMI-35

¥1,080-4,320
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL.06-27(35) (ZNOLÉ-35)

Grounding Voltage Transformers ZNOL.06-27(35) (ZNOLÉ-35)

¥6,480-25,920
SZTT OJSC 🇷🇺

发布您的采购需求

从认证供应商获取报价

节省时间
Grounding Voltage Transformers ZNOL.01PMI-6(10) kV

Grounding Voltage Transformers ZNOL.01PMI-6(10) kV

¥1,080-3,888
SZTT OJSC 🇷🇺
Non-Grounded Voltage Transformers NOL-6(10) kV

Non-Grounded Voltage Transformers NOL-6(10) kV

¥3,240-12,960
SZTT OJSC 🇷🇺
Non-grounded Voltage Transformer NOLP-6(10)M

Non-grounded Voltage Transformer NOLP-6(10)M

¥648-2,592
SZTT OJSC 🇷🇺
Grounded Voltage Transformer ZNOL.03-6(10) kV

Grounded Voltage Transformer ZNOL.03-6(10) kV

¥648-2,160
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL-6(10)kV

Grounding Voltage Transformers ZNOL-6(10)kV

¥1,080-3,888
SZTT OJSC 🇷🇺
Non-Grounded Voltage Transformers NOL.12-0.38(0.69) kV

Non-Grounded Voltage Transformers NOL.12-0.38(0.69) kV

¥648-2,592
SZTT OJSC 🇷🇺
Non-grounding Voltage Transformers NOL-6(10)M IV

Non-grounding Voltage Transformers NOL-6(10)M IV

¥648-2,592
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL.06-3 kV

Grounding Voltage Transformers ZNOL.06-3 kV

¥1,080-3,888
SZTT OJSC 🇷🇺
Non-grounded Voltage Transformers NOL.11-6.O5

Non-grounded Voltage Transformers NOL.11-6.O5

¥648-2,160
SZTT OJSC 🇷🇺
Non-Grounded Voltage Transformers NOL-35 III

Non-Grounded Voltage Transformers NOL-35 III

¥1,080-3,888
SZTT OJSC 🇷🇺
Grounded Voltage Transformers ZNOL.06-6(10;15;20;24;27) kV

Grounded Voltage Transformers ZNOL.06-6(10;15;20;24;27) kV

¥1,296-12,960
SZTT OJSC 🇷🇺
Laboratory Voltage Transformers NLL-3

Laboratory Voltage Transformers NLL-3

¥6,480-25,920
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOLP-6(10) kV

Grounding Voltage Transformers ZNOLP-6(10) kV

¥1,080-3,888
SZTT OJSC 🇷🇺
Non-Earthed Voltage Transformers NOL-20, NOL-35

Non-Earthed Voltage Transformers NOL-20, NOL-35

¥648-2,592
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL-35 III

Grounding Voltage Transformers ZNOL-35 III

¥6,480-21,600
SZTT OJSC 🇷🇺
Laboratory Voltage Transformers NLL-6, NLL-10, NLL-35-6

Laboratory Voltage Transformers NLL-6, NLL-10, NLL-35-6

¥648-4,320
SZTT OJSC 🇷🇺
Grounding Voltage Transformers ZNOL.02-27 III

Grounding Voltage Transformers ZNOL.02-27 III

¥1,080-3,888
SZTT OJSC 🇷🇺
Non-Grounded Voltage Transformers NOL.12-6(10) kV

Non-Grounded Voltage Transformers NOL.12-6(10) kV

¥648-2,592
SZTT OJSC 🇷🇺
Zero Sequence Current Transformers TZLM-110, 200

Zero Sequence Current Transformers TZLM-110, 200

¥648-2,160
SZTT OJSC 🇷🇺
Zero Sequence Current Transformers TЗЛК-O5.1

Zero Sequence Current Transformers TЗЛК-O5.1

¥648-2,592
SZTT OJSC 🇷🇺
Current Transformer for Measurement TSHL-0.66-III-4

Current Transformer for Measurement TSHL-0.66-III-4

¥648-2,592
SZTT OJSC 🇷🇺
Current Transformer TSHL-20-I for Signal Transmission

Current Transformer TSHL-20-I for Signal Transmission

¥648-2,592
SZTT OJSC 🇷🇺
Measuring Laboratory Current Transformers TLL-0.66

Measuring Laboratory Current Transformers TLL-0.66

¥648-2,592
SZTT OJSC 🇷🇺
Support-Through Current Transformers TL-10

Support-Through Current Transformers TL-10

¥216-1,296
SZTT OJSC 🇷🇺
Current Transformer for Signal Transmission TNSHL-0.66

Current Transformer for Signal Transmission TNSHL-0.66

¥648-4,320
SZTT OJSC 🇷🇺
Power Transformers TLS Series for Energy Supply

Power Transformers TLS Series for Energy Supply

¥64,800-432,000
SZTT OJSC 🇷🇺
Zero Sequence Current Transformers TЗЛМ-1

Zero Sequence Current Transformers TЗЛМ-1

¥648-2,592
SZTT OJSC 🇷🇺
Power Transformers TLS Series 25-400 kVA

Power Transformers TLS Series 25-400 kVA

¥43,200-432,000
SZTT OJSC 🇷🇺

常见问题

Can distribution transformers be built for my national grid parameters?
Yes. Plants wind to your primary and secondary voltages, vector group, tap range and frequency, and apply the cooling and climatic execution your site needs. Provide the network one-line data and ambient conditions; the factory returns a technical proposal with losses, impedance and dimensions for approval before production, which typically takes 8–16 weeks.
What testing documentation accompanies a transformer?
Every unit passes routine tests — winding resistance, ratio, insulation, applied and induced voltage, losses — documented in a protocol shipped with the transformer. Type test reports for the design are available for tender files. Utility buyers can witness factory acceptance in person or by video link, which suppliers arrange routinely.
How are lithium batteries and UPS systems shipped internationally?
Lithium-ion batteries travel as Class 9 dangerous goods: UN-certified packaging, state-of-charge limits and dangerous goods declarations, which suppliers prepare. Sea freight is the standard mode; air carries tighter restrictions. Lead-acid and VRLA batteries ship with simpler paperwork. Factor 1–2 extra weeks for DG documentation on first orders.
Do UPS suppliers help size the system for my facility?
Yes — send the load list, required autonomy and site temperature, and the supplier proposes UPS rating, battery configuration and ventilation requirements. For data-centre and telecom projects, redundancy schemes and monitoring integration are specified at this stage. Sizing calculations are part of the quotation, not a paid extra.
Is commissioning support available for packaged substations?
Packaged substations ship factory-assembled and tested, with installation and earthing drawings. Supervised commissioning by a factory engineer is a contract option many utility buyers take for the first units, then handle subsequent ones with their own crews. Remote support and spare-parts kits are agreed in the supply contract.
What payment structure is usual for large electrical equipment?
Typical terms are 30–50 percent advance with the balance before shipment by bank transfer; letters of credit are workable with larger plants if banking channels are agreed early. For framework utility contracts, milestone payments tied to factory acceptance tests are common practice.