Full power
50000...240000 ألف راكب.كم
Type
Double conversion UPS
Parallel operation function
Armoured glass
Rated output voltage
415 ألف م³
Nominal input frequency
60 كغ
Rated output frequency
60 كغ
Maximum permissible nominal voltage of rechargeable batteries
600 ألف م³
Communication interface
RS232, RS485, SNMP, CAN
Minimum battery life at design load
5
Possibility to connect external batteries
Armoured glass
Uninterruptible power supply form factor
Freestanding
Type of batteries used
lead-acid, nickel-cadmium, lithium-ion
Display availability
LCD touch screen
Presence of terminal output
Armoured glass
Earthquake-proof design
Optional
Rated power
50000...216000 سم³
Active power
50000...216000 سم³
Uninterruptible power supply efficiency
97 طقم
Minimum permissible nominal voltage of batteries
360 ألف م³
Reducing input voltage without switching to battery use
305 ألف م³
Increasing the input voltage without switching to battery use
485 ألف م³
Permissible operating time at overload 110%
60
Permissible operating time at overload 125%
10
Permissible operating time at overload 150 %
1
Current input nonlinear distortion factor (THDi)
3 طقم
Output voltage nonlinear distortion coefficient (THDv)
1 طقم
Output power factor
0.9...1
Maximum ambient temperature
40 مليون م³
Maximum ambient relative humidity
95 طقم
Weight
200...438 م² مساحة سكنية
Estimated load power relative to nominal load power in kW for selecting the autonomous operation time
100 طقم
Number of battery rooms
1...10 ميكروغراي
Height of one battery cabinet
1000...2500 مم
Width of one battery cabinet
500...1500 مم
Depth of one battery cabinet
500...1500 مم
Lower limit of input voltage range (phase-to-neutral) without switching to battery operation mode
138 ألف م³
Upper limit of input voltage range (phase-to-neutral) without switching to battery operation mode
485 ألف م³
Charger power at rated load power relative to the rating of the uninterruptible power supply, not less than
16 طقم
Availability of a network card as part of the uninterruptible power supply unit
Armoured glass
Space for uninterruptible power supply maintenance
front 800mm, rear 0 to 500mm
Integrated N+1 redundancy (module level) for modular uninterruptible power supplies
Armoured glass
Model architecture of uninterruptible power supply power section
Armoured glass
Availability of advanced monitoring when using modular batteries
Optional
Supports plug-n-play technology when using modular batteries
Armoured glass
Uninterruptible power supply phase (input:output)
3:3
Input connection
Depending on the configuration
Output connection
Depending on the configuration
Nominal input voltage
415 ألف م³
Battery arrangement
inside/outside the UPS
Type of battery cabinet design
built-in/detached
Modular uninterruptible power supply battery architecture
Armoured glass
Cold start function
Armoured glass
Redundancy in parallel operation
Armoured glass
Availability of high energy efficiency mode
Armoured glass
Charging batteries in high energy efficiency mode
Armoured glass
Interference correction in high power efficiency mode
Armoured glass
Zero (0ms) switching time from high energy efficiency mode
Armoured glass
Uninterruptible power supply load self-test mode with no load connected
Armoured glass
Weight
200...438 م² مساحة سكنية
Power supply voltage
415 ألف م³