AMK-IP30 Addressable Input/Output Module
US$15-48
Degree of protection of the shell, IP:
30
Structural design:
Metal enclosure for wall mounting
NITP NITA LLC 🇷🇺
Linear Module for Automatic Fire Detection and Suppression System - LM-ASOTP-G DTGA.425529.015
US$90-300
Power consumption:
5
Width:
200
METROSPETS TECHNICA LLC 🇷🇺
Remote Start Device for Smoke Removal RUBETEK UDP-513-102D
US$15-48
Dimensions (L x W x H), mm:
85x85x40
Degree of enclosure protection:
IP20
RUBETEK RUS LLC 🇷🇺
Addressable Remote Start Device SPK-MAX-UDP-DU
US$9-36
Overall dimensions of the device:
118x106x49 mm.
Degree of protection of the device shell:
IP41
ARGUS-SPEKTR LLC 🇷🇺
Addressable Expansion Module for Non-Addressable Sensors - S2000-AR1 Version 03
US$9-30
Degree of protection of the shell:
IP68
Operating temperature range:
-45...55
BOLID CJSC 🇷🇺
Address Module AMZ-NC-IP30 for Vesta 01F System
US$3-18
Degree of protection of the shell, IP:
30
Structural design:
Plastic case
NITP NITA LLC 🇷🇺
Address Expansion Module AMR-4 "RUBETEK
US$15-48
Number of monitored loops with detectors:
4
Number of outputs with line open-circuit and short-circuit monitoring:
4
RUBETEK RUS LLC 🇷🇺
Addressable Signal-Starting Block "C2000-SP2" ACDR.425412.004
US$15-48
Overall dimensions of the unit:
102×107×39 mm
Overall dimensions of the unit:
102×107×39 mm
BOLID CJSC 🇷🇺
Addressable Executive Block SPK-IB1 for Fire Safety Systems
US$15-60
Overall dimensions:
210x143x38 mm
Maximum switching current:
8 ?
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Block SPK-MAX-DU220
US$15-48
Overall dimensions of the device:
210x143x38 mm
Degree of protection of the device shell:
IP41
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Block SPK-MAX-IB1 for Fire Safety
US$30-96
Overall dimensions of the device:
210x143x38 mm
Device weight:
360
ARGUS-SPEKTR LLC 🇷🇺
Liquid Flow Alarm Stream v3.2 for Fire Protection
US$90-300
Dimensions:
165x80x130
Response time:
2
CJSC "PO "SPETSAVTOMATIKA" 🇷🇺
Post your Buy Requirement
Get Quotes from Verified Suppliers
Save Your Time
Signal Switch for Metal Shavings Detection in Oil Systems VS-1T
US$9-36
Voltage drop on leads, mV, not more:
Flat grinder, Specialised grinder
Weight, g, not more:
95
ELECTROAVTOMAT OJSC 🇷🇺
Signal Switch Emsok MSS-2600 for Fire Alarm Systems
US$150-480
Number of switched outputs:
8
Control signal data transmission standard:
RS - 485
INTELLECT SECURITY LLC 🇷🇺
Addressable Executive Control Unit SPK-MAX-DU24
US$15-48
Overall dimensions of the device:
210x143x38 mm
Device weight:
450
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Unit SPK-DU220
US$15-60
Overall dimensions:
210x143x38 mm
Rated switching voltage:
220 ?
ARGUS-SPEKTR LLC 🇷🇺
Addressable Actuator Block SPK-DU24
US$15-48
Overall dimensions:
210x143x38 mm
Rated switching voltage:
24 ?
ARGUS-SPEKTR LLC 🇷🇺
Addressable Executive Module ISM-220 version 08-4
US$15-48
Switchable output AC voltage range:
160...260
Operating temperature range:
-10...55
RISPA LLC 🇷🇺
Addressable Control Module AKOR-U Version 4
US$9-36
Number of relay outputs:
4
Module informativeness:
3 ("Normal", "Control Fault (No load power supply/ Control open circuit)", "No communication")
RUSSBYT LLC 🇷🇺
Addressable Executive Module ISM-22 Version 08-1
US$9-36
Power supply:
From the addressable loop
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Control Module AKOR-U Version 2
US$9-36
Number of relay outputs:
2
Module informativeness:
3 ("Normal", "Control fault (No load power supply/ Control circuit breakdown)", "No communication")
RUSSBYT LLC 🇷🇺
Addressable Module AKOR-U4 for Fire Automation Control
US$9-36
Module informativeness:
9 ("Normal", "Message 1", "Message 2", "Relay Fault", "Relay ON", "Control Fault (No load power supply/ Control open circuit)", "Loop open circuit", "Loop short circuit" , "No communication"), "No communication". , "No communication")
Module informativeness:
9 ("Normal", "Message 1", "Message 2", "Relay Fault", "Relay ON", "Control Fault (No load power supply/ Control open circuit)", "Loop open circuit", "Loop short circuit" , "No communication"), "No communication". , "No communication")
RUSSBYT LLC 🇷🇺
Addressable Executive Module ISM-22 Version 08-2
US$9-36
Power supply:
From the addressable loop
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Control Module ISM22 Version 1
US$9-30
Number of relay outputs with NC and NC contacts:
2
Power supply:
From the addressable loop
RISPA LLC 🇷🇺
Addressable Module AKOR-UOP-V for Alarm Systems
US$9-30
Overall dimensions, not more:
75x55x33
Module supply voltage:
10 ÷ 28
RUSSBYT LLC 🇷🇺
Addressable Control Module for Fire Automation AKOR-UOP
US$9-36
Overall dimensions, not more:
75x55x33
Module supply voltage:
9 ÷ 28
RUSSBYT LLC 🇷🇺
RUBETEK MK-4 Communication Module for Fire Alarm Systems
US$9-30
Dimensions (L x W x H), mm:
97,5 x 50 x 32
Maximum operating voltage:
230
RUBETEK RUS LLC 🇷🇺
RUBETEK MK-2 Switching Module for Control Cabinets
US$1.20-6
Overall dimensions:
20
Maximum load current:
7,5
ZAVOD PRIBOROV LLC 🇷🇺
RUBETEK MK-4 Switching Module for Fire Valves and Control Cabinets
US$9-36
Overall dimensions:
97.5
Maximum switched current:
2
ZAVOD PRIBOROV LLC 🇷🇺
Fire Alarm Signal Module MК-1 "RUBETEK
US$1.20-6
Dimensions (L x W x H), mm:
20x10x4
Maximum load current:
1
RUBETEK RUS LLC 🇷🇺
RUBETEK MK-2 Connection Module for Control Cabinets
US$3-18
Dimensions (L x W x H), mm:
20x10x4
Degree of protection:
IP30
RUBETEK RUS LLC 🇷🇺
RUBETEK MK-6 Switching Module for Fire Alarm Systems
US$9-36
Number of SC control outputs:
2
Number of inputs for connection of SCs:
3
ZAVOD PRIBOROV LLC 🇷🇺
RUBETEK MK-6 Communication Module for Fire Alarm Systems
US$9-30
Dimensions (L x W x H), mm:
115x93x40
Number of dry contact outputs:
1
RUBETEK RUS LLC 🇷🇺
Smoke Extraction Automation Modules MDU-1 Pro R3, MDU-1S Pro R3
US$15-48
Overall dimensions of the module, mm:
108×170×42
Overall dimensions of the module, mm:
108×170×42
KB POZHARNOY AVTOMATIKI LLC 🇷🇺
Smoke Extraction Automation Module MDU-R2 Version 24
US$90-300
Operating temperature range:
-20...70
External power supply voltage:
20...28
RUBEZH LLC 🇷🇺
Addressable Radio Channel Smoke Removal Module MDA-R
US$90-300
Overall dimensions:
41
Supply voltage of the PCB actuators:
220...230
ZAVOD PRIBOROV LLC 🇷🇺
Smoke Removal Automation Module MDU-R2 220V
US$15-60
Overall dimensions, mm:
150x105x41
Overall dimensions, mm:
150x105x41
KB POZHARNOY AVTOMATIKI LLC 🇷🇺
Smoke Extraction Automation Module MDU-R2 Version 220
US$15-48
External power supply voltage:
230
Operating temperature range:
-20...70
IMPULSE LLC 🇷🇺
Smoke Extraction Automation Module MDU-R2 Version 220
US$90-300
External power supply voltage:
230
Degree of protection of the shell, IP:
IP20
RUBEZH LLC 🇷🇺
Smoke Removal Automation Module MDU-1-R3
US$15-60
External power supply voltage:
24
Operating temperature range:
-25...55
IMPULSE LLC 🇷🇺
Addressable Combined Smoke Removal Module MDA-101-3 "RUBETEK
US$90-300
Dimensions (L x W x H), mm:
160x125x36
Number of remote control valves, OPC valves controlled by the module:
3
RUBETEK RUS LLC 🇷🇺
Addressable Expander for Non-Addressable Detectors S2000-AR1 Version 02 ACDR.426461.001-02
US$9-30
Power supply voltage:
8...11
Number of monitored inputs:
1
BOLID CJSC 🇷🇺
Addressable Expander AR-1 "RUBETEK
US$9-36
Dimensions (L x W x H), mm:
40x56x20
Number of address slots occupied:
1
RUBETEK RUS LLC 🇷🇺
Addressable Signal Expander for 8 Zones - S2000-AP8 ACDR.426461.003
US$15-42
Number of circuits to be monitored:
8
Power supply voltage:
8...11
BOLID CJSC 🇷🇺
Addressable Expander AR5 Version 08 for 5 Non-Addressable Loops
US$9-36
Consumption current in the "Loop 3 On" mode (or when the indicator is on) , not more than mA:
10
Consumption current in the "Loop 3 On" mode (or when the indicator is on) , not more than mA:
10
RISPA LLC 🇷🇺
Addressable Expander ARmini Model 08
US$1.80-9.60
Number of connected addressless alarm loops:
2
Operating temperature range:
-40...60
RISPA LLC 🇷🇺
Addressable Expander AR1 Version 08 - Connects 1 Non-Addressable Loop
US$3-18
Maximum voltage in an unaddressed alarm loop, not more than:
15
Consumption current , not more, mA:
3
RISPA LLC 🇷🇺