Addressable Output Module AMC-IP30
US$9-36
Degree of protection of the shell, IP:
30
External power supply voltage:
10...30
NITP NITA LLC 🇷🇺
Signal Switch for Metal Shavings Detection in Oil Systems VS-1T
US$9-36
Voltage drop on leads, mV, not more:
Flat grinder, Specialised grinder
Weight, g, not more:
95
ELECTROAVTOMAT OJSC 🇷🇺
Addressable Expansion Module for Non-Addressable Sensors - S2000-AR1 Version 03
US$9-30
Degree of protection of the shell:
IP68
Operating temperature range:
-45...55
BOLID CJSC 🇷🇺
Addressable Signal-Starting Block "C2000-SP2" ACDR.425412.004
US$15-48
Overall dimensions of the unit:
102×107×39 mm
Overall dimensions of the unit:
102×107×39 mm
BOLID CJSC 🇷🇺
Addressable Expander for Non-Addressable Detectors S2000-AR1 Version 02 ACDR.426461.001-02
US$9-30
Power supply voltage:
8...11
Number of monitored inputs:
1
BOLID CJSC 🇷🇺
Addressable Signal Expander for 8 Zones - S2000-AP8 ACDR.426461.003
US$15-42
Number of circuits to be monitored:
8
Power supply voltage:
8...11
BOLID CJSC 🇷🇺
Addressable Zone Expander for Alarm System S2000-AP1 Version 04
US$9-30
Power supply voltage:
8...11
Operating temperature range:
-30...55
BOLID CJSC 🇷🇺
Addressable Zone Expander for Alarm Systems S2000-AP1 Version 01
US$9-30
Power supply voltage:
8...11
Operating temperature range:
-30...55
BOLID CJSC 🇷🇺
DAP-IP SONAR SNCA-8002 Converter for Fire Alarm Systems
US$150-480
Operating temperature range:
0...40
External power supply voltage:
20.4...26.4
IMPULSE LLC 🇷🇺
Address Marker AM4-R2 for Fire Alarm Systems
US$9-30
Degree of protection of the shell, IP:
IP 20
Degree of protection of the shell, IP:
IP 20
IMPULSE LLC 🇷🇺
Address Tag AMP-10-R3 for Fire and Security Systems
US$9-30
Consumption current at 12 V power supply, mA:
10.5...30
Operating temperature range:
-25...55
IMPULSE LLC 🇷🇺
Eridan Address Label for Fire Alarm MAE-T-R2
US$1.80-7.20
Degree of protection of the shell, IP:
IP 67
Degree of protection of the shell, IP:
IP 67
IMPULSE LLC 🇷🇺
Address Label AM-1-R3 for Dry Contact Devices
US$9-30
Degree of protection of the shell, IP:
IP 20
Degree of protection of the shell, IP:
IP 20
IMPULSE LLC 🇷🇺
Fire Address Marker AMP4-R2 for Alarm Systems
US$9-30
Housing material:
ABS
Power supply voltage:
10,5 - 28
IMPULSE LLC 🇷🇺
MI-R2 Isolation Module for Address Line Control
US$9-36
Degree of protection of the shell, IP:
IP 20
Degree of protection of the shell, IP:
IP 20
IMPULSE LLC 🇷🇺
Fire Alarm System Isolator IZ-1-R3
US$1.80-6
Degree of protection of the shell, IP:
IP 20
Degree of protection of the shell, IP:
IP 20
IMPULSE LLC 🇷🇺
Smoke Extraction Automation Module MDU-R2 Version 220
US$15-48
External power supply voltage:
230
Operating temperature range:
-20...70
IMPULSE LLC 🇷🇺
Smoke Removal Automation Module MDU-1-R3
US$15-60
External power supply voltage:
24
Operating temperature range:
-25...55
IMPULSE LLC 🇷🇺
Alarm Signal Loop Network Controller SКШС-01 Version P
US$90-300
Number of loops:
4
DC supply voltage:
10...28
RISPA LLC 🇷🇺
Network Controller for Alarm Loops SКШС-03-4 IP20
US$90-300
Number of loops:
4
Communication interface with the BCU:
RS485
RISPA LLC 🇷🇺
Network Alarm Loop Controller SKSHS-01 IP20
US$15-48
Number of loops:
4
Communication interface with the BCU:
RS485
RISPA LLC 🇷🇺
Short Circuit Isolation Module MKZ Version 08
US$9-36
Power supply:
From the addressable loop
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Executive Module ISM-220 version 08-4
US$15-48
Switchable output AC voltage range:
160...260
Operating temperature range:
-10...55
RISPA LLC 🇷🇺
Addressable Executive Module ISM-22 Version 08-1
US$9-36
Power supply:
From the addressable loop
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Executive Module ISM-22 Version 08-2
US$9-36
Power supply:
From the addressable loop
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Control Module ISM22 Version 1
US$9-30
Number of relay outputs with NC and NC contacts:
2
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Expander AR5 Version 08 for 5 Non-Addressable Loops
US$9-36
Consumption current in the "Loop 3 On" mode (or when the indicator is on) , not more than mA:
10
Consumption current in the "Loop 3 On" mode (or when the indicator is on) , not more than mA:
10
RISPA LLC 🇷🇺
Addressable Expander ARmini Model 08
US$1.80-9.60
Number of connected addressless alarm loops:
2
Operating temperature range:
-40...60
RISPA LLC 🇷🇺
Addressable Expander AR1 Version 08 - Connects 1 Non-Addressable Loop
US$3-18
Maximum voltage in an unaddressed alarm loop, not more than:
15
Consumption current , not more, mA:
3
RISPA LLC 🇷🇺
Addressable Expander AR1
US$0.90-3.60
Consumption current , max.:
3 mA
Consumption current , max.:
3 mA
RISPA LLC 🇷🇺
Addressable Expander ARmini model P for ASB Rubicon
US$9-30
Number of connected unaddressed alarm loops:
2
Operating temperature range:
-40...60
RISPA LLC 🇷🇺
Addressable Expander AR5 for 5 Loops
US$9-30
Consumption current in the "Loop 3 on" mode (or when the indicator is on) , not more than:
10 mA
Consumption current in the "Loop 3 on" mode (or when the indicator is on) , not more than:
10 mA
RISPA LLC 🇷🇺
Addressable Expander AРмини for Connecting Non-addressable Detectors
US$1.20-6
Number of connected unaddressed alarm loops:
2
Operating temperature range:
-40...60
RISPA LLC 🇷🇺
Universal Fire Alarm Interface Module IFA-164
US$90-300
Number of notification directions:
64
Overall dimensions, mm:
190x138x40
INTELLECT SECURITY LLC 🇷🇺
Universal Fire Alarm Interface Block IFA-108
US$90-300
Number of notification directions:
64
Overall dimensions, mm:
190x138x40
INTELLECT SECURITY LLC 🇷🇺
Fire Alarm Integration Module Rubezh IFA-001
US$90-300
Maximum number of fire alarm directions:
64
Overall dimensions, mm:
90x50x32
INTELLECT SECURITY LLC 🇷🇺
Fire Alarm Interface Module Bolid IFA-002 for 64 Zones
US$90-300
Number of notification directions:
64
Overall dimensions, mm:
90x50x32
INTELLECT SECURITY LLC 🇷🇺
Signal Switch Emsok MSS-2600 for Fire Alarm Systems
US$150-480
Number of switched outputs:
8
Control signal data transmission standard:
RS - 485
INTELLECT SECURITY LLC 🇷🇺
Short Circuit Insulator IKZ - IP56 Rated
US$1.50-6
Degree of protection of the shell, IP:
56
Degree of protection of the shell, IP:
56
MRS ELECTRONICS LLC 🇷🇺
Fire Alarm Control and Monitoring Module UPKOP 135-1-1 (BIV Version V6)
US$90-300
Assignment:
for monitoring and re-inquiry of the state of one intrinsically safe fire and (or) intrinsically safe fire and (or) intrusion alarm loop (FIR)
Assignment:
for monitoring and re-inquiry of the state of one intrinsically safe fire and (or) intrinsically safe fire and (or) intrusion alarm loop (FIR)
CJSC "PO "SPETSAVTOMATIKA" 🇷🇺
Liquid Flow Alarm Stream v3.2 for Fire Protection
US$90-300
Dimensions:
165x80x130
Response time:
2
CJSC "PO "SPETSAVTOMATIKA" 🇷🇺
Signal Line Block for Fire and Security System SPK-BSL
US$42-150
Overall dimensions:
210x143x38 mm
Weight:
0.4 kg
ARGUS-SPEKTR LLC 🇷🇺
Signal Line Block BSL240-I for Security Systems
US$90-300
Overall dimensions:
210×143×38
Operating temperature range:
-30...55
ARGUS-SPEKTR LLC 🇷🇺
Addressable Remote Start Device SPK-MAX-UDP-DU
US$9-36
Overall dimensions of the device:
118x106x49 mm.
Degree of protection of the device shell:
IP41
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Block SPK-IB1 for Fire Safety Systems
US$15-60
Overall dimensions:
210x143x38 mm
Maximum switching current:
8 ?
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Block SPK-MAX-DU220
US$15-48
Overall dimensions of the device:
210x143x38 mm
Degree of protection of the device shell:
IP41
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Block SPK-MAX-IB1 for Fire Safety
US$30-96
Overall dimensions of the device:
210x143x38 mm
Device weight:
360
ARGUS-SPEKTR LLC 🇷🇺