产品 — 电源与配电

Lead-Acid Stationary Battery 12V 1200Ah (12GroE1200)

Lead-Acid Stationary Battery 12V 1200Ah (12GroE1200)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 16GroE1600

Lead Acid Stationary Battery 16GroE1600

¥1,080-3,024
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 22BП2200 (22GroE2200)

Lead Acid Stationary Battery 22BП2200 (22GroE2200)

¥1,080-3,456
KAZ LLC 🇷🇺
Stationary Lead Acid Battery 17Ah 17GroE425

Stationary Lead Acid Battery 17Ah 17GroE425

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 15BП375 (15GroE375)

Lead Acid Stationary Battery 15BП375 (15GroE375)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 17GroE1700

Lead Acid Stationary Battery 17GroE1700

¥1,080-3,024
KAZ LLC 🇷🇺
Stationary Lead Acid Battery 18BП450 (18GroE450)

Stationary Lead Acid Battery 18BП450 (18GroE450)

¥648-2,160
KAZ LLC 🇷🇺
Stationary Lead Acid Battery 3BП75 (3GroE75)

Stationary Lead Acid Battery 3BП75 (3GroE75)

¥259.20-864
KAZ LLC 🇷🇺
Stationary Lead Acid Battery 13BП325 (13GroE325)

Stationary Lead Acid Battery 13BП325 (13GroE325)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 20BП2000 (20GroE2000)

Lead Acid Stationary Battery 20BП2000 (20GroE2000)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 7BП175 (7GroE175)

Lead Acid Stationary Battery 7BП175 (7GroE175)

¥302.40-864
KAZ LLC 🇷🇺

发布您的采购需求

从认证供应商获取报价

节省时间
Stationary Lead-Acid Battery 14BП1400 (14GroE1400)

Stationary Lead-Acid Battery 14BП1400 (14GroE1400)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 15BП1500 (15GroE1500)

Lead Acid Stationary Battery 15BП1500 (15GroE1500)

¥1,080-3,024
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 9BП225 (9GroE225)

Lead Acid Stationary Battery 9BП225 (9GroE225)

¥648-2,160
KAZ LLC 🇷🇺
Lead Acid Stationary Battery 13BП1300 (13GroE1300)

Lead Acid Stationary Battery 13BП1300 (13GroE1300)

¥648-2,160
KAZ LLC 🇷🇺
Stationary Lead Acid Battery 9BП900 (9GroE900)

Stationary Lead Acid Battery 9BП900 (9GroE900)

¥648-2,160
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-110N(NR)

12V Lead-Acid Starter Battery 6ST-110N(NR)

¥151.20-388.80
KAZ LLC 🇷🇺
12V 60Ah Lead-Acid Starter Battery 6СТ-60L(LR)

12V 60Ah Lead-Acid Starter Battery 6СТ-60L(LR)

¥151.20-432
KAZ LLC 🇷🇺
Lead Acid Starter Battery 6СТ-60N(NR) for Cars

Lead Acid Starter Battery 6СТ-60N(NR) for Cars

¥108-302.40
KAZ LLC 🇷🇺
12V 77Ah Lead-Acid Starter Battery 6СТ-77L (LR)

12V 77Ah Lead-Acid Starter Battery 6СТ-77L (LR)

¥194.40-518.40
KAZ LLC 🇷🇺
Lead-Acid Starter Battery 6ST-62L (LR)

Lead-Acid Starter Battery 6ST-62L (LR)

¥151.20-432
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6СТ-77N (NR)

12V Lead-Acid Starter Battery 6СТ-77N (NR)

¥108-302.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-110L(LR)

12V Lead-Acid Starter Battery 6ST-110L(LR)

¥194.40-518.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 90Ah for Cars - 6ST-90L(LR)

12V Lead-Acid Starter Battery 90Ah for Cars - 6ST-90L(LR)

¥194.40-518.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-75N(NR)

12V Lead-Acid Starter Battery 6ST-75N(NR)

¥108-302.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-66L(LR)

12V Lead-Acid Starter Battery 6ST-66L(LR)

¥194.40-518.40
KAZ LLC 🇷🇺
12V 100Ah Lead-Acid Starter Battery for Cars 6СТ-100L(LR)

12V 100Ah Lead-Acid Starter Battery for Cars 6СТ-100L(LR)

¥194.40-518.40
KAZ LLC 🇷🇺
Lead Acid Starter Battery 6СТ-60N (A, AZ, AP)

Lead Acid Starter Battery 6СТ-60N (A, AZ, AP)

¥64.80-216
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 85Ah for Cars - 6ST-85L(LR)

12V Lead-Acid Starter Battery 85Ah for Cars - 6ST-85L(LR)

¥194.40-518.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-60VL(VLR)

12V Lead-Acid Starter Battery 6ST-60VL(VLR)

¥108-388.80
KAZ LLC 🇷🇺
Starter Lead-Acid Battery 6СТ-95N(NR) 12V 95Ah

Starter Lead-Acid Battery 6СТ-95N(NR) 12V 95Ah

¥108-302.40
KAZ LLC 🇷🇺
12V Lead-Acid Starter Battery 6ST-45N(NR)

12V Lead-Acid Starter Battery 6ST-45N(NR)

¥64.80-216
KAZ LLC 🇷🇺
Starter Lead-Acid Battery 6СТ-45L (LR)

Starter Lead-Acid Battery 6СТ-45L (LR)

¥108-302.40
KAZ LLC 🇷🇺

常见问题

Can distribution transformers be built for my national grid parameters?
Yes. Plants wind to your primary and secondary voltages, vector group, tap range and frequency, and apply the cooling and climatic execution your site needs. Provide the network one-line data and ambient conditions; the factory returns a technical proposal with losses, impedance and dimensions for approval before production, which typically takes 8–16 weeks.
What testing documentation accompanies a transformer?
Every unit passes routine tests — winding resistance, ratio, insulation, applied and induced voltage, losses — documented in a protocol shipped with the transformer. Type test reports for the design are available for tender files. Utility buyers can witness factory acceptance in person or by video link, which suppliers arrange routinely.
How are lithium batteries and UPS systems shipped internationally?
Lithium-ion batteries travel as Class 9 dangerous goods: UN-certified packaging, state-of-charge limits and dangerous goods declarations, which suppliers prepare. Sea freight is the standard mode; air carries tighter restrictions. Lead-acid and VRLA batteries ship with simpler paperwork. Factor 1–2 extra weeks for DG documentation on first orders.
Do UPS suppliers help size the system for my facility?
Yes — send the load list, required autonomy and site temperature, and the supplier proposes UPS rating, battery configuration and ventilation requirements. For data-centre and telecom projects, redundancy schemes and monitoring integration are specified at this stage. Sizing calculations are part of the quotation, not a paid extra.
Is commissioning support available for packaged substations?
Packaged substations ship factory-assembled and tested, with installation and earthing drawings. Supervised commissioning by a factory engineer is a contract option many utility buyers take for the first units, then handle subsequent ones with their own crews. Remote support and spare-parts kits are agreed in the supply contract.
What payment structure is usual for large electrical equipment?
Typical terms are 30–50 percent advance with the balance before shipment by bank transfer; letters of credit are workable with larger plants if banking channels are agreed early. For framework utility contracts, milestone payments tied to factory acceptance tests are common practice.