1
وصف الطلب
2
معلومات الاتصال

ماذا تحتاج؟

صف المنتج أو الخدمة التي تبحث عنها

معلومات الاتصال

سنتواصل معك في أقرب وقت ممكن

تم إرسال طلبك!

شكرًا لك! سنتواصل معك قريبًا مع أفضل العروض.

مجموعة تحديث التوربين T-100/120-130-2

مجموعة تحديث التوربين T-100/120-130-2

$300,000 - $1,800,000 USD
MOQ: 1 sets

الميزات الرئيسية

Minimum scope of modernization: Technical re-equipment of T-100/110-120 series turbine: life-saving units and parts operating at temperature more than 450C are replaced, which allows to renew the resource of the whole turbine, as well as to increase technical and economic indicators of t
Average volume of modernization: In addition to replacing life cycle components and parts of the high-pressure cylinder, additionally includes replacing worn out elements of the medium-pressure flow part, thereby improving the reliability of the medium-pressure part.
Maximum scope of modernization: In addition to the medium option, the worn elements of the low-pressure flow part are replaced to increase the reliability of the low-pressure part.

الوصف

Kit for technical re-equipment of steam turbine T-100/120-130-2 is designed for its modernisation with replacement of high-temperature units and parts that have exhausted their resource. Composition of the Kit: a new CVD complete, CVD stator flange and rotor with highly efficient blade profiles and developed overband seals, CVD seals (front, rear and diaphragm seals), Front Bearing Block complete, including. support liner, GMN and servo-motor VD, complete with foundation frame, support liner, control valves, stop valve block, VDC camshaft distributor, turbine cladding, set of pipelines for installation of the supplied equipment, as well as diaphragms of the 20th, 21st, 22nd and 23rd stages of DDC, ND servomotor, regulating diaphragms of the 24th and 26th stages of DDC, sets of working blades of the 24th and 26th stages of DDC to replace the corresponding units and parts of SD and ND having a high degree of wear

منتجات ذات صلة

High-Pressure Cylinder Upgrade Kit for T-100 Steam Turbine

مجموعة ترقية الأسطوانة ذات الضغط العالي لتوربين بخار T-100

$90,000-$600,000 USD
Minimum scope of modernization: modernisation of t-100 series turbine replace resource nodes and parts; operating at temperature more than 450°c. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
Minimum scope of modernization: modernisation of t-100 series turbine replace resource nodes and parts; operating at temperature more than 450°c. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
ش.م أورال 🇷🇺
Steam Turbine Upgrade Kit K-215-130-1M3 for CND Block #9

مجموعة ترقية التوربين البخاري K-215-130-1M3 لكتلة CND رقم 9

$90,000-$360,000 USD
Maximum steam flow rate through CND: 480
Nominal temperature of fresh steam upstream of CVD stop valves: 540
ش.م سيلوفي ماشيني 🇷🇺
Steam Turbine Modernization Kit T-100

مجموعة تحديث التوربين البخاري T-100

$60,000-$600,000 USD
Minimum scope of modernization: modernisation of turbine of t-100 series replace resource nodes and parts operating at temperature more than 450°?. it allows to renew resource, and also to increase nominal, maximum power and heat load in condensing mode.
Minimum scope of modernization: modernisation of turbine of t-100 series replace resource nodes and parts operating at temperature more than 450°?. it allows to renew resource, and also to increase nominal, maximum power and heat load in condensing mode.
ش.م أورال 🇷🇺
Complete Upgrade Kit for CND K-210(215)-12.8 Turbine Block

مجموعة تحديث لكتلة التوربين CND K-210(215)-12.8

$90,000-$360,000 USD
Rated power: 210
Maximum steam flow rate through CND: 480
ش.م سيلوفي ماشيني 🇷🇺
High-Pressure Turbine Cylinder Assembly for T-100-130 Upgrade

مجموعة أسطوانة التوربين عالي الضغط لترقية T-100-130

$90,000-$600,000 USD
Minimum scope of modernization: modernisation of t-100 series turbine replace resource nodes and parts; operating at temperature more than 450°c. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
Minimum scope of modernization: modernisation of t-100 series turbine replace resource nodes and parts; operating at temperature more than 450°c. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
ش.م أورال 🇷🇺
High-Pressure Cylinder Upgrade Kit for PT-60 Steam Turbine

مجموعة ترقية أسطوانة الضغط العالي لتوربين البخار PT-60

$90,000-$600,000 USD
Minimum scope of modernization: modernisation of turbine of series T-60 replace resource units and parts; operating at temperature more than 450°?. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
Minimum scope of modernization: modernisation of turbine of series T-60 replace resource units and parts; operating at temperature more than 450°?. it allows to renew resource; and also to increase nominal; maximum power and heat load in condensing mode.
ش.م أورال 🇷🇺
Steam Turbine Diaphragm 30 Stages Model 47T230-3219

غشاء توربين بخاري مكون من 30 مرحلة موديل 47T230-3219

$9,000-$30,000 USD
Overall dimensions (diameter): 2950
Overall dimensions (width): 420
ش.ذ.م.م القابضة تبلوإنيرغوسيرفيس 🇷🇺
Modular Vise PQ160 with Amplifier and Step Jaws Set BB.VS.160.11.002

فكي مودولار PQ160 مع مكبر ومجموعة من الشفاه المتدرجة BB.VS.160.11.002

$150-$420 USD
Jaw width: 160
Workpiece clamping force: 54000
ش.ذ.م.م أرموريكا 🇷🇺
Graphite Electrodes EGSP-UNP Diameter 520 mm and More 650 mm

أقطاب الجرافيت من نوع EGSP-UNP بقطر يصل إلى 520 مم وأكثر من 650 مم

$900-$3,000 USD
Diameter: 710
Length: 1500
ش.ذ.م.م إل 6 🇷🇺
Fountain Armature for Well Sealing (AFK)

أرماتور نافورة (AFK)

$9,000-$60,000 USD
Working pressure: 14...105
Material: alloy steel, corrosion-resistant alloy
ش.م أك كورفيت 🇷🇺
T-60/66-10.2 Steam Turbine - Single-Cylinder Design

توربينة البخار T-60/66-10.2 - تصميم أسطوانة واحدة

$900,000-$3,000,000 USD
Rated power: 66
Maximum heat load: 143
ش.م أورال 🇷🇺
Carbon Electrodes for Ferroalloy Production, Packaged, Size 762x914x3556

أقطاب كربونية لإنتاج الفيروأليوي - عبوة بحجم 762x914x3556

$90-$300 USD
Thermal conductivity, W/m*K: 80
Thermal conductivity, W/m*K: 80
ش.ذ.م.م إل 6 🇷🇺
Spot Welding Machine for Low Carbon Steel MT-801 UHL4

آلة لحام النقاط للصلب منخفض الكربون MT-801 UHL4

$900-$3,000 USD
Power: 60
Rated welding current: 8500
ش.م مصنع "فيرما سيلما 🇷🇺
Steam Turbine P-50-12.8/0.8

توربين بخاري P-50-12.8/0.8

$90,000-$360,000 USD
Fresh steam consumption: 330
Fresh steam pressure: 12.8
ش.م أورال 🇷🇺
Polishing Motor POLIR 6.4 OPTIMUM

آلة تلميع بولير 6.4 أوبتيموم

$900-$3,000 USD
Weight: 14
Power supply (without external hood): 220/230
ش.ذ.م.م فيغا - برو 🇷🇺
Carbon Mono-Electrodes 1205 mm for Ferrothermal Furnaces MUV-C

الأقطاب الكهربائية الكربونية أحادية 1205 ملم للاستخدام في الأفران الحرارية MUV-C

$900-$3,000 USD
Diameter: 1205
Ash content: 2.5
ش.ذ.م.م إل 6 🇷🇺
Stator Section Kit for Electric Motor A-114-4 (320kW, 6000V, 1480 RPM) RESIN Technology

مجموعة أقسام القلب الثابت للمحرك الكهربائي A-114-4 (قوة 320 كيلو واط، جهد 6000 فولت، سرعة 1480 دورة في الدقيقة)

$900-$3,600 USD
Section length: 900
Section width: 319
ش.ذ.م.م رإم إند كويل 🇷🇺
Wellhead Equipment Type ANK for Sealing and Control

معدات رأس البئر من نوع ANK للتسرب والتحكم

$3,000-$18,000 USD
Working pressure: 70
nominal passage: 150
ش.ذ.م.م مصنع المعدات النفطية والغازية "تخنوفيك 🇷🇺
Stator Section Set for Electric Motor FVEZ909714

مجموعة أقسام الستاتور لمحرك كهربائي FVEZ909714

$3,000-$18,000 USD
Section length: 1700
Section width: 262
ش.ذ.م.م رإم إند كويل 🇷🇺
Stator Winding Section Kit for Electric Motor 6A355M4

مجموعة أقسام لفائف الجزء الثابت لمحرك كهربائي 6A355M4

$900-$3,000 USD
Section length: 945
Section width: 270
ش.ذ.م.م رإم إند كويل 🇷🇺
طلب عبر واتساب